Session aimATCA tomography tests. AC. Poloidal E-probes
Session day2009-07-31Operatorpduarte
Session IDISTTOK_2009731_1Coordinatorpduarte

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
233842009-07-31 14:20:19.067pduarte4.532240 turns primary. R = 0,4ohm. ELCO = 190V. P=1,60x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=90mm.
233832009-07-31 14:08:40.51pduarte4.534240 turns primary. R = 0,4ohm. ELCO = 190V. P=1,60x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=90mm. AC
233822009-07-31 14:01:34.977pduarte4.534240 turns primary. R = 0,4ohm. ELCO = 190V. P=1,60x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=90mm. AC
233812009-07-31 13:41:23.027pduarte4.534240 turns primary. R = 0,4ohm. ELCO = 190V. P=1,60x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=70mm. AC
233802009-07-31 13:33:37.352pduarte4.53.34240 turns primary. R = 0,4ohm. ELCO = 190V. P=1,60x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=75mm. AC
233792009-07-31 13:26:19.82pduarte4.33.34240 turns primary. R = 0,4ohm. ELCO = 190V. P=1,60x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=80mm. AC
233782009-07-31 13:15:35.248pduarte4.23.54240 turns primary. R = 0,4ohm. ELCO = 190V. P=1,60x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=85mm. AC
233772009-07-31 13:07:40.35pduarte43.54240 turns primary. R = 0,4ohm. ELCO = 190V. P=1,60x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=90mm. AC
233762009-07-31 12:53:00.419pduarte000PRECO failures
233752009-07-31 12:46:23.661pduarte438040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=90mm. AC
233742009-07-31 12:39:45.117pduarte32.64240 turns primary. R = 0,4ohm. ELCO = 190V. P=1,30x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. e-probe=90mm. AC