Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
246332010-01-15 17:32:50.889pduarte433040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,5x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=68.
246322010-01-15 17:27:23.083pduarte3.933040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,5x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=68.
246312010-01-15 17:21:19.643pduarte433040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,5x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=68.
246302010-01-15 17:15:48.702pduarte433040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,5x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=68.
246292010-01-15 17:09:22.608pduarte433040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,5x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=68.
246282010-01-15 17:03:49.451pduarte43.13040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,5x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=68.
246272010-01-15 16:58:23.162pduarte3.93.23040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,5x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=68.
246262010-01-15 16:52:38.97pduarte3.93.13040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,5x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=68.
246252010-01-15 16:46:58.731pduarte3.93.13040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,6x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=68.
246242010-01-15 16:41:15.646pduarte3.83.33040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,6x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=68.
246232010-01-15 16:26:14.734pduarte4.13.33040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,6x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=68.
246222010-01-15 16:20:33.508pduarte43.33040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,6x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=68.
246212010-01-15 16:13:56.437pduarte4.13.43040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,6x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=68.
246202010-01-15 16:07:33.017pduarte4.23.43040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,6x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=68.
246192010-01-15 16:01:09.837pduarte4.23.53040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,6x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=68.
246182010-01-15 15:54:58.619pduarte4.23.33040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,6x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=68. C (910nm) photodiode on atcaB1.ch27, probe=0,0
246172010-01-15 15:48:19.057pduarte4.23.53040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,7x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=68. C (910nm) photodiode on atcaB1.ch27, probe=0,0
246162010-01-15 15:42:57.456pduarte4.23.63040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,7x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=68. C (910nm) photodiode on atcaB1.ch27, probe=0,0
246152010-01-15 15:35:25.921pduarte4.43.53040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,7x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=68. C (910nm) photodiode on atcaB1.ch27, probe=0,5
246142010-01-15 15:29:13.528pduarte4.43.63040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,7x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=68. C (910nm) photodiode on atcaB1.ch27, probe=0,5
246132010-01-15 15:23:10.49pduarte4.43.63040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,7x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=68. C (910nm) photodiode on atcaB1.ch27, probe=0,5
246122010-01-15 15:17:45.562pduarte4.53.53040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,7x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=68. C (910nm) photodiode on atcaB1.ch27, probe=0,5
246112010-01-15 15:11:39.249pduarte4.53.63040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,7x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=68. C (910nm) photodiode on atcaB1.ch27, probe=0,5
246102010-01-15 15:06:13.161pduarte4.63.63040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,7x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=68. C (910nm) photodiode on atcaB1.ch27, probe=0,5
246092010-01-15 15:00:52.077pduarte4.63.53040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,7x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=68. C (910nm) photodiode on atcaB1.ch27, probe=0,5
246082010-01-15 14:55:17.636pduarte4.73.63040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,7x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=68. nothing on atcaB1.ch27, probe=0,5
246072010-01-15 14:49:46.49pduarte4.73.63040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,7x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=68. C2 photodiode on atcaB1.ch27, probe=0,5
246062010-01-15 14:43:40.693pduarte53.73040 turns primary. R = 0,4ohm. ELCO = 200V. P=1,7x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=68. C2 photodiode on atcaB1.ch27, probe=0,5
246052010-01-15 14:38:16.073pduarte53.73040 turns primary. R = 0,4ohm. ELCO = 200V. P=1,7x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=68. C2 photodiode on atcaB1.ch27, probe=0,5
246042010-01-15 14:30:54.399pduarte53.73040 turns primary. R = 0,4ohm. ELCO = 200V. P=1,7x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=68. C2 photodiode on atcaB1.ch27, probe=0,5
246032010-01-15 14:25:31.286pduarte4.93.73040 turns primary. R = 0,4ohm. ELCO = 200V. P=1,5x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=68. C2 photodiode on atcaB1.ch27, probe=0,5
246022010-01-15 14:19:58.008pduarte4.93.93040 turns primary. R = 0,4ohm. ELCO = 200V. P=1,5x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=68. C2 photodiode on atcaB1.ch27, probe=0,5
246012010-01-15 14:14:31.81pduarte4.73.83040 turns primary. R = 0,4ohm. ELCO = 200V. P=1,5x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=68. C2 photodiode on atcaB1.ch27, probe=0,5
246002010-01-15 14:07:42.119pduarte4.73.73040 turns primary. R = 0,4ohm. ELCO = 200V. P=1,5x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=68. C2 photodiode on atcaB1.ch27, probe=0,5
245992010-01-15 13:59:00.187pduarte4.73.93040 turns primary. R = 0,4ohm. ELCO = 200V. P=1,5x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=68. C2 photodiode on atcaB1.ch27, probe=0,5
245982010-01-15 13:47:27.339pduarte4.43.93040 turns primary. R = 0,4ohm. ELCO = 200V. P=1,5x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=68.
245972010-01-15 13:35:34.971pduarte443040 turns primary. R = 0,4ohm. ELCO = 200V. P=1,5x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=68.
245962010-01-15 12:23:07.132pduarte4.53.63040 turns primary. R = 0,4ohm. ELCO = 200V. P=1,5x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=68.
245952010-01-15 11:54:44.566pduarte000PRECO failure. thyristors..
245942010-01-15 11:48:58.47pduarte000PRECO failure.
245932010-01-15 11:42:15.212pduarte000ELCO circuit breaker failure
245922010-01-15 11:36:12.859pduarte4.53.54840 turns primary. R = 0,4ohm. ELCO = 200V. P=1,6x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=68.
245912010-01-15 11:30:48.058pduarte4.53.55040 turns primary. R = 0,4ohm. ELCO = 200V. P=1,5x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=68.
245902010-01-15 11:25:17.65pduarte435140 turns primary. R = 0,4ohm. ELCO = 200V. P=1,4x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=68.
245892010-01-15 11:19:16.013pduarte435140 turns primary. R = 0,4ohm. ELCO = 200V. P=1,2x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=68.