Shot
|
Time
|
Operator
|
Iplasma(kA)
|
n(1018m-3)
|
Duration (ms)
|
Pre/post shot comments
|
| 22914 | 2009-06-05 12:02:46.625 | pduarte | 3.1 | 2.3 | 31 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. ATCA acquisition tests. |
| 22913 | 2009-06-05 11:56:46.333 | pduarte | 3.1 | 2.3 | 31 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. ATCA acquisition tests. |
| 22912 | 2009-06-05 11:51:21.076 | pduarte | 3.1 | 2.3 | 31 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. ATCA acquisition tests. |
| 22911 | 2009-06-05 11:45:40.374 | pduarte | 3.1 | 2.2 | 31 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. ATCA acquisition tests. |
| 22910 | 2009-06-05 11:39:17.007 | pduarte | 3.1 | 2.2 | 31 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. ATCA acquisition tests. |
| 22909 | 2009-06-05 11:33:50.518 | pduarte | 3.1 | 2.3 | 31 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. ATCA acquisition tests. |
| 22908 | 2009-06-05 11:28:03.028 | pduarte | 0 | 0 | 1 | ELCO circuit breaker failure |
| 22907 | 2009-06-05 11:22:35.425 | pduarte | 3.1 | 2.3 | 31 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. ATCA acquisition tests. |
| 22906 | 2009-06-05 11:16:36.647 | pduarte | 3.1 | 2.3 | 31 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. ATCA acquisition tests. |
| 22905 | 2009-06-05 11:10:38.767 | pduarte | 3 | 2.3 | 31 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. ATCA acquisition tests. |
| 22904 | 2009-06-05 11:02:53.666 | pduarte | 0 | 0 | 1 | ELCO circuit breaker failure |
| 22903 | 2009-06-05 10:56:38.45 | pduarte | 3.2 | 2.2 | 31 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. ATCA acquisition tests. |
| 22902 | 2009-06-05 10:51:11.046 | pduarte | 3.1 | 2.2 | 31 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. ATCA acquisition tests. |
| 22901 | 2009-06-05 10:44:52.276 | pduarte | 3 | 2.2 | 31 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. ATCA acquisition tests. |
| 22900 | 2009-06-05 10:38:54.595 | pduarte | 0 | 0 | 1 | ELCO circuit breaker failure |
| 22899 | 2009-06-05 10:33:26.07 | pduarte | 3.1 | 2.2 | 31 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. ATCA acquisition tests. |
| 22898 | 2009-06-05 10:27:19.322 | pduarte | 3 | 2.2 | 31 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. ATCA acquisition tests. |
| 22897 | 2009-06-05 10:21:19.668 | pduarte | 2.9 | 2.1 | 31 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. ATCA acquisition tests. |
| 22896 | 2009-06-05 10:14:50.305 | pduarte | 3 | 2.1 | 31 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. ATCA acquisition tests. |
| 22895 | 2009-06-05 10:06:02.894 | pduarte | 2.8 | 2.1 | 31 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. ATCA acquisition tests. |
| 22894 | 2009-06-05 09:59:48.004 | pduarte | 2.6 | 2.3 | 31 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. ATCA acquisition tests. |
| 22893 | 2009-06-05 09:53:58.257 | pduarte | 2.5 | 2.3 | 31 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. |
| 22892 | 2009-06-05 09:46:49.101 | pduarte | 2.2 | 2.3 | 31 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,30x10^(-4)mbar. Pre-Programmed H and V field. |
| 22891 | 2009-06-05 09:39:21.143 | pduarte | 2.2 | 2.2 | 31 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,30x10^(-4)mbar. Pre-Programmed H and V field. |
| 22890 | 2009-06-05 09:31:38.081 | pduarte | 1.8 | 2.2 | 31 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,30x10^(-4)mbar. Pre-Programmed H and V field. |
| 22889 | 2009-06-05 09:23:16.076 | pduarte | 1.4 | 2.1 | 31 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,30x10^(-4)mbar. Pre-Programmed H and V field. |
| 22888 | 2009-06-05 09:17:53.184 | pduarte | 1.2 | 2.2 | 15 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,30x10^(-4)mbar. Pre-Programmed H and V field. |
| 22887 | 2009-06-05 09:11:49.784 | pduarte | 1.2 | 2.2 | 15 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,30x10^(-4)mbar. Pre-Programmed H and V field. |
| 22886 | 2009-06-05 09:06:11.954 | pduarte | 1.2 | 2 | 16 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,20x10^(-4)mbar. Pre-Programmed H and V field. |