Shot
|
Time
|
Operator
|
Iplasma(kA)
|
n(1018m-3)
|
Duration (ms)
|
Pre/post shot comments
|
| 21514 | 2009-03-09 17:27:50.712 | pduarte | 4 | 2.5 | 41 | 40 turns primary. R = 0,4ohm. ELCO = 220V. P=5,0x10^(-5)mbar. Pre-Programmed H and V field. RAKE= 70. RAKE on temperature. CHERENKOV=75. IVERT=80A on first and 160A on third |
| 21513 | 2009-03-09 17:20:33.216 | pduarte | 4.4 | 3.5 | 74 | 40 turns primary. R = 0,4ohm. ELCO = 220V. P=4,6x10^(-5)mbar. Pre-Programmed H and V field. RAKE= 70. RAKE on temperature. CHERENKOV=75. IVERT=160A |
| 21512 | 2009-03-09 17:14:56.718 | pduarte | 4 | 3.5 | 74 | 40 turns primary. R = 0,4ohm. ELCO = 220V. P=8,0x10^(-5)mbar. Pre-Programmed H and V field. RAKE= 70. RAKE on temperature. CHERENKOV=75. IVERT=160A |
| 21511 | 2009-03-09 17:07:18.884 | pduarte | 4 | 3.5 | 74 | 40 turns primary. R = 0,4ohm. ELCO = 220V. P=5,0x10^(-5)mbar. Pre-Programmed H and V field. RAKE= 70. RAKE on temperature. CHERENKOV=75. IVERT=160A |
| 21510 | 2009-03-09 16:58:05.229 | pduarte | 4.4 | 4.5 | 19 | 40 turns primary. R = 0,4ohm. ELCO = 240V. P=5,0x10^(-5)mbar. Pre-Programmed H and V field. RAKE= 70. RAKE on temperature. CHERENKOV=75. IVERT=160A |
| 21509 | 2009-03-09 16:45:36.072 | pduarte | 4.1 | 3.9 | 19 | 40 turns primary. R = 0,4ohm. ELCO = 240V. P=5,0x10^(-5)mbar. Pre-Programmed H and V field. RAKE= 70. RAKE on temperature. CHERENKOV=70. IVERT=100A and 140A |
| 21508 | 2009-03-09 16:34:30.402 | pduarte | 4.2 | 4 | 19 | 40 turns primary. R = 0,4ohm. ELCO = 240V. P=5,0x10^(-5)mbar. Pre-Programmed H and V field. RAKE= 70. RAKE on temperature. CHERENKOV=70. IVERT=120A and 160A |
| 21507 | 2009-03-09 16:27:51.421 | pduarte | 4.5 | 4.5 | 19 | 40 turns primary. R = 0,4ohm. ELCO = 240V. P=5,0x10^(-5)mbar. Pre-Programmed H and V field. RAKE= 70. RAKE on temperature. CHERENKOV=70. IVERT=160A |
| 21506 | 2009-03-09 16:21:37.119 | pduarte | 4.3 | 4.2 | 19 | 40 turns primary. R = 0,4ohm. ELCO = 240V. P=5,0x10^(-5)mbar. Pre-Programmed H and V field. RAKE= 70. RAKE on temperature. CHERENKOV=70. IVERT=160A |
| 21505 | 2009-03-09 16:14:46.097 | pduarte | 3.8 | 3.4 | 19 | 40 turns primary. R = 0,4ohm. ELCO = 240V. P=5,0x10^(-5)mbar. Pre-Programmed H and V field. RAKE= 70. RAKE on temperature. CHERENKOV=60. IVERT=100A and 140A |
| 21504 | 2009-03-09 16:03:02.113 | pduarte | 3.5 | 3 | 19 | 40 turns primary. R = 0,4ohm. ELCO = 240V. P=5,0x10^(-5)mbar. Pre-Programmed H and V field. RAKE= 70. RAKE on temperature. CHERENKOV=60. IVERT=100A. |
| 21503 | 2009-03-09 15:50:31.026 | pduarte | 3.2 | 3 | 10 | 40 turns primary. R = 0,4ohm. ELCO = 240V. P=5,0x10^(-5)mbar. Pre-Programmed H and V field. RAKE= 65. RAKE on temperature. CHERENKOV=60. IVERT=0A. |
