Session aimPoloidal array of e-probes
Session day2009-09-22Operatorpduarte
Session IDISTTOK_2009922_1Coordinatorpduarte

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
235682009-09-22 16:22:48.428pduarte3.52.82840 turns primary. R = 0,4ohm. ELCO = 190V. P=1,00x10^(-4)mbar. Pre-Programmed H field. V field feedback. e-probe=65. r setpoint=5mm
235672009-09-22 16:16:55.448pduarte3.12.52840 turns primary. R = 0,4ohm. ELCO = 190V. P=1,00x10^(-4)mbar. Pre-Programmed H field. V field feedback. e-probe=65. r setpoint=5mm
235662009-09-22 16:09:04.932pduarte4.23.52840 turns primary. R = 0,4ohm. ELCO = 190V. P=1,00x10^(-4)mbar. Pre-Programmed H field. V field feedback. e-probe=65.
235652009-09-22 16:03:00.491pduarte4.33.62840 turns primary. R = 0,4ohm. ELCO = 190V. P=1,00x10^(-4)mbar. Pre-Programmed H field. V field feedback. e-probe=70.
235642009-09-22 15:57:11.895pduarte000PRECO failure. 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,00x10^(-4)mbar. Pre-Programmed H field. V field feedback. e-probe=70.
235632009-09-22 15:50:25.094pduarte4.33.72840 turns primary. R = 0,4ohm. ELCO = 190V. P=1,00x10^(-4)mbar. Pre-Programmed H field. V field feedback. e-probe=75.
235622009-09-22 15:44:26.717pduarte2.521140 turns primary. R = 0,4ohm. ELCO = 190V. P=1,00x10^(-4)mbar. Pre-Programmed H field. e-probe=75. IVERT failure
235612009-09-22 15:38:24.981pduarte4.63.62840 turns primary. R = 0,4ohm. ELCO = 190V. P=1,00x10^(-4)mbar. Pre-Programmed H field. V field feedback. e-probe=95
235602009-09-22 15:31:54.127pduarte4.73.72840 turns primary. R = 0,4ohm. ELCO = 190V. P=1,00x10^(-4)mbar. Pre-Programmed H field. V field feedback. e-probe=90
235592009-09-22 15:24:40.686pduarte4.53.62840 turns primary. R = 0,4ohm. ELCO = 190V. P=1,00x10^(-4)mbar. Pre-Programmed H field. V field feedback. e-probe=85
235582009-09-22 15:19:04.546pduarte4.73.72840 turns primary. R = 0,4ohm. ELCO = 190V. P=1,00x10^(-4)mbar. Pre-Programmed H field. V field feedback. e-probe=80
235572009-09-22 15:13:12.181pduarte4.63.52840 turns primary. R = 0,4ohm. ELCO = 190V. P=1,00x10^(-4)mbar. Pre-Programmed H field. V field feedback. e-probe=80
235562009-09-22 15:01:29.038pduarte4.53.85240 turns primary. R = 0,4ohm. ELCO = 190V. P=1,00x10^(-4)mbar. Pre-Programmed H field. V field feedback. e-probe=75
235552009-09-22 14:54:32.573pduarte4.53.42840 turns primary. R = 0,4ohm. ELCO = 190V. P=1,00x10^(-4)mbar. Pre-Programmed H field. V field feedback. e-probe=75
235542009-09-22 14:48:32.421pduarte000PRECO failure
235532009-09-22 14:37:37.77pduarte4.43.62840 turns primary. R = 0,4ohm. ELCO = 190V. P=1,00x10^(-4)mbar. Pre-Programmed H field. V field feedback. e-probe=65
235522009-09-22 14:29:44.353pduarte4.642840 turns primary. R = 0,4ohm. ELCO = 190V. P=1,00x10^(-4)mbar. Pre-Programmed H field. V field feedback.
235512009-09-22 14:22:57.462pduarte4.43.62840 turns primary. R = 0,4ohm. ELCO = 190V. P=1,00x10^(-4)mbar. Pre-Programmed H field. V field feedback.
235502009-09-22 14:08:31.932pduarte4.53.72840 turns primary. R = 0,4ohm. ELCO = 190V. P=1,00x10^(-4)mbar. Pre-Programmed H field. V field feedback.
235492009-09-22 13:54:15.714pduarte4.74.32840 turns primary. R = 0,4ohm. ELCO = 190V. P=1,00x10^(-4)mbar. Pre-Programmed H field. V field feedback.
235482009-09-22 13:45:43.639pduarte4.742840 turns primary. R = 0,4ohm. ELCO = 190V. P=1,00x10^(-4)mbar. Pre-Programmed H field. V field feedback.
235472009-09-22 13:36:59.866pduarte4.542840 turns primary. R = 0,4ohm. ELCO = 190V. P=1,00x10^(-4)mbar. Pre-Programmed H field. V field feedback.
235462009-09-22 13:28:55.277pduarte43.85240 turns primary. R = 0,4ohm. ELCO = 190V. P=1,00x10^(-4)mbar. Pre-Programmed H field. V field feedback. AC*
235452009-09-22 13:22:19.307pduarte335240 turns primary. R = 0,4ohm. ELCO = 190V. P=1,00x10^(-4)mbar. Pre-Programmed H field. V field feedback.