Session aimRFA test. New vertical power supply controled by ATCA
Session day2009-07-02Operatorpduarte
Session IDISTTOK_200972_2Coordinatorpduarte

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
230852009-07-02 16:20:05.218pduarte0010IVERT failure
230842009-07-02 16:13:22.982pduarte3.72.82.940 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. New IVERT controlled by ATCA.
230832009-07-02 16:07:31.453pduarte3.72.82740 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. New IVERT controlled by ATCA.
230822009-07-02 16:01:18.339pduarte31.51140 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. New IVERT controlled by ATCA.
230812009-07-02 15:55:27.302pduarte3.72.82740 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. New IVERT controlled by ATCA.
230802009-07-02 15:50:04.18pduarte3.62.82740 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. New IVERT controlled by ATCA.
230792009-07-02 15:27:56.772pduarte000new IVERT failure
230782009-07-02 15:21:28.858pduarte31.511new IVERT failure
230772009-07-02 15:15:49.344pduarte3211new IVERT failure
230762009-07-02 15:09:17.798pduarte3.72.82740 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. New IVERT controlled by ATCA.
230752009-07-02 15:03:22.661pduarte3.62.52740 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. New IVERT controlled by ATCA.
230742009-07-02 14:57:07.824pduarte3.52.62740 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. New IVERT controlled by ATCA.
230732009-07-02 14:50:48.441pduarte3.62.52740 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. New IVERT controlled by ATCA.
230722009-07-02 14:44:43.817pduarte3.82.72740 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. New IVERT controlled by ATCA.
230712009-07-02 14:34:04.329pduarte42.95040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. New IVERT controlled by ATCA. AC
230702009-07-02 14:28:17.209pduarte3.92.72740 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. New IVERT controlled by ATCA.
230692009-07-02 14:22:53.204pduarte000PRECO failure
230682009-07-02 14:16:48.399pduarte432740 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. New IVERT controlled by ATCA.
230672009-07-02 14:11:07.885pduarte42.82740 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. New IVERT controlled by ATCA.
230662009-07-02 14:02:38.418pduarte4.22.92740 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. New IVERT controlled by ATCA.
230652009-07-02 13:56:07.623pduarte432740 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. New IVERT controlled by ATCA.
230642009-07-02 13:50:34.059pduarte3.82.72740 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. New IVERT controlled by ATCA.
230632009-07-02 13:43:54.534pduarte3.72.52740 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. New IVERT controlled by ATCA.
230622009-07-02 13:35:51.743pduarte435140 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field. New IVERT controlled by ATCA. AC
230612009-07-02 13:28:58.222pduarte3.92.82740 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field. New IVERT controlled by ATCA.
230602009-07-02 13:22:24.253pduarte43540 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field. New IVERT controlled by ATCA. AC*
230592009-07-02 13:14:37.934pduarte3.52.85140 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field. New IVERT controlled by ATCA.
230582009-07-02 13:07:15.324pduarte2.525140 turns primary. R = 0,4ohm. ELCO = 190V. P=1,20x10^(-4)mbar. Pre-Programmed H and V field. New IVERT controlled by ATCA.
230572009-07-02 13:00:51.641pduarte225040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,20x10^(-4)mbar. Pre-Programmed H and V field. New IVERT controlled by ATCA.