Shot
|
Time
|
Operator
|
Iplasma(kA)
|
n(1018m-3)
|
Duration (ms)
|
Pre/post shot comments
|
| 22955 | 2009-06-23 16:06:33.947 | pduarte | 3.3 | 2.6 | 31 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field. |
| 22954 | 2009-06-23 16:01:05.811 | pduarte | 3.2 | 2.5 | 31 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field. |
| 22953 | 2009-06-23 15:55:09.637 | pduarte | 0 | 0 | 2 | ELCO circuit breaker failure |
| 22952 | 2009-06-23 15:49:17.809 | pduarte | 3.4 | 2.6 | 31 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field. |
| 22951 | 2009-06-23 15:43:12.12 | pduarte | 3.5 | 2.6 | 31 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field. |
| 22950 | 2009-06-23 15:36:52.639 | pduarte | 3.4 | 2.7 | 31 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field. |
| 22948 | 2009-06-23 15:25:45.967 | pduarte | 3.5 | 2.7 | 31 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field. |
| 22947 | 2009-06-23 15:20:11.19 | pduarte | 3.5 | 2.7 | 31 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field. |
| 22946 | 2009-06-23 15:13:42.975 | pduarte | 3.4 | 2.8 | 31 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field. |
| 22945 | 2009-06-23 15:08:12.681 | pduarte | 3.4 | 2.7 | 31 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field. |
| 22944 | 2009-06-23 15:02:35.556 | pduarte | 3.4 | 2.8 | 31 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field. |
| 22943 | 2009-06-23 14:56:38.424 | pduarte | 3.5 | 2.7 | 31 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field. |
| 22942 | 2009-06-23 14:51:01.252 | pduarte | 3.4 | 2.7 | 31 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field. |
| 22941 | 2009-06-23 14:45:11.917 | pduarte | 3.4 | 2.7 | 31 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field. |
| 22940 | 2009-06-23 14:39:32.896 | pduarte | 3.5 | 2.7 | 31 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field. |
| 22939 | 2009-06-23 14:33:55.744 | pduarte | 3.5 | 2.7 | 31 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field. |
| 22938 | 2009-06-23 14:28:05.835 | pduarte | 3.4 | 2.7 | 31 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field. |
| 22937 | 2009-06-23 14:21:40.77 | pduarte | 3.4 | 2.7 | 31 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field. |
| 22936 | 2009-06-23 14:15:58.668 | pduarte | 3.3 | 2.6 | 31 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field. |
| 22935 | 2009-06-23 14:10:30.118 | pduarte | 3.1 | 2.6 | 31 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field. |
| 22934 | 2009-06-23 14:04:50.554 | pduarte | 3.1 | 2.5 | 31 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field. |
| 22933 | 2009-06-23 13:59:23.83 | pduarte | 2.9 | 2.5 | 31 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field. |
| 22932 | 2009-06-23 13:53:53.009 | pduarte | 2.4 | 2.3 | 31 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field. |
| 22931 | 2009-06-23 13:48:13.801 | pduarte | 2.1 | 2.3 | 31 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,30x10^(-4)mbar. Pre-Programmed H and V field. |
| 22930 | 2009-06-23 13:42:23.49 | pduarte | 1.5 | 2.4 | 31 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,20x10^(-4)mbar. Pre-Programmed H and V field. |
| 22929 | 2009-06-23 13:36:27.725 | pduarte | 1.5 | 2.4 | 31 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,20x10^(-4)mbar. Pre-Programmed H and V field. |
| 22928 | 2009-06-23 13:30:25.217 | pduarte | 0 | 0 | 0 | PRECO failure |
| 22927 | 2009-06-23 13:12:50.025 | pduarte | 1.4 | 2.4 | 31 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,20x10^(-4)mbar. Pre-Programmed H and V field. |