Shot
|
Time
|
Operator
|
Iplasma(kA)
|
n(1018m-3)
|
Duration (ms)
|
Pre/post shot comments
|
| 23373 | 2009-07-30 15:56:45.505 | pduarte | 2.7 | 2 | 42 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,80x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=75mm. x setpoint. AC |
| 23372 | 2009-07-30 15:43:23.336 | pduarte | 2.7 | 2 | 35 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,80x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=75mm. x setpoint. AC |
| 23371 | 2009-07-30 15:36:20.241 | pduarte | 2.7 | 2.4 | 42 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,80x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=75mm. x setpoint. AC |
| 23370 | 2009-07-30 15:28:57.223 | pduarte | 2.7 | 2.3 | 42 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,80x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=75mm. x setpoint. AC |
| 23369 | 2009-07-30 15:22:35.418 | pduarte | 2.6 | 2 | 22 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,80x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=75mm. x setpoint. |
| 23368 | 2009-07-30 15:11:46.979 | pduarte | 2.7 | 2.5 | 42 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,80x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=75mm - no data. x setpoint. AC |
| 23367 | 2009-07-30 15:05:53.196 | pduarte | 2.7 | 2.5 | 42 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,80x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=75mm. x setpoint. AC |
| 23366 | 2009-07-30 14:59:17.678 | pduarte | 2.7 | 2.6 | 42 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,80x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=75mm. x setpoin=0mm. AC |
| 23365 | 2009-07-30 14:52:05.938 | pduarte | 2.8 | 2.4 | 80 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,80x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=75mm. x setpoin=-5mm. AC |
| 23364 | 2009-07-30 14:46:24.856 | pduarte | 2.8 | 2.1 | 80 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,80x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=75mm. x setpoin=-5mm. AC |
| 23363 | 2009-07-30 14:39:47.822 | pduarte | 2.8 | 2.2 | 80 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,80x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=75mm. x setpoin=-5mm. AC |
| 23362 | 2009-07-30 14:33:38.881 | pduarte | 2.8 | 2.2 | 80 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,80x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=75mm. x setpoin=-5mm. AC |
| 23361 | 2009-07-30 14:26:02.461 | pduarte | 2.5 | 2.4 | 80 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,80x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=75mm. x setpoin=-5mm. AC |
| 23360 | 2009-07-30 14:15:37.647 | pduarte | 0 | 0 | 2 | IHORIZ failure |
| 23359 | 2009-07-30 14:08:33.803 | pduarte | 2.7 | 2 | 58 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,80x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=75mm. x setpoin=-5mm. AC |
| 23358 | 2009-07-30 14:02:27.172 | pduarte | 2.5 | 2.2 | 42 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,80x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=75mm. x setpoin=-5mm. AC |
| 23357 | 2009-07-30 13:54:13.126 | pduarte | 2.1 | 1.5 | 22 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,80x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=75mm. x setpoin=7mm. |
| 23356 | 2009-07-30 13:46:34.989 | pduarte | 2.5 | 2 | 22 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=2,00x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=75mm. |
| 23355 | 2009-07-30 13:40:10.438 | pduarte | 2.6 | 2.2 | 42 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,80x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=75mm. AC |
| 23354 | 2009-07-30 13:33:45.545 | pduarte | 2.5 | 2 | 22 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,60x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=75mm. |
| 23353 | 2009-07-30 13:27:43.204 | pduarte | 2.5 | 2.5 | 73 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,80x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=75mm. AC |
| 23352 | 2009-07-30 13:19:48.455 | pduarte | 2.5 | 2.3 | 80 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,60x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=75mm. AC |
| 23351 | 2009-07-30 13:14:20.38 | pduarte | 2.4 | 2.8 | 22 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=75mm. |
| 23350 | 2009-07-30 13:08:19.432 | pduarte | 0 | 0 | 0 | PRECO failure |
| 23349 | 2009-07-30 13:02:00.049 | pduarte | 2.3 | 2.1 | 42 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=75mm. AC |
| 23348 | 2009-07-30 12:55:29.304 | pduarte | 2 | 2 | 39 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,60x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=75mm. |
| 23347 | 2009-07-30 12:50:04.658 | pduarte | 2 | 1.8 | 20 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,60x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=75mm. |
| 23346 | 2009-07-30 12:44:38.27 | pduarte | 1.7 | 1.8 | 39 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,60x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=75mm. AC |
| 23345 | 2009-07-30 12:38:11.755 | pduarte | 1.7 | 1.6 | 20 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=75mm. |
| 23344 | 2009-07-30 10:28:32.713 | pduarte | 1.5 | 2 | 20 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=75mm. IVERT failure |
| 23343 | 2009-07-30 10:09:47.422 | pduarte | 1.5 | 1.5 | 27 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,30x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=75mm. |