| 21729 | 2009-03-19 17:25:52.029 | pduarte | 3.7 | 2.7 | 26 | 40 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=60. IVERT=160A. PMs in laser room. batteries protection. fiber 4 disconnected. FD on tech 4. |
| 21728 | 2009-03-19 17:13:58.645 | pduarte | 3.7 | 2.8 | 67 | 40 turns primary. R = 0,4ohm. ELCO = 200V. P=1,0x10^(-4)mbar. Pre-Programmed H and V field. CHERENKOV=60. IVERT=160A. PMs in laser room. batteries protection. cherenkov 4 with FD. |
| 21727 | 2009-03-19 17:08:03.222 | pduarte | 0 | 0 | 1 | ELCO circuit breaker failure |
| 21726 | 2009-03-19 16:51:46.47 | pduarte | 3.7 | 2.8 | 26 | 40 turns primary. R = 0,4ohm. ELCO = 200V. P=1,0x10^(-4)mbar. Pre-Programmed H and V field. CHERENKOV=60. IVERT=160A. PMs in laser room. batteries protection. FD on tech 4 without fiberoptic |
| 21725 | 2009-03-19 16:44:27.031 | pduarte | 4 | 2.7 | 26 | 40 turns primary. R = 0,4ohm. ELCO = 200V. P=1,0x10^(-4)mbar. Pre-Programmed H and V field. CHERENKOV=65. IVERT=160A. PMs in laser room. batteries protection |
| 21724 | 2009-03-19 16:38:11.587 | pduarte | 4 | 2.6 | 26 | 40 turns primary. R = 0,4ohm. ELCO = 200V. P=1,0x10^(-4)mbar. Pre-Programmed H and V field. CHERENKOV=70. IVERT=160A. PMs in laser room. batteries protection |
| 21723 | 2009-03-19 16:28:02.267 | pduarte | 4 | 3 | 35 | 40 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=90. IVERT=160A. PMs in laser room. fiber1 disconnected in detector. batteries protection |
| 21722 | 2009-03-19 16:19:54.14 | pduarte | 4 | 3 | 35 | 40 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=90. IVERT=160A. PMs in laser room. batteries protection |
| 21721 | 2009-03-19 16:13:05.272 | pduarte | 3.9 | 2.9 | 26 | 40 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=85. IVERT=160A. PMs in laser room. batteries protection |
| 21720 | 2009-03-19 16:06:52.817 | pduarte | 3.4 | 1.8 | 26 | 40 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=55. IVERT=160A. PMs in laser room. batteries protection |
| 21719 | 2009-03-19 15:59:08.27 | pduarte | 3.4 | 1.9 | 26 | 40 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=55. IVERT=160A. PMs in laser room. batteries protection |
| 21718 | 2009-03-19 15:51:09.268 | pduarte | 3.4 | 2.2 | 26 | 40 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=60. IVERT=160A. PMs in laser room. batteries protection |
| 21717 | 2009-03-19 15:45:34.368 | pduarte | 0 | 0 | 1 | ELCO circuit breaker failure. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=60. IVERT=160A. PMs in laser room. batteries protection |
| 21716 | 2009-03-19 15:38:40.448 | pduarte | 3.5 | 2 | 26 | 40 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=60. IVERT=160A. PMs in laser room. batteries protection |
| 21715 | 2009-03-19 15:31:29.216 | pduarte | 3.8 | 2 | 50 | 40 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=65. IVERT=160A. PMs in laser room. batteries protection |
| 21714 | 2009-03-19 15:24:52.36 | pduarte | 3.9 | 2 | 26 | 40 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=65. IVERT=160A. PMs in laser room. batteries protection |
| 21713 | 2009-03-19 15:18:24.734 | pduarte | 4 | 2.7 | 50 | 40 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=70. IVERT=160A. PMs in laser room. batteries protection |
| 21712 | 2009-03-19 15:10:49.479 | pduarte | 0 | 0 | 1 | ELCO circuit breaker failure. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=70. IVERT=160A. PMs in laser room. batteries protection |
| 21711 | 2009-03-19 15:02:46.881 | pduarte | 4 | 2.5 | 50 | 40 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=70. IVERT=160A. PMs in laser room. batteries protection |
| 21710 | 2009-03-19 14:57:08.877 | pduarte | 4 | 3 | 50 | 40 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=75. IVERT=160A. PMs in laser room. batteries protection |
| 21709 | 2009-03-19 14:51:17.722 | pduarte | 4 | 3 | 45 | 40 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=75. IVERT=160A. PMs in laser room. batteries protection |
