Session aimPhotodiode and e-probes correlation tests
Session day2009-09-29Operatorpduarte
Session IDISTTOK_2009929_1Coordinatorpduarte

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
236342009-09-29 14:08:28.577pduarte4.23.35240 turns primary. R = 0,4ohm. ELCO = 190V. P=1,00x10^(-4)mbar. Pre-Programmed H field. V field feedback. PD on ch32, e-probes on 28-30. position=0. battery
236332009-09-29 14:00:12.516pduarte43.22840 turns primary. R = 0,4ohm. ELCO = 190V. P=1,00x10^(-4)mbar. Pre-Programmed H field. V field feedback. PD on ch32, e-probes on 28-30. position=0. battery
236322009-09-29 13:39:15.414pduarte4.23.45240 turns primary. R = 0,4ohm. ELCO = 190V. P=1,00x10^(-4)mbar. Pre-Programmed H field. V field feedback. PD on ch32, e-probes on 28-30. position=0
236312009-09-29 13:32:42.105pduarte43.32840 turns primary. R = 0,4ohm. ELCO = 190V. P=1,00x10^(-4)mbar. Pre-Programmed H field. V field feedback. PD on ch32, e-probes on 28-30. position=0
236302009-09-29 13:13:13.466pduarte43.35240 turns primary. R = 0,4ohm. ELCO = 190V. P=1,00x10^(-4)mbar. Pre-Programmed H field. V field feedback. PD on ch32, e-probes on 28-30. position=0,25
236292009-09-29 13:06:27.572pduarte3.535240 turns primary. R = 0,4ohm. ELCO = 190V. P=1,00x10^(-4)mbar. Pre-Programmed H field. V field feedback. PD on ch32, e-probes on 28-30. position=0,25
236282009-09-29 13:00:56.714pduarte2.2215IVERT failure. 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,00x10^(-4)mbar. Pre-Programmed H field. PD on ch32, e-probes on 28-30. position=0,25
236272009-09-29 09:26:37.337pduarte4.53.75240 turns primary. R = 0,4ohm. ELCO = 190V. P=1,00x10^(-4)mbar. Pre-Programmed H field. V field feedback. PD on ch32, e-probes on 28-30. position=0,5
236262009-09-29 09:21:05.917pduarte4.53.55240 turns primary. R = 0,4ohm. ELCO = 190V. P=1,00x10^(-4)mbar. Pre-Programmed H field. V field feedback. PD on ch32, e-probes on 28-30. position=0,5
236252009-09-29 09:13:17.792pduarte43.35240 turns primary. R = 0,4ohm. ELCO = 190V. P=1,00x10^(-4)mbar. Pre-Programmed H field. V field feedback. PD on ch32, e-probes on 28-30. position=1,0
236242009-09-29 09:05:57.463pduarte3.73.25240 turns primary. R = 0,4ohm. ELCO = 190V. P=1,00x10^(-4)mbar. Pre-Programmed H field. V field feedback. PD on ch32, e-probes on 28-30. position=1,0
236232009-09-29 08:59:48.622pduarte3.532840 turns primary. R = 0,4ohm. ELCO = 190V. P=1,00x10^(-4)mbar. Pre-Programmed H field. V field feedback. PD on ch32, e-probes on 28-30. position=0,75
236222009-09-29 08:53:05.827pduarte2.82.65240 turns primary. R = 0,4ohm. ELCO = 190V. P=1,00x10^(-4)mbar. Pre-Programmed H field. V field feedback. PD on ch32, e-probes on 28-30. position=0,75
236212009-09-29 08:45:06.215pduarte1.522040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,00x10^(-4)mbar. Pre-Programmed H field. V field feedback.