Session aimRFA tests
Session day2009-06-26Operatorpduarte
Session IDISTTOK_2009626_1Coordinatorpduarte

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
230512009-06-26 12:07:19.886pduarte1.62.32740 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field.
230502009-06-26 12:01:52.683pduarte1.62.22740 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field.
230492009-06-26 11:56:32.916pduarte1.62.32740 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field.
230482009-06-26 11:51:08.041pduarte1.52.32740 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field.
230472009-06-26 11:45:35.283pduarte1.42.22740 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field.
230462009-06-26 11:38:17.571pduarte1.421440 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Plasma Position node failure
230452009-06-26 11:32:20.814pduarte1.52.32740 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field.
230442009-06-26 11:26:06.758pduarte1.62.22740 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field.
230432009-06-26 11:20:08.533pduarte1.52.22740 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field.
230422009-06-26 11:14:31.271pduarte1.62.32740 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field.
230412009-06-26 11:08:55.842pduarte1.72.22740 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field.
230402009-06-26 11:03:12.184pduarte1.82.22740 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field. AC
230392009-06-26 10:57:15.673pduarte1.62.35040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field. AC
230382009-06-26 10:51:06.403pduarte1.52.35040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field. AC
230372009-06-26 10:45:30.719pduarte1.52.35040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,30x10^(-4)mbar. Pre-Programmed H and V field. AC
230362009-06-26 10:39:47.995pduarte000PRECO failures
230352009-06-26 10:34:04.606pduarte1.52.34740 turns primary. R = 0,4ohm. ELCO = 190V. P=1,30x10^(-4)mbar. Pre-Programmed H and V field. AC
230342009-06-26 10:27:54.392pduarte1.42.35040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,30x10^(-4)mbar. Pre-Programmed H and V field. AC
230322009-06-26 10:15:49.67pduarte1.32.44740 turns primary. R = 0,4ohm. ELCO = 190V. P=1,30x10^(-4)mbar. Pre-Programmed H and V field. AC
230312009-06-26 10:09:31.719pduarte12.34740 turns primary. R = 0,4ohm. ELCO = 190V. P=1,30x10^(-4)mbar. Pre-Programmed H and V field. AC
230302009-06-26 10:04:01.389pduarte-12.51540 turns primary. R = 0,4ohm. ELCO = 190V. P=1,30x10^(-4)mbar. Pre-Programmed H and V field. AC
230292009-06-26 09:58:19.48pduarte-12.51540 turns primary. R = 0,4ohm. ELCO = 190V. P=1,30x10^(-4)mbar. Pre-Programmed H and V field. AC
230282009-06-26 09:52:42.272pduarte1.12.34740 turns primary. R = 0,4ohm. ELCO = 190V. P=1,30x10^(-4)mbar. Pre-Programmed H and V field. AC
230272009-06-26 09:47:13.793pduarte12.34540 turns primary. R = 0,4ohm. ELCO = 190V. P=1,20x10^(-4)mbar. Pre-Programmed H and V field. AC
230262009-06-26 09:41:24.99pduarte000PRECO failure
230252009-06-26 09:35:18.896pduarte1.32.24440 turns primary. R = 0,4ohm. ELCO = 190V. P=1,20x10^(-4)mbar. Pre-Programmed H and V field. AC
230242009-06-26 09:28:51.024pduarte1.12.24440 turns primary. R = 0,4ohm. ELCO = 190V. P=1,20x10^(-4)mbar. Pre-Programmed H and V field. AC
230232009-06-26 09:23:15.342pduarte12.24340 turns primary. R = 0,4ohm. ELCO = 190V. P=1,20x10^(-4)mbar. Pre-Programmed H and V field. AC
230222009-06-26 09:15:49.156pduarte0.92.24340 turns primary. R = 0,4ohm. ELCO = 190V. P=1,20x10^(-4)mbar. Pre-Programmed H and V field. AC
230212009-06-26 09:09:47.851pduarte0.724340 turns primary. R = 0,4ohm. ELCO = 190V. P=1,20x10^(-4)mbar. Pre-Programmed H and V field. AC