Shot
|
Time
|
Operator
|
Iplasma(kA)
|
n(1018m-3)
|
Duration (ms)
|
Pre/post shot comments
|
| 22364 | 2009-04-27 16:09:22.762 | pduarte | 3 | 3.2 | 25 | 40 turns primary. R = 0,4ohm. ELCO = 220V. P=1,4x10^(-4)mbar. Pre-Programmed H and V field. |
| 22363 | 2009-04-27 16:03:53.521 | pduarte | 3 | 3.2 | 25 | 40 turns primary. R = 0,4ohm. ELCO = 220V. P=1,4x10^(-4)mbar. Pre-Programmed H and V field. |
| 22362 | 2009-04-27 15:53:44.186 | pduarte | 3.1 | 3.2 | 25 | 40 turns primary. R = 0,4ohm. ELCO = 220V. P=1,4x10^(-4)mbar. Pre-Programmed H and V field. |
| 22361 | 2009-04-27 15:47:34.066 | pduarte | 3 | 3.2 | 25 | 40 turns primary. R = 0,4ohm. ELCO = 220V. P=1,4x10^(-4)mbar. Pre-Programmed H and V field. |
| 22360 | 2009-04-27 15:40:23.625 | pduarte | 3 | 3.2 | 25 | 40 turns primary. R = 0,4ohm. ELCO = 220V. P=1,4x10^(-4)mbar. Pre-Programmed H and V field. |
| 22359 | 2009-04-27 15:33:39.024 | pduarte | 3 | 3.2 | 25 | 40 turns primary. R = 0,4ohm. ELCO = 220V. P=1,4x10^(-4)mbar. Pre-Programmed H and V field. |
| 22358 | 2009-04-27 15:26:58.219 | pduarte | 3 | 3.1 | 25 | 40 turns primary. R = 0,4ohm. ELCO = 220V. P=1,4x10^(-4)mbar. Pre-Programmed H and V field. |
| 22357 | 2009-04-27 15:20:44.79 | pduarte | 3 | 3.2 | 25 | 40 turns primary. R = 0,4ohm. ELCO = 220V. P=1,4x10^(-4)mbar. Pre-Programmed H and V field. |
| 22356 | 2009-04-27 15:14:22.799 | pduarte | 3.1 | 3.2 | 25 | 40 turns primary. R = 0,4ohm. ELCO = 220V. P=1,4x10^(-4)mbar. Pre-Programmed H and V field. |
| 22355 | 2009-04-27 15:06:55.041 | pduarte | 3.1 | 3.2 | 25 | 40 turns primary. R = 0,4ohm. ELCO = 220V. P=1,4x10^(-4)mbar. Pre-Programmed H and V field. |
| 22354 | 2009-04-27 15:01:21.715 | pduarte | 3 | 3.2 | 25 | 40 turns primary. R = 0,4ohm. ELCO = 220V. P=1,4x10^(-4)mbar. Pre-Programmed H and V field. |
| 22353 | 2009-04-27 14:54:32.728 | pduarte | 3 | 3.2 | 25 | 40 turns primary. R = 0,4ohm. ELCO = 220V. P=1,4x10^(-4)mbar. Pre-Programmed H and V field. |
| 22352 | 2009-04-27 14:47:47.976 | pduarte | 2.9 | 3.3 | 25 | 40 turns primary. R = 0,4ohm. ELCO = 220V. P=1,4x10^(-4)mbar. Pre-Programmed H and V field. |
| 22351 | 2009-04-27 14:41:09.598 | pduarte | 3 | 3.2 | 25 | 40 turns primary. R = 0,4ohm. ELCO = 220V. P=1,4x10^(-4)mbar. Pre-Programmed H and V field. |
| 22350 | 2009-04-27 14:35:00.331 | pduarte | 3.1 | 3.1 | 25 | 40 turns primary. R = 0,4ohm. ELCO = 220V. P=1,3x10^(-4)mbar. Pre-Programmed H and V field. |
| 22349 | 2009-04-27 14:28:48.812 | pduarte | 3 | 3 | 25 | 40 turns primary. R = 0,4ohm. ELCO = 220V. P=1,3x10^(-4)mbar. Pre-Programmed H and V field. |
| 22348 | 2009-04-27 14:23:14.169 | pduarte | 2.7 | 3 | 25 | 40 turns primary. R = 0,4ohm. ELCO = 220V. P=1,3x10^(-4)mbar. Pre-Programmed H and V field. |
| 22347 | 2009-04-27 14:17:37.727 | pduarte | 2.5 | 2.8 | 25 | 40 turns primary. R = 0,4ohm. ELCO = 220V. P=1,3x10^(-4)mbar. Pre-Programmed H and V field. |
| 22346 | 2009-04-27 14:12:11.009 | pduarte | 2.4 | 2.8 | 25 | 40 turns primary. R = 0,4ohm. ELCO = 220V. P=1,3x10^(-4)mbar. Pre-Programmed H and V field. |
| 22345 | 2009-04-27 14:06:44.666 | pduarte | 2 | 2.8 | 25 | 40 turns primary. R = 0,4ohm. ELCO = 220V. P=1,3x10^(-4)mbar. Pre-Programmed H and V field. |
| 22344 | 2009-04-27 13:57:56.162 | pduarte | 1.7 | 2.7 | 25 | 40 turns primary. R = 0,4ohm. ELCO = 220V. P=1,3x10^(-4)mbar. Pre-Programmed H and V field. |
| 22343 | 2009-04-27 13:52:19.392 | pduarte | 1.9 | 2.7 | 25 | 40 turns primary. R = 0,4ohm. ELCO = 220V. P=1,2x10^(-4)mbar. Pre-Programmed H and V field. |
| 22342 | 2009-04-27 13:45:09.32 | pduarte | 1.8 | 2.5 | 25 | 40 turns primary. R = 0,4ohm. ELCO = 220V. P=1,2x10^(-4)mbar. Pre-Programmed H and V field. |
| 22341 | 2009-04-27 13:39:04.011 | pduarte | 1.6 | 2.5 | 25 | 40 turns primary. R = 0,4ohm. ELCO = 220V. P=1,2x10^(-4)mbar. Pre-Programmed H and V field. |
| 22340 | 2009-04-27 13:33:23.718 | pduarte | 1.4 | 2.2 | 25 | 40 turns primary. R = 0,4ohm. ELCO = 220V. P=1,2x10^(-4)mbar. Pre-Programmed H and V field. |
| 22339 | 2009-04-27 13:26:44.518 | pduarte | 1.2 | 2.5 | 25 | 40 turns primary. R = 0,4ohm. ELCO = 220V. P=1,2x10^(-4)mbar. Pre-Programmed H and V field. |
| 22338 | 2009-04-27 13:18:48.472 | pduarte | 0.8 | 2.3 | 20 | 40 turns primary. R = 0,4ohm. ELCO = 200V. P=1,4x10^(-4)mbar. Pre-Programmed H and V field. |
| 22337 | 2009-04-27 13:11:41.227 | pduarte | 1 | 1.5 | 32 | 40 turns primary. R = 0,4ohm. ELCO = 200V. P=1,2x10^(-4)mbar. Pre-Programmed H and V field. |
| 22336 | 2009-04-27 13:06:15.732 | pduarte | 0 | 0 | 1 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,3x10^(-4)mbar. Pre-Programmed H and V field. |