Session aimCherenkov detector - photomultiplier in laser room
Session day2009-03-19Operatorpduarte
Session IDISTTOK_2009319_1Coordinatorpduarte

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
217292009-03-19 17:25:52.029pduarte3.72.72640 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=60. IVERT=160A. PMs in laser room. batteries protection. fiber 4 disconnected. FD on tech 4.
217282009-03-19 17:13:58.645pduarte3.72.86740 turns primary. R = 0,4ohm. ELCO = 200V. P=1,0x10^(-4)mbar. Pre-Programmed H and V field. CHERENKOV=60. IVERT=160A. PMs in laser room. batteries protection. cherenkov 4 with FD.
217272009-03-19 17:08:03.222pduarte001ELCO circuit breaker failure
217262009-03-19 16:51:46.47pduarte3.72.82640 turns primary. R = 0,4ohm. ELCO = 200V. P=1,0x10^(-4)mbar. Pre-Programmed H and V field. CHERENKOV=60. IVERT=160A. PMs in laser room. batteries protection. FD on tech 4 without fiberoptic
217252009-03-19 16:44:27.031pduarte42.72640 turns primary. R = 0,4ohm. ELCO = 200V. P=1,0x10^(-4)mbar. Pre-Programmed H and V field. CHERENKOV=65. IVERT=160A. PMs in laser room. batteries protection
217242009-03-19 16:38:11.587pduarte42.62640 turns primary. R = 0,4ohm. ELCO = 200V. P=1,0x10^(-4)mbar. Pre-Programmed H and V field. CHERENKOV=70. IVERT=160A. PMs in laser room. batteries protection
217232009-03-19 16:28:02.267pduarte433540 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=90. IVERT=160A. PMs in laser room. fiber1 disconnected in detector. batteries protection
217222009-03-19 16:19:54.14pduarte433540 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=90. IVERT=160A. PMs in laser room. batteries protection
217212009-03-19 16:13:05.272pduarte3.92.92640 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=85. IVERT=160A. PMs in laser room. batteries protection
217202009-03-19 16:06:52.817pduarte3.41.82640 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=55. IVERT=160A. PMs in laser room. batteries protection
217192009-03-19 15:59:08.27pduarte3.41.92640 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=55. IVERT=160A. PMs in laser room. batteries protection
217182009-03-19 15:51:09.268pduarte3.42.22640 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=60. IVERT=160A. PMs in laser room. batteries protection
217172009-03-19 15:45:34.368pduarte001ELCO circuit breaker failure. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=60. IVERT=160A. PMs in laser room. batteries protection
217162009-03-19 15:38:40.448pduarte3.522640 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=60. IVERT=160A. PMs in laser room. batteries protection
217152009-03-19 15:31:29.216pduarte3.825040 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=65. IVERT=160A. PMs in laser room. batteries protection
217142009-03-19 15:24:52.36pduarte3.922640 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=65. IVERT=160A. PMs in laser room. batteries protection
217132009-03-19 15:18:24.734pduarte42.75040 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=70. IVERT=160A. PMs in laser room. batteries protection
217122009-03-19 15:10:49.479pduarte001ELCO circuit breaker failure. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=70. IVERT=160A. PMs in laser room. batteries protection
217112009-03-19 15:02:46.881pduarte42.55040 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=70. IVERT=160A. PMs in laser room. batteries protection
217102009-03-19 14:57:08.877pduarte435040 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=75. IVERT=160A. PMs in laser room. batteries protection
217092009-03-19 14:51:17.722pduarte434540 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=75. IVERT=160A. PMs in laser room. batteries protection
217082009-03-19 14:45:23.50pduarte433640 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=80. IVERT=160A. PMs in laser room. batteries protection
217072009-03-19 14:39:15.912pduarte433640 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=80. IVERT=160A. PMs in laser room. batteries protection
217062009-03-19 14:33:48.169pduarte433640 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=85. IVERT=160A. PMs in laser room. batteries protection
217052009-03-19 14:26:31.687pduarte-3.51.510PRECO Failure. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=85. IVERT=160A. PMs in laser room. batteries protection
217042009-03-19 14:13:03.526pduarte433640 turns primary. R = 0,4ohm. ELCO = 200V. P=8,0x10^(-5)mbar. Pre-Programmed H and V field. IVERT=160A.
217032009-03-19 12:57:18.042pduarte435040 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=100. IVERT=160A. PMs in laser room. fiber 1 off in the detector. batteries protection
217022009-03-19 12:50:20.559pduarte42.85040 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=70. IVERT=160A. PMs in laser room. fiber 1 off in the detector. batteries protection
217012009-03-19 12:44:53.853pduarte001ELCO circuit breaker failure
217002009-03-19 12:38:58.207pduarte435040 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=85. IVERT=160A. PMs in laser room. fiber 1 off in the detector. batteries protection
216992009-03-19 12:33:09.713pduarte435040 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=90. IVERT=160A. PMs in laser room. fiber 1 off in the detector. batteries protection
216982009-03-19 12:25:24.726pduarte435040 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=90. IVERT=160A. PMs in laser room. fiber 1 off in the detector. batteries protection
216972009-03-19 12:11:49.876pduarte3.92.55040 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=60. IVERT=160A. PMs in laser room. fiber 1 disconnected in the detector
216962009-03-19 12:00:35.25pduarte3.82.65040 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=60. IVERT=160A. PMs in laser room. fiber 1 disconnected in the detector
216952009-03-19 11:54:22.112pduarte435040 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=70. IVERT=160A. PMs in laser room. fiber 1 disconnected in the detector
216942009-03-19 11:39:38.108pduarte435040 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=80. IVERT=160A. PMs in laser room. fiber 1 disconnected in the PM
216932009-03-19 11:31:44.27pduarte435040 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=80. IVERT=160A. PMs in laser room. fiber 1 OFF
216922009-03-19 11:25:40.323pduarte001ELCO circuit breaker failure. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=80. IVERT=160A. PMs in laser room. fiber 1 OFF
216912009-03-19 11:17:06.06pduarte435040 turns primary. R = 0,4ohm. ELCO = 200V. P=6,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=80. IVERT=160A. PMs in laser room
216902009-03-19 11:09:28.907pduarte435040 turns primary. R = 0,4ohm. ELCO = 200V. P=8,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=325. IVERT=160A. PMs in laser room
216892009-03-19 11:03:56.273pduarte3.52.55040 turns primary. R = 0,4ohm. ELCO = 200V. P=8,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=325. IVERT=120A. PMs in laser room
216882009-03-19 10:57:39.417pduarte22.65040 turns primary. R = 0,4ohm. ELCO = 200V. P=1,0x10^(-4)mbar. Pre-Programmed H and V field. CHERENKOV=325. IVERT=80A. PMs in laser room