Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
244882010-01-11 17:08:26.325pduarte1.52.53040 turns primary. R = 0,4ohm. ELCO = 210V. P=1,4x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=65.
244872010-01-11 17:02:37.211pduarte11.57Plasma position node failure. 40 turns primary. R = 0,4ohm. ELCO = 210V. P=1,4x10^(-4)mbar. Ga sample r=65.
244862010-01-11 16:55:28.659pduarte1.52.33040 turns primary. R = 0,4ohm. ELCO = 210V. P=1,4x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=65.
244852010-01-11 16:50:00.432pduarte1.32.23040 turns primary. R = 0,4ohm. ELCO = 210V. P=1,4x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=65.
244842010-01-11 16:42:09.525pduarte1.22.23040 turns primary. R = 0,4ohm. ELCO = 210V. P=1,4x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=65.
244832010-01-11 16:36:15.493pduarte123040 turns primary. R = 0,4ohm. ELCO = 210V. P=1,2x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=65.
244822010-01-11 16:30:23.583pduarte0.81.71840 turns primary. R = 0,4ohm. ELCO = 210V. P=1,2x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=65.
244812010-01-11 16:23:51.989pduarte000ELCO circuit breaker failure
244802010-01-11 16:17:00.117pduarte0.61.21840 turns primary. R = 0,4ohm. ELCO = 210V. P=1,3x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=65.
244792010-01-11 16:09:46.801pduarte0.52.11540 turns primary. R = 0,4ohm. ELCO = 210V. P=1,4x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=65.
244782010-01-11 16:04:18.319pduarte00140 turns primary. R = 0,4ohm. ELCO = 210V. P=1,4x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=65.
244772010-01-11 15:58:04.098pduarte00140 turns primary. R = 0,4ohm. ELCO = 210V. P=1,4x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=65.
244762010-01-11 15:52:03.634pduarte00140 turns primary. R = 0,4ohm. ELCO = 200V. P=1,8x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=65.
244752010-01-11 15:46:09.273pduarte00140 turns primary. R = 0,4ohm. ELCO = 200V. P=1,1x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=65.
244742010-01-11 15:38:40.872pduarte00140 turns primary. R = 0,4ohm. ELCO = 190V. P=1,2x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=65.
244732010-01-11 15:31:40.951pduarte00140 turns primary. R = 0,4ohm. ELCO = 180V. P=1,3x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=65.