Session aimMachine conditioning.
Session day2009-09-14Operatorpduarte
Session IDISTTOK_2009914_1Coordinatorpduarte

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
235072009-09-14 15:36:06.603pduarte332240 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H field. V field feedback.
235062009-09-14 15:29:45.655pduarte2.82.82240 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H field. V field feedback.
235052009-09-14 15:23:14.082pduarte001ELCO circuit breaker failure
235042009-09-14 15:14:51.043pduarte332240 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H field. V field feedback.
235032009-09-14 15:08:58.036pduarte332240 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H field. V field feedback.
235022009-09-14 14:58:53.942pduarte332240 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H field. V field feedback.
235012009-09-14 14:47:59.596pduarte332240 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H field. V field feedback.
235002009-09-14 14:42:13.379pduarte334040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H field. V field feedback.
234992009-09-14 14:31:15.146pduarte332240 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H field. V field feedback.
234982009-09-14 14:23:14.095pduarte32.82240 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H field. V field feedback.
234972009-09-14 14:15:53.40pduarte32.82240 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H field. V field feedback.
234962009-09-14 14:08:48.223pduarte32.72240 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H field. V field feedback.
234952009-09-14 13:54:16.529pduarte2.82.53440 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H field. V field feedback.
234942009-09-14 13:48:47.326pduarte000PRECO failure. 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,30x10^(-4)mbar. Pre-Programmed H field. V field feedback.
234932009-09-14 13:42:48.595pduarte2.62.52240 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H field. V field feedback.
234922009-09-14 13:34:59.493pduarte2.72.52240 turns primary. R = 0,4ohm. ELCO = 190V. P=1,20x10^(-4)mbar. Pre-Programmed H field. V field feedback.
234912009-09-14 13:29:27.488pduarte2.32.52240 turns primary. R = 0,4ohm. ELCO = 190V. P=1,20x10^(-4)mbar. Pre-Programmed H field. V field feedback.
234902009-09-14 13:23:22.084pduarte1.62.34240 turns primary. R = 0,4ohm. ELCO = 190V. P=1,00x10^(-4)mbar. Pre-Programmed H field. V field feedback.
234892009-09-14 13:16:46.355pduarte000PRECO failures