Session aimCherenkov detector - photomultiplier in laser room
Session day2009-03-20Operatorpduarte
Session IDISTTOK_2009320_1Coordinatorpduarte

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
217702009-03-20 17:25:29.086pduarte3.62.52640 turns primary. R = 0,4ohm. ELCO = 200V. P=5,0x10^(-5)mbar. Pre-Programmed H and V field. IVERT=160A. CHERENKOV=65. PMs in laser room. batteries protection. x-ray detector on cherenkov_4
217692009-03-20 17:19:13.817pduarte312640 turns primary. R = 0,4ohm. ELCO = 200V. P=5,0x10^(-5)mbar. Pre-Programmed H and V field. IVERT=120A. CHERENKOV=65. PMs in laser room. batteries protection. x-ray detector on cherenkov_4
217682009-03-20 17:07:55.024pduarte3.42.35040 turns primary. R = 0,4ohm. ELCO = 200V. P=5,0x10^(-5)mbar. Pre-Programmed H and V field. IVERT=120A. CHERENKOV=325. GATE-VALVE closed. batteries protection. x-ray detector on cherenkov_4
217672009-03-20 16:56:15.203pduarte3.42.32640 turns primary. R = 0,4ohm. ELCO = 200V. P=5,0x10^(-5)mbar. Pre-Programmed H and V field. IVERT=120A. CHERENKOV=100. PMs in laser room. batteries protection. x-ray detector on cherenkov_4
217662009-03-20 16:44:29.316pduarte3.52.22640 turns primary. R = 0,4ohm. ELCO = 200V. P=5,0x10^(-5)mbar. Pre-Programmed H and V field. IVERT=120A. CHERENKOV=90. PMs in laser room. batteries protection.
217652009-03-20 16:39:02.486pduarte3.52.32640 turns primary. R = 0,4ohm. ELCO = 200V. P=5,0x10^(-5)mbar. Pre-Programmed H and V field. IVERT=120A. CHERENKOV=85. PMs in laser room. batteries protection.
217642009-03-20 16:33:39.20pduarte3.52.44540 turns primary. R = 0,4ohm. ELCO = 200V. P=5,0x10^(-5)mbar. Pre-Programmed H and V field. IVERT=120A. CHERENKOV=85. PMs in laser room. batteries protection.
217632009-03-20 16:21:20.25pduarte3.62.35040 turns primary. R = 0,4ohm. ELCO = 200V. P=5,0x10^(-5)mbar. Pre-Programmed H and V field. IVERT=120A. CHERENKOV=80. PMs in laser room. batteries protection.
217622009-03-20 16:14:38.544pduarte3.62.45040 turns primary. R = 0,4ohm. ELCO = 200V. P=5,0x10^(-5)mbar. Pre-Programmed H and V field. IVERT=120A. CHERENKOV=80. PMs in laser room. batteries protection.
217612009-03-20 16:00:06.415pduarte3.62.42640 turns primary. R = 0,4ohm. ELCO = 200V. P=5,0x10^(-5)mbar. Pre-Programmed H and V field. IVERT=120A. CHERENKOV=75. PMs in laser room. batteries protection.
217602009-03-20 15:53:52.43pduarte3.42.55040 turns primary. R = 0,4ohm. ELCO = 200V. P=5,0x10^(-5)mbar. Pre-Programmed H and V field. IVERT=120A. CHERENKOV=75. PMs in laser room. batteries protection.
217592009-03-20 15:47:39.066pduarte3.21.52640 turns primary. R = 0,4ohm. ELCO = 200V. P=5,0x10^(-5)mbar. Pre-Programmed H and V field. IVERT=120A. CHERENKOV=70. PMs in laser room. batteries protection.
217582009-03-20 15:41:47.785pduarte3.21.62640 turns primary. R = 0,4ohm. ELCO = 200V. P=5,0x10^(-5)mbar. Pre-Programmed H and V field. IVERT=120A. CHERENKOV=70. PMs in laser room. batteries protection.
