Session aimGa jet and IR sensor
Session day2010-01-21Operatorpduarte
Session IDISTTOK_2010121_1Coordinatorpduarte

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
247302010-01-21 12:30:54.008pduarte53.53040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,8x10^(-4)mbar. Pre-Programmed V and H field.
247292010-01-21 12:24:54.702pduarte53.53040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,8x10^(-4)mbar. Pre-Programmed V and H field.
247282010-01-21 12:17:25.061pduarte53.53040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,8x10^(-4)mbar. Pre-Programmed V and H field.
247272010-01-21 12:12:01.964pduarte53.53040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,8x10^(-4)mbar. Pre-Programmed V and H field.
247262010-01-21 12:01:49.673pduarte3.733040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,8x10^(-4)mbar. Pre-Programmed V and H field. Ga injector=60. plasma out
247252010-01-21 11:51:42.573pduarte4.73.63040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,8x10^(-4)mbar. Pre-Programmed V and H field. Ga injector=60
247242010-01-21 11:40:52.988pduarte4.73.53040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,5x10^(-4)mbar. Pre-Programmed V and H field. Ga injector=62
247232010-01-21 11:32:54.422pduarte4.53.53040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,5x10^(-4)mbar. Pre-Programmed V and H field. Ga injector=60
247222010-01-21 11:18:22.404pduarte4.23.63040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,5x10^(-4)mbar. Pre-Programmed V and H field. Ga injector=60
247212010-01-21 11:09:25.348pduarte000PRECO failures
247202010-01-21 11:00:40.152pduarte4.13.53040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,4x10^(-4)mbar. Pre-Programmed V and H field. Ga injector=60
247192010-01-21 10:54:37.451pduarte3.52.63040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,4x10^(-4)mbar. Pre-Programmed V and H field.
247182010-01-21 10:48:46.141pduarte001ELCO circuit breaker failure
247172010-01-21 10:42:33.761pduarte43.13040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,2x10^(-4)mbar. Pre-Programmed V and H field.