Session aimRFA tests
Session day2009-06-05Operatorpduarte
Session IDISTTOK_200965_1Coordinatorpduarte

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
229142009-06-05 12:02:46.625pduarte3.12.33140 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. ATCA acquisition tests.
229132009-06-05 11:56:46.333pduarte3.12.33140 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. ATCA acquisition tests.
229122009-06-05 11:51:21.076pduarte3.12.33140 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. ATCA acquisition tests.
229112009-06-05 11:45:40.374pduarte3.12.23140 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. ATCA acquisition tests.
229102009-06-05 11:39:17.007pduarte3.12.23140 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. ATCA acquisition tests.
229092009-06-05 11:33:50.518pduarte3.12.33140 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. ATCA acquisition tests.
229082009-06-05 11:28:03.028pduarte001ELCO circuit breaker failure
229072009-06-05 11:22:35.425pduarte3.12.33140 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. ATCA acquisition tests.
229062009-06-05 11:16:36.647pduarte3.12.33140 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. ATCA acquisition tests.
229052009-06-05 11:10:38.767pduarte32.33140 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. ATCA acquisition tests.
229042009-06-05 11:02:53.666pduarte001ELCO circuit breaker failure
229032009-06-05 10:56:38.45pduarte3.22.23140 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. ATCA acquisition tests.
229022009-06-05 10:51:11.046pduarte3.12.23140 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. ATCA acquisition tests.
229012009-06-05 10:44:52.276pduarte32.23140 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. ATCA acquisition tests.
229002009-06-05 10:38:54.595pduarte001ELCO circuit breaker failure
228992009-06-05 10:33:26.07pduarte3.12.23140 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. ATCA acquisition tests.
228982009-06-05 10:27:19.322pduarte32.23140 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. ATCA acquisition tests.
228972009-06-05 10:21:19.668pduarte2.92.13140 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. ATCA acquisition tests.
228962009-06-05 10:14:50.305pduarte32.13140 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. ATCA acquisition tests.
228952009-06-05 10:06:02.894pduarte2.82.13140 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. ATCA acquisition tests.
228942009-06-05 09:59:48.004pduarte2.62.33140 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. ATCA acquisition tests.
228932009-06-05 09:53:58.257pduarte2.52.33140 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field.
228922009-06-05 09:46:49.101pduarte2.22.33140 turns primary. R = 0,4ohm. ELCO = 190V. P=1,30x10^(-4)mbar. Pre-Programmed H and V field.
228912009-06-05 09:39:21.143pduarte2.22.23140 turns primary. R = 0,4ohm. ELCO = 190V. P=1,30x10^(-4)mbar. Pre-Programmed H and V field.
228902009-06-05 09:31:38.081pduarte1.82.23140 turns primary. R = 0,4ohm. ELCO = 190V. P=1,30x10^(-4)mbar. Pre-Programmed H and V field.
228892009-06-05 09:23:16.076pduarte1.42.13140 turns primary. R = 0,4ohm. ELCO = 190V. P=1,30x10^(-4)mbar. Pre-Programmed H and V field.
228882009-06-05 09:17:53.184pduarte1.22.21540 turns primary. R = 0,4ohm. ELCO = 190V. P=1,30x10^(-4)mbar. Pre-Programmed H and V field.
228872009-06-05 09:11:49.784pduarte1.22.21540 turns primary. R = 0,4ohm. ELCO = 190V. P=1,30x10^(-4)mbar. Pre-Programmed H and V field.
228862009-06-05 09:06:11.954pduarte1.221640 turns primary. R = 0,4ohm. ELCO = 190V. P=1,20x10^(-4)mbar. Pre-Programmed H and V field.