| Session aim | Machine conditioning. +-5V ATCA board test | | Session day | 2009-09-11 | Operator | pduarte | | Session ID | ISTTOK_2009911_1 | Coordinator | pduarte |
|
Shot
|
Time
|
Operator
|
Iplasma(kA)
|
n(1018m-3)
|
Duration (ms)
|
Pre/post shot comments
|
| 23488 | 2009-09-11 14:53:55.761 | pduarte | 2.5 | 2.5 | 22 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H field. V field feedback. +-5V ATCA | | 23487 | 2009-09-11 14:44:17.75 | pduarte | 2 | 2.3 | 22 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H field. V field feedback. +-5V ATCA | | 23486 | 2009-09-11 14:37:03.588 | pduarte | 2 | 2.3 | 22 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,20x10^(-4)mbar. Pre-Programmed H field. V field feedback. +-5V ATCA | | 23485 | 2009-09-11 14:26:10.111 | pduarte | 1.7 | 2.3 | 80 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,20x10^(-4)mbar. Pre-Programmed H field. V field feedback. +-5V ATCA | | 23484 | 2009-09-11 14:20:41.274 | pduarte | 0 | 0 | 1 | triggers failure. 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,20x10^(-4)mbar. Pre-Programmed H field. V field feedback. +-5V ATCA | | 23483 | 2009-09-11 14:14:12.049 | pduarte | 1.2 | 2.3 | 80 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,00x10^(-4)mbar. Pre-Programmed H field. V field feedback. +-5V ATCA | | 23482 | 2009-09-11 14:01:44.087 | pduarte | 0 | 0 | 1 | IHORIZ error. 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,00x10^(-4)mbar. Pre-Programmed H field. V field feedback. +-5V ATCA | | 23481 | 2009-09-11 09:51:47.073 | pduarte | 0 | 0 | 0 | Software shot |
|