Session aimGa jet and IR sensor
Session day2010-01-19Operatorpduarte
Session IDISTTOK_2010119_1Coordinatorpduarte

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
246672010-01-19 12:08:28.586pduarte4.63.53040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,6x10^(-4)mbar. Pre-Programmed V and H field. Ga injector=60
246662010-01-19 12:01:47.488pduarte4.63.43040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,6x10^(-4)mbar. Pre-Programmed V and H field.
246652010-01-19 11:55:07.677pduarte000ELCO circuit breaker failure
246642010-01-19 11:45:03.445pduarte4.73.33040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,6x10^(-4)mbar. Pre-Programmed V and H field. Ga injector=65
246632010-01-19 11:33:42.334pduarte4.53.53040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,4x10^(-4)mbar. Pre-Programmed V and H field. Ga injector=59
246622010-01-19 11:25:33.219pduarte43.53040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,4x10^(-4)mbar. Pre-Programmed V and H field. Ga injector=59
246612010-01-19 11:16:34.816pduarte43.53040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,4x10^(-4)mbar. Pre-Programmed V and H field. Ga injector=60
246602010-01-19 11:06:02.03pduarte43.53040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,4x10^(-4)mbar. Pre-Programmed V and H field. Ga injector=62
246592010-01-19 10:58:54.492pduarte4.22.93040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,4x10^(-4)mbar. Pre-Programmed V and H field.
246582010-01-19 10:48:30.823pduarte4.13.13040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,4x10^(-4)mbar. Pre-Programmed V and H field.
246572010-01-19 10:42:30.559pduarte3.92.93040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,4x10^(-4)mbar. Pre-Programmed V and H field.
246562010-01-19 10:34:49.783pduarte3.52.83040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,2x10^(-4)mbar. Pre-Programmed V and H field.