| 21708 | 2009-03-19 14:45:23.50 | pduarte | 4 | 3 | 36 | 40 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=80. IVERT=160A. PMs in laser room. batteries protection |
| 21707 | 2009-03-19 14:39:15.912 | pduarte | 4 | 3 | 36 | 40 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=80. IVERT=160A. PMs in laser room. batteries protection |
| 21706 | 2009-03-19 14:33:48.169 | pduarte | 4 | 3 | 36 | 40 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=85. IVERT=160A. PMs in laser room. batteries protection |
| 21705 | 2009-03-19 14:26:31.687 | pduarte | -3.5 | 1.5 | 10 | PRECO Failure. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=85. IVERT=160A. PMs in laser room. batteries protection |
| 21704 | 2009-03-19 14:13:03.526 | pduarte | 4 | 3 | 36 | 40 turns primary. R = 0,4ohm. ELCO = 200V. P=8,0x10^(-5)mbar. Pre-Programmed H and V field. IVERT=160A. |
| 21703 | 2009-03-19 12:57:18.042 | pduarte | 4 | 3 | 50 | 40 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=100. IVERT=160A. PMs in laser room. fiber 1 off in the detector. batteries protection |
| 21702 | 2009-03-19 12:50:20.559 | pduarte | 4 | 2.8 | 50 | 40 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=70. IVERT=160A. PMs in laser room. fiber 1 off in the detector. batteries protection |
| 21701 | 2009-03-19 12:44:53.853 | pduarte | 0 | 0 | 1 | ELCO circuit breaker failure |
| 21700 | 2009-03-19 12:38:58.207 | pduarte | 4 | 3 | 50 | 40 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=85. IVERT=160A. PMs in laser room. fiber 1 off in the detector. batteries protection |
| 21699 | 2009-03-19 12:33:09.713 | pduarte | 4 | 3 | 50 | 40 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=90. IVERT=160A. PMs in laser room. fiber 1 off in the detector. batteries protection |
| 21698 | 2009-03-19 12:25:24.726 | pduarte | 4 | 3 | 50 | 40 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=90. IVERT=160A. PMs in laser room. fiber 1 off in the detector. batteries protection |
| 21697 | 2009-03-19 12:11:49.876 | pduarte | 3.9 | 2.5 | 50 | 40 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=60. IVERT=160A. PMs in laser room. fiber 1 disconnected in the detector |
| 21696 | 2009-03-19 12:00:35.25 | pduarte | 3.8 | 2.6 | 50 | 40 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=60. IVERT=160A. PMs in laser room. fiber 1 disconnected in the detector |
| 21695 | 2009-03-19 11:54:22.112 | pduarte | 4 | 3 | 50 | 40 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=70. IVERT=160A. PMs in laser room. fiber 1 disconnected in the detector |
| 21694 | 2009-03-19 11:39:38.108 | pduarte | 4 | 3 | 50 | 40 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=80. IVERT=160A. PMs in laser room. fiber 1 disconnected in the PM |
| 21693 | 2009-03-19 11:31:44.27 | pduarte | 4 | 3 | 50 | 40 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=80. IVERT=160A. PMs in laser room. fiber 1 OFF |
| 21692 | 2009-03-19 11:25:40.323 | pduarte | 0 | 0 | 1 | ELCO circuit breaker failure. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=80. IVERT=160A. PMs in laser room. fiber 1 OFF |
| 21691 | 2009-03-19 11:17:06.06 | pduarte | 4 | 3 | 50 | 40 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=80. IVERT=160A. PMs in laser room |
| 21690 | 2009-03-19 11:09:28.907 | pduarte | 4 | 3 | 50 | 40 turns primary. R = 0,4ohm. ELCO = 200V. P=8,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=325. IVERT=160A. PMs in laser room |
| 21689 | 2009-03-19 11:03:56.273 | pduarte | 3.5 | 2.5 | 50 | 40 turns primary. R = 0,4ohm. ELCO = 200V. P=8,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=325. IVERT=120A. PMs in laser room |
| 21688 | 2009-03-19 10:57:39.417 | pduarte | 2 | 2.6 | 50 | 40 turns primary. R = 0,4ohm. ELCO = 200V. P=1,0x10^(-4)mbar. Pre-Programmed H and V field. CHERENKOV=325. IVERT=80A. PMs in laser room |