Session aimATCA tomography tests.
Session day2009-07-24Operatorpduarte
Session IDISTTOK_2009724_1Coordinatorpduarte

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
232682009-07-24 16:02:13.594pduarte2.32.22740 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed V field. ATCA acquisition test 10kS/s node and 2MS/s. Tomo feedback. kp=850. ki=210, kd=1312. AC
232672009-07-24 15:52:05.642pduarte000ELCO circuit breaker failure
232662009-07-24 15:45:09.666pduarte2.62.12740 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed V field. ATCA acquisition test 10kS/s node and 2MS/s. Tomo feedback. kp=850. ki=210, kd=1312.
232652009-07-24 15:34:08.58pduarte2.52.12740 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed V field. ATCA acquisition test 10kS/s node and 2MS/s. Tomo feedback. kp=850. ki=210, kd=1312.
232642009-07-24 15:27:56.431pduarte2.422740 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed V field. ATCA acquisition test 10kS/s node and 2MS/s. Tomo feedback. kp=850. ki=210, kd=1312.
232632009-07-24 15:17:14.497pduarte222740 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed V field. ATCA acquisition test 10kS/s node and 2MS/s. Tomo feedback. kp=1050. ki=210, kd=1312.
232622009-07-24 15:09:04.59pduarte1.62.15140 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed V field. ATCA acquisition test 10kS/s node and 2MS/s. Tomo feedback. kp=1050. ki=210, kd=1312. AC
232612009-07-24 15:00:09.41pduarte000MARTe segmentation fault
232602009-07-24 14:52:30.558pduarte1.31.72740 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed V field. ATCA acquisition test 10kS/s node and 2MS/s. Tomo feedback. kp=1050. ki=210, kd=1312.
232592009-07-24 14:43:40.053pduarte2.52.12740 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed V field. ATCA acquisition test 10kS/s node and 2MS/s. Tomo feedback. kp=1050. ki=210, kd=1312.
232582009-07-24 14:34:28.778pduarte1.32840 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed V field. ATCA acquisition test 10kS/s node and 2MS/s. Tomo feedback. kp=1050. ki=210, kd=1312.
232572009-07-24 14:28:15.097pduarte1.722740 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed V field. ATCA acquisition test 10kS/s node and 2MS/s. Tomo feedback. kp=1050. ki=210, kd=1312.
232562009-07-24 14:21:58.725pduarte2.52.32740 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed V field. ATCA acquisition test 10kS/s node and 2MS/s. Tomo feedback. kp=1050.
232552009-07-24 14:15:07.114pduarte1.92.35140 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed V field. ATCA acquisition test 10kS/s node and 2MS/s. Tomo feedback. kp=1050. x setpoint=0mm.
232542009-07-24 14:05:25.677pduarte1.12.35140 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed V field. ATCA acquisition test 10kS/s node and 2MS/s. Tomo feedback. kp=1050. x setpoint=0mm.
232532009-07-24 13:58:28.994pduarte12.32740 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed V field. ATCA acquisition test 10kS/s node and 2MS/s. Tomo feedback. kp=1050. x setpoint=-10mm.
232522009-07-24 13:51:15.215pduarte0.92.35140 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed V field. ATCA acquisition test 10kS/s node and 2MS/s. Tomo feedback. kp=1050. x setpoint=-10mm.
232512009-07-24 13:45:15.685pduarte000PRECO failures
232502009-07-24 10:52:24.443pduarte22.55140 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed V field. ATCA acquisition test 10kS/s node and 2MS/s. Tomo feedback. kp=1050. x setpoint=-10mm. AC
232492009-07-24 10:44:59.551pduarte1.22.55140 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed V field. ATCA acquisition test 10kS/s node and 2MS/s. Tomo feedback. kp=1050. x setpoint=-10mm. AC
232482009-07-24 10:35:37.137pduarte0.82.35140 turns primary. R = 0,4ohm. ELCO = 190V. P=1,20x10^(-4)mbar. Pre-Programmed V field. ATCA acquisition test 10kS/s node and 2MS/s. Tomo feedback. kp=1050. x setpoint=-10mm. AC