217572009-03-20 15:36:24.986pduarte3.11.22640 turns primary. R = 0,4ohm. ELCO = 200V. P=5,0x10^(-5)mbar. Pre-Programmed H and V field. IVERT=120A. CHERENKOV=65. PMs in laser room. batteries protection.
217562009-03-20 15:30:55.623pduarte3.11.22640 turns primary. R = 0,4ohm. ELCO = 200V. P=5,0x10^(-5)mbar. Pre-Programmed H and V field. IVERT=120A. CHERENKOV=65. PMs in laser room. batteries protection.
217552009-03-20 15:16:55.154pduarte3.11.32640 turns primary. R = 0,4ohm. ELCO = 200V. P=5,0x10^(-5)mbar. Pre-Programmed H and V field. IVERT=120A. CHERENKOV=60. PMs in laser room. batteries protection.
217542009-03-20 15:09:50.467pduarte3.31.32640 turns primary. R = 0,4ohm. ELCO = 200V. P=5,0x10^(-5)mbar. Pre-Programmed H and V field. IVERT=120A. CHERENKOV=60. PMs in laser room. batteries protection.
217532009-03-20 15:02:51.044pduarte3.11.32640 turns primary. R = 0,4ohm. ELCO = 200V. P=5,0x10^(-5)mbar. Pre-Programmed H and V field. IVERT=120A. CHERENKOV=55. PMs in laser room. batteries protection.
217522009-03-20 14:57:29.30pduarte3.11.52640 turns primary. R = 0,4ohm. ELCO = 200V. P=5,0x10^(-5)mbar. Pre-Programmed H and V field. IVERT=120A. CHERENKOV=55. PMs in laser room. batteries protection.
217512009-03-20 14:51:09.949pduarte3.52.85040 turns primary. R = 0,4ohm. ELCO = 200V. P=8,0x10^(-5)mbar. Pre-Programmed H and V field. IVERT=120A. CHERENKOV=105. PMs in laser room. batteries protection.
217502009-03-20 14:45:07.989pduarte00140 turns primary. R = 0,4ohm. ELCO = 200V. P=8,0x10^(-5)mbar. Pre-Programmed H and V field. IVERT=OFF. CHERENKOV=105. PMs in laser room. batteries protection. PMs off
217492009-03-20 14:34:28.357pduarte00140 turns primary. R = 0,4ohm. ELCO = 200V. P=8,0x10^(-5)mbar. Pre-Programmed H and V field. IVERT=OFF. CHERENKOV=55. PMs in laser room. batteries protection. PMs off
217482009-03-20 12:51:51.081pduarte3.82.42640 turns primary. R = 0,4ohm. ELCO = 200V. P=1,0x10^(-4)mbar. Pre-Programmed H and V field. IVERT=160A. CHERENKOV=55. PMs in laser room. batteries protection.
217472009-03-20 12:46:22.058pduarte001ELCO circuit breaker failure. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=1,0x10^(-4)mbar. Pre-Programmed H and V field. IVERT=160A. CHERENKOV=55. PMs in laser room. batteries protection.
217462009-03-20 12:40:54.60pduarte3.82.12640 turns primary. R = 0,4ohm. ELCO = 200V. P=1,0x10^(-4)mbar. Pre-Programmed H and V field. IVERT=160A. CHERENKOV=55. PMs in laser room. batteries protection.
217452009-03-20 12:35:01.374pduarte42.35040 turns primary. R = 0,4ohm. ELCO = 200V. P=1,0x10^(-4)mbar. Pre-Programmed H and V field. IVERT=160A. CHERENKOV=60. PMs in laser room. batteries protection.
217442009-03-20 12:28:19.816pduarte42.45040 turns primary. R = 0,4ohm. ELCO = 200V. P=1,0x10^(-4)mbar. Pre-Programmed H and V field. IVERT=160A. CHERENKOV=60. PMs in laser room. batteries protection.