| 21502 | 2009-03-09 15:39:02.268 | pduarte | 4.1 | 4.7 | 19 | 40 turns primary. R = 0,4ohm. ELCO = 240V. P=5,0x10^(-5)mbar. Pre-Programmed H and V field. RAKE= 65. RAKE on temperature. CHERENKOV=60. IVERT=160A. |
| 21501 | 2009-03-09 15:32:21.58 | pduarte | 4 | 4.5 | 19 | 40 turns primary. R = 0,4ohm. ELCO = 240V. P=8,0x10^(-5)mbar. Pre-Programmed H and V field. RAKE= 65. RAKE on temperature. CHERENKOV=60. IVERT=160A. |
| 21500 | 2009-03-09 15:24:39.683 | pduarte | 4 | 4.5 | 19 | 40 turns primary. R = 0,4ohm. ELCO = 240V. P=5,0x10^(-5)mbar. Pre-Programmed H and V field. RAKE= 65. RAKE on temperature. CHERENKOV=65. IVERT=160A. |
| 21499 | 2009-03-09 15:19:19.192 | pduarte | 4 | 4.5 | 19 | 40 turns primary. R = 0,4ohm. ELCO = 240V. P=8,0x10^(-5)mbar. Pre-Programmed H and V field. RAKE= 65. RAKE on temperature. CHERENKOV=65. IVERT=160A. |
| 21498 | 2009-03-09 15:12:35.914 | pduarte | 4 | 4.5 | 19 | 40 turns primary. R = 0,4ohm. ELCO = 240V. P=5,0x10^(-5)mbar. Pre-Programmed H and V field. RAKE= 65. RAKE on temperature. CHERENKOV=70. IVERT=160A. |
| 21497 | 2009-03-09 15:00:47.774 | pduarte | 0 | 0 | 19 | 40 turns primary. R = 0,4ohm. ELCO = 240V. P=8,0x10^(-5)mbar. Pre-Programmed H and V field. RAKE= 65. RAKE on temperature. CHERENKOV=70. IVERT=160A. Central node acquisition failure |
| 21496 | 2009-03-09 14:51:56.96 | pduarte | 3.8 | 4 | 19 | 40 turns primary. R = 0,4ohm. ELCO = 240V. P=8,0x10^(-5)mbar. Pre-Programmed H and V field. RAKE= 65. RAKE on temperature. CHERENKOV=70. IVERT=120A. |
| 21495 | 2009-03-09 14:43:28.169 | pduarte | 3.1 | 3.3 | 19 | 40 turns primary. R = 0,4ohm. ELCO = 240V. P=1,0x10^(-4)mbar. Pre-Programmed H and V field. RAKE= 65. RAKE on temperature. CHERENKOV=70. IVERT=80A. cherenkov acquisition error |
| 21494 | 2009-03-09 14:35:00.719 | pduarte | 2.3 | 3 | 19 | 40 turns primary. R = 0,4ohm. ELCO = 240V. P=1,0x10^(-4)mbar. Pre-Programmed H and V field. RAKE= 65. CHERENKOV=out |
| 21493 | 2009-03-09 14:29:21.974 | pduarte | 0 | 0 | 1 | ELCO circuit breaker failure. 40 turns primary. R = 0,4ohm. ELCO = 240V. P=1,0x10^(-4)mbar. Pre-Programmed H and V field. RAKE= 65. CHERENKOV=out |
| 21492 | 2009-03-09 14:23:16.632 | pduarte | 0 | 0 | 0 | PRECO failure. 40 turns primary. R = 0,4ohm. ELCO = 240V. P=1,0x10^(-4)mbar. Pre-Programmed H and V field. RAKE= 65. CHERENKOV=out |
| 21491 | 2009-03-09 14:13:24.389 | pduarte | 0 | 0 | 0 | PRECO failure. 40 turns primary. R = 0,4ohm. ELCO = 240V. P=1,0x10^(-4)mbar. Pre-Programmed H and V field. RAKE= 65. CHERENKOV=out |
| 21490 | 2009-03-09 14:03:27.486 | pduarte | 1.8 | 3.1 | 19 | 40 turns primary. R = 0,4ohm. ELCO = 240V. P=1,0x10^(-4)mbar. Pre-Programmed H and V field. |