Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
214132009-03-03 15:37:42.15pduarte1.82.61940 turns primary. R = 0,4ohm. ELCO = 240V. P=4,2x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=65.
214122009-03-03 15:30:42.235pduarte1.82.71940 turns primary. R = 0,4ohm. ELCO = 240V. P=4,2x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=65.
214112009-03-03 15:20:41.771pduarte1.62.61940 turns primary. R = 0,4ohm. ELCO = 240V. P=5,5x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=65.
214102009-03-03 15:08:39.08pduarte00040 turns primary. R = 0,4ohm. ELCO = 240V. P=3,6x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=65.
214092009-03-03 15:01:21.985pduarte1.52.61940 turns primary. R = 0,4ohm. ELCO = 240V. P=8,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=65.
214082009-03-03 14:52:36.206pduarte1.62.51940 turns primary. R = 0,4ohm. ELCO = 240V. P=8,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=65. Change PM 1 and 4
214072009-03-03 14:45:48.66pduarte1.52.61940 turns primary. R = 0,4ohm. ELCO = 240V. P=1,0x10^(-4)mbar. Pre-Programmed H and V field. CHERENKOV=65. Change PM 1 and 4
214062009-03-03 14:39:29.984pduarte1.42.61940 turns primary. R = 0,4ohm. ELCO = 240V. P=1,0x10^(-4)mbar. Pre-Programmed H and V field. CHERENKOV=65.
214052009-03-03 14:31:59.173pduarte1.12.41540 turns primary. R = 0,4ohm. ELCO = 240V. P=1,0x10^(-4)mbar. Pre-Programmed H and V field. CHERENKOV=65.
214042009-03-03 12:53:29.03pduarte2.92.91940 turns primary. R = 0,4ohm. ELCO = 240V. P=3,6x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=65.
214032009-03-03 12:47:25.743pduarte32.91940 turns primary. R = 0,4ohm. ELCO = 240V. P=4,2x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=65.
214022009-03-03 12:39:50.969pduarte32.91940 turns primary. R = 0,4ohm. ELCO = 240V. P=4,2x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=65.
214012009-03-03 12:34:18.844pduarte32.91940 turns primary. R = 0,4ohm. ELCO = 240V. P=5,5x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=65.
214002009-03-03 12:26:41.265pduarte2.72.71940 turns primary. R = 0,4ohm. ELCO = 240V. P=5,5x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=65.
213992009-03-03 12:19:15.308pduarte2.42.64140 turns primary. R = 0,4ohm. ELCO = 220V. P=5,5x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=65.
213982009-03-03 12:12:32.712pduarte2.22.54240 turns primary. R = 0,4ohm. ELCO = 220V. P=5,5x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=65.
213972009-03-03 12:05:00.763pduarte1.92.54140 turns primary. R = 0,4ohm. ELCO = 220V. P=8,0x10^(-5)mbar. Pre-Programmed H and V field. CHERENKOV=65.
213962009-03-03 11:56:11.05pduarte1.82.57040 turns primary. R = 0,4ohm. ELCO = 220V. P=1,0x10^(-4)mbar. Pre-Programmed H and V field.
213952009-03-03 11:48:33.906pduarte1.82.79340 turns primary. R = 0,4ohm. ELCO = 220V. P=1,1x10^(-4)mbar. Pre-Programmed H and V field.
213942009-03-03 11:41:49.637pduarte1.62.79340 turns primary. R = 0,4ohm. ELCO = 220V. P=1,1x10^(-4)mbar. Pre-Programmed H and V field.
213932009-03-03 11:33:25.343pduarte1.52.570PRECO failure. 40 turns primary. R = 0,4ohm. ELCO = 220V. P=1,1x10^(-4)mbar. Pre-Programmed H and V field.
213922009-03-03 11:24:47.445pduarte12.69340 turns primary. R = 0,4ohm. ELCO = 220V. P=1,0x10^(-4)mbar. Pre-Programmed H and V field.