217432009-03-20 12:22:32.048pduarte4.32.62640 turns primary. R = 0,4ohm. ELCO = 200V. P=1,0x10^(-4)mbar. Pre-Programmed H and V field. IVERT=160A. CHERENKOV=65. PMs in laser room. batteries protection.
217422009-03-20 12:17:11.611pduarte4.32.62640 turns primary. R = 0,4ohm. ELCO = 200V. P=1,0x10^(-4)mbar. Pre-Programmed H and V field. IVERT=160A. CHERENKOV=65. PMs in laser room. batteries protection.
217412009-03-20 12:11:36.54pduarte4.32.82640 turns primary. R = 0,4ohm. ELCO = 200V. P=1,0x10^(-4)mbar. Pre-Programmed H and V field. IVERT=160A. CHERENKOV=70. PMs in laser room. batteries protection.
217402009-03-20 12:04:41.242pduarte4.32.92640 turns primary. R = 0,4ohm. ELCO = 200V. P=1,0x10^(-4)mbar. Pre-Programmed H and V field. IVERT=160A. CHERENKOV=70. PMs in laser room. batteries protection.
217392009-03-20 11:58:47.631pduarte4.532640 turns primary. R = 0,4ohm. ELCO = 200V. P=1,0x10^(-4)mbar. Pre-Programmed H and V field. IVERT=160A. CHERENKOV=75. PMs in laser room. batteries protection.
217382009-03-20 11:53:23.637pduarte4.532640 turns primary. R = 0,4ohm. ELCO = 200V. P=1,0x10^(-4)mbar. Pre-Programmed H and V field. IVERT=160A. CHERENKOV=75. PMs in laser room. batteries protection.
217372009-03-20 11:47:59.924pduarte432640 turns primary. R = 0,4ohm. ELCO = 200V. P=1,0x10^(-4)mbar. Pre-Programmed H and V field. IVERT=160A. CHERENKOV=80. PMs in laser room. batteries protection.
217362009-03-20 11:41:01.155pduarte435040 turns primary. R = 0,4ohm. ELCO = 200V. P=1,0x10^(-4)mbar. Pre-Programmed H and V field. IVERT=160A. CHERENKOV=80. PMs in laser room. batteries protection.
217352009-03-20 11:33:49.436pduarte432640 turns primary. R = 0,4ohm. ELCO = 200V. P=1,0x10^(-4)mbar. Pre-Programmed H and V field. IVERT=160A. CHERENKOV=85. PMs in laser room. batteries protection.
217342009-03-20 11:27:37.435pduarte435040 turns primary. R = 0,4ohm. ELCO = 200V. P=1,0x10^(-4)mbar. Pre-Programmed H and V field. IVERT=160A. CHERENKOV=85. PMs in laser room. batteries protection.
217332009-03-20 11:21:26.664pduarte435040 turns primary. R = 0,4ohm. ELCO = 200V. P=1,0x10^(-4)mbar. Pre-Programmed H and V field. IVERT=160A. CHERENKOV=90. PMs in laser room. batteries protection.
217322009-03-20 11:14:35.377pduarte4.335040 turns primary. R = 0,4ohm. ELCO = 200V. P=1,0x10^(-4)mbar. Pre-Programmed H and V field. IVERT=160A. CHERENKOV=90. PMs in laser room. batteries protection.
217312009-03-20 11:05:51.616pduarte326940 turns primary. R = 0,4ohm. ELCO = 200V. P=1,0x10^(-4)mbar. Pre-Programmed H and V field. IVERT=100A.
217302009-03-20 10:58:30.548pduarte32.53540 turns primary. R = 0,4ohm. ELCO = 200V. P=1,0x10^(-4)mbar. Pre-Programmed H and V field. IVERT=160A.