Session aimATCA tomography tests. E-probes
Session day2009-07-30Operatorpduarte
Session IDISTTOK_2009730_1Coordinatorpduarte

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
233732009-07-30 15:56:45.505pduarte2.724240 turns primary. R = 0,4ohm. ELCO = 190V. P=1,80x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=75mm. x setpoint. AC
233722009-07-30 15:43:23.336pduarte2.723540 turns primary. R = 0,4ohm. ELCO = 190V. P=1,80x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=75mm. x setpoint. AC
233712009-07-30 15:36:20.241pduarte2.72.44240 turns primary. R = 0,4ohm. ELCO = 190V. P=1,80x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=75mm. x setpoint. AC
233702009-07-30 15:28:57.223pduarte2.72.34240 turns primary. R = 0,4ohm. ELCO = 190V. P=1,80x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=75mm. x setpoint. AC
233692009-07-30 15:22:35.418pduarte2.622240 turns primary. R = 0,4ohm. ELCO = 190V. P=1,80x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=75mm. x setpoint.
233682009-07-30 15:11:46.979pduarte2.72.54240 turns primary. R = 0,4ohm. ELCO = 190V. P=1,80x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=75mm - no data. x setpoint. AC
233672009-07-30 15:05:53.196pduarte2.72.54240 turns primary. R = 0,4ohm. ELCO = 190V. P=1,80x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=75mm. x setpoint. AC
233662009-07-30 14:59:17.678pduarte2.72.64240 turns primary. R = 0,4ohm. ELCO = 190V. P=1,80x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=75mm. x setpoin=0mm. AC
233652009-07-30 14:52:05.938pduarte2.82.48040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,80x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=75mm. x setpoin=-5mm. AC
233642009-07-30 14:46:24.856pduarte2.82.18040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,80x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=75mm. x setpoin=-5mm. AC
233632009-07-30 14:39:47.822pduarte2.82.28040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,80x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=75mm. x setpoin=-5mm. AC
233622009-07-30 14:33:38.881pduarte2.82.28040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,80x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=75mm. x setpoin=-5mm. AC
233612009-07-30 14:26:02.461pduarte2.52.48040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,80x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=75mm. x setpoin=-5mm. AC
233602009-07-30 14:15:37.647pduarte002IHORIZ failure
233592009-07-30 14:08:33.803pduarte2.725840 turns primary. R = 0,4ohm. ELCO = 190V. P=1,80x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=75mm. x setpoin=-5mm. AC
233582009-07-30 14:02:27.172pduarte2.52.24240 turns primary. R = 0,4ohm. ELCO = 190V. P=1,80x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=75mm. x setpoin=-5mm. AC
233572009-07-30 13:54:13.126pduarte2.11.52240 turns primary. R = 0,4ohm. ELCO = 190V. P=1,80x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=75mm. x setpoin=7mm.
233562009-07-30 13:46:34.989pduarte2.522240 turns primary. R = 0,4ohm. ELCO = 190V. P=2,00x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=75mm.
233552009-07-30 13:40:10.438pduarte2.62.24240 turns primary. R = 0,4ohm. ELCO = 190V. P=1,80x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=75mm. AC
233542009-07-30 13:33:45.545pduarte2.522240 turns primary. R = 0,4ohm. ELCO = 190V. P=1,60x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=75mm.
233532009-07-30 13:27:43.204pduarte2.52.57340 turns primary. R = 0,4ohm. ELCO = 190V. P=1,80x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=75mm. AC
233522009-07-30 13:19:48.455pduarte2.52.38040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,60x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=75mm. AC
233512009-07-30 13:14:20.38pduarte2.42.82240 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=75mm.
233502009-07-30 13:08:19.432pduarte000PRECO failure
233492009-07-30 13:02:00.049pduarte2.32.14240 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=75mm. AC
233482009-07-30 12:55:29.304pduarte223940 turns primary. R = 0,4ohm. ELCO = 190V. P=1,60x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=75mm.
233472009-07-30 12:50:04.658pduarte21.82040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,60x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=75mm.
233462009-07-30 12:44:38.27pduarte1.71.83940 turns primary. R = 0,4ohm. ELCO = 190V. P=1,60x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=75mm. AC
233452009-07-30 12:38:11.755pduarte1.71.62040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=75mm.
233442009-07-30 10:28:32.713pduarte1.522040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=75mm. IVERT failure
233432009-07-30 10:09:47.422pduarte1.51.52740 turns primary. R = 0,4ohm. ELCO = 190V. P=1,30x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=75mm.