Session aimMachine conditioning
Session day2009-02-03Operatorpduarte
Session IDISTTOK_200923_1Coordinatorpduarte

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
210892009-02-03 16:13:35.165pduarte4.73.83340 turns primary. R = 0,2ohm. ELCO = 170V. P=2,10x10^(-4)mbar. Pre-Programmed H and V field.
210882009-02-03 16:05:31.303pduarte4.743340 turns primary. R = 0,2ohm. ELCO = 170V. P=2,00x10^(-4)mbar. Pre-Programmed H and V field.
210872009-02-03 15:56:44.657pduarte4.543340 turns primary. R = 0,2ohm. ELCO = 170V. P=2,00x10^(-4)mbar. Pre-Programmed H and V field.
210862009-02-03 15:49:06.108pduarte4.93.63340 turns primary. R = 0,2ohm. ELCO = 170V. P=2,00x10^(-4)mbar. Pre-Programmed H and V field.
210852009-02-03 15:36:01.02pduarte53.73340 turns primary. R = 0,2ohm. ELCO = 170V. P=2,00x10^(-4)mbar. Pre-Programmed H and V field.
210842009-02-03 15:25:23.004pduarte4.53.54440 turns primary. R = 0,2ohm. ELCO = 170V. P=2,00x10^(-4)mbar. Pre-Programmed H and V field.
210832009-02-03 15:18:34.084pduarte4.93.54440 turns primary. R = 0,2ohm. ELCO = 170V. P=2,00x10^(-4)mbar. Pre-Programmed H and V field.
210822009-02-03 15:08:30.849pduarte4.53.54440 turns primary. R = 0,2ohm. ELCO = 170V. P=1,80x10^(-4)mbar. Pre-Programmed H and V field.
210812009-02-03 14:53:38.099pduarte4.73.64440 turns primary. R = 0,2ohm. ELCO = 170V. P=1,80x10^(-4)mbar. Pre-Programmed H and V field.
210802009-02-03 14:41:15.079pduarte4.53.54440 turns primary. R = 0,2ohm. ELCO = 170V. P=1,70x10^(-4)mbar. Pre-Programmed H and V field.
210792009-02-03 14:29:28.088pduarte4.33.73340 turns primary. R = 0,2ohm. ELCO = 170V. P=1,70x10^(-4)mbar. Pre-Programmed H and V field.
210782009-02-03 14:23:09.111pduarte000PRECO failure
210772009-02-03 14:14:25.644pduarte4.23.56140 turns primary. R = 0,2ohm. ELCO = 170V. P=1,70x10^(-4)mbar. Pre-Programmed H and V field.
210762009-02-03 14:07:47.85pduarte3.533340 turns primary. R = 0,2ohm. ELCO = 170V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field.
210752009-02-03 14:00:14.001pduarte22.26140 turns primary. R = 0,2ohm. ELCO = 170V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field.