Session aimLiquid Gallium exposition
Session day2010-01-18Operatorpduarte
Session IDISTTOK_2010118_2Coordinatorpduarte

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
246552010-01-18 17:16:21.253pduarte000Software shot - IR sensor calibration with Ga jet - Ga temp = 110ºC
246542010-01-18 16:18:33.305pduarte3.92.93040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,5x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=68.
246532010-01-18 16:12:43.269pduarte3.933040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,5x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=68.
246522010-01-18 16:07:17.546pduarte3.933040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,5x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=68.
246512010-01-18 16:01:29.342pduarte3.933040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,4x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=68.
246502010-01-18 15:50:37.96pduarte000Software shot - IR sensor calibration with Ga jet - Ga temp = 100ºC
246492010-01-18 15:45:04.084pduarte3.92.93040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,4x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=68.
246482010-01-18 15:39:32.259pduarte42.93040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,4x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=68.
246472010-01-18 15:28:32.493pduarte42.93040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,4x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=68.
246462010-01-18 15:23:10.928pduarte3.72.83040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,4x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=68.
246452010-01-18 15:17:11.866pduarte3.92.93040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,4x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=68.
246442010-01-18 15:11:49.492pduarte3.72.93040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,4x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=68.
246432010-01-18 15:06:25.686pduarte3.833040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,4x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=68.
246422010-01-18 15:00:55.902pduarte3.83.13040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,4x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=68.
246412010-01-18 14:54:48.447pduarte3.633040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,4x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=68.
246402010-01-18 14:48:11.007pduarte3.12.63040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,3x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=68.
246392010-01-18 14:42:38.383pduarte2.72.53040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,3x10^(-4)mbar. Pre-Programmed V and H field. Ga sample r=68.