Session aimATCA tomography tests. E-probes
Session day2009-07-29Operatorpduarte
Session IDISTTOK_2009729_1Coordinatorpduarte

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
233412009-07-29 16:16:11.72pduarte3.12.65140 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=65mm. AC
233402009-07-29 16:10:45.583pduarte3.62.72740 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=69mm.
233392009-07-29 16:05:08.936pduarte3.62.72740 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=73mm.
233382009-07-29 15:59:43.586pduarte3.52.75140 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=77mm. AC
233372009-07-29 15:54:18.225pduarte3.52.75140 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=81mm. AC
233362009-07-29 15:48:27.956pduarte3.32.65140 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=85mm. AC
233352009-07-29 15:42:32.887pduarte2.722240 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H field. ATCA acq test 10kS/s node and 2MS/s. V field tomo feedback. e-probe=85mm. IHORIZ crash
233342009-07-29 15:33:25.632pduarte3.32.65140 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H field. ATCA acq test 10kS/s node and 2MS/s. V field tomo feedback. e-probe=85mm - NO DATA. AC
233332009-07-29 15:28:02.37pduarte3.32.65140 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H field. ATCA acq test 10kS/s node and 2MS/s. V field tomo feedback. e-probe=89mm. AC
233322009-07-29 15:22:36.32pduarte3.22.42740 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H field. ATCA acq test 10kS/s node and 2MS/s. V field tomo feedback. e-probre=93mm.
233312009-07-29 15:17:14.81pduarte3.22.42740 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H field. ATCA acq test 10kS/s node and 2MS/s. V field tomo feedback. e-probre=97mm.
233302009-07-29 15:07:59.616pduarte3.22.65140 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H field. ATCA acq test 10kS/s node and 2MS/s. V field tomo feedback. e-probre=70mm. AC*
233292009-07-29 15:01:40.847pduarte32.55140 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H field. ATCA acq test 10kS/s node and 2MS/s. V field tomo feedback. e-probre=70mm. AC*
233282009-07-29 14:50:57.027pduarte000PRECO failure
233272009-07-29 14:35:43.256pduarte000ELCO circuit breaker failure
233262009-07-29 14:29:03.101pduarte32.55140 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H field. ATCA acq test 10kS/s node and 2MS/s. V field tomo feedback. e-probre=70mm. AC*
233252009-07-29 14:23:01.225pduarte2.82.12740 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H field. ATCA acq test 10kS/s node and 2MS/s. V field tomo feedback. e-probre=70mm.
233242009-07-29 14:11:34.727pduarte2.72.12740 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H field. ATCA acq test 10kS/s node and 2MS/s. V field tomo feedback.
233232009-07-29 14:05:47.609pduarte000PRECO failure
233222009-07-29 13:55:26.491pduarte2.622740 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H field. ATCA acq test 10kS/s node and 2MS/s. V field tomo feedback. e-probre=70mm.
233212009-07-29 13:48:08.322pduarte2.522740 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H field. ATCA acq test 10kS/s node and 2MS/s. V field tomo feedback. e-probre=75mm.
233202009-07-29 13:42:19.147pduarte2.51.92740 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H field. ATCA acq test 10kS/s node and 2MS/s. V field tomo feedback. e-probre=75mm.
233192009-07-29 13:32:57.431pduarte2.31.72740 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H field. ATCA acq test 10kS/s node and 2MS/s. V field tomo feedback. e-probre=75mm.
233182009-07-29 13:25:17.967pduarte1.81.52740 turns primary. R = 0,4ohm. ELCO = 190V. P=1,30x10^(-4)mbar. Pre-Programmed H field. ATCA acq test 10kS/s node and 2MS/s. V field tomo feedback. e-probre=75mm.