Shot
|
Time
|
Operator
|
Iplasma(kA)
|
n(1018m-3)
|
Duration (ms)
|
Pre/post shot comments
|
| 23398 | 2009-08-03 14:03:50.914 | pduarte | 4 | 2.5 | 30 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. puffing. AC |
| 23397 | 2009-08-03 13:48:58.286 | pduarte | 0 | 0 | 0 | Software shot - IVERT maximum test |
| 23396 | 2009-08-03 13:19:32.41 | pduarte | 4.5 | 3.3 | 42 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. puffing. AC |
| 23395 | 2009-08-03 13:10:45.103 | pduarte | 4 | 3.3 | 42 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. puffing. AC |
| 23394 | 2009-08-03 12:59:41.985 | pduarte | 2.5 | 2 | 12 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field failure. puffing. |
| 23393 | 2009-08-03 12:53:15.719 | pduarte | 4.5 | 3.5 | 22 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. puffing. |
| 23392 | 2009-08-03 12:46:28.349 | pduarte | 4.5 | 3.3 | 42 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. puffing. AC |
| 23391 | 2009-08-03 12:33:10.469 | pduarte | 4 | 3.2 | 22 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. |
| 23390 | 2009-08-03 11:04:24.475 | pduarte | 0 | 0 | 0 | PRECO failure |
| 23389 | 2009-08-03 10:58:31.758 | pduarte | 4.5 | 3.5 | 42 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. AC |
| 23388 | 2009-08-03 10:51:21.487 | pduarte | 4 | 3.3 | 42 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. AC |
| 23387 | 2009-08-03 10:45:24.906 | pduarte | 1.5 | 2 | 7 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,30x10^(-4)mbar. Pre-Programmed H field. ATCA acq 10kS/s node and 2MS/s. V field tomo feedback. |
| 23386 | 2009-08-03 10:36:40.717 | pduarte | 0 | 0 | 0 | Software shot - IVERT maximum test |
| 23385 | 2009-08-03 10:31:28.501 | pduarte | 0 | 0 | 0 | Software shot - IVERT maximum test |