Shot
|
Time
|
Operator
|
Iplasma(kA)
|
n(1018m-3)
|
Duration (ms)
|
Pre/post shot comments
|
| 24775 | 2010-01-25 14:52:13.358 | pduarte | 0 | 0 | 0 | Software shots - New vertical field power supply tests. |
| 24774 | 2010-01-25 14:43:45.39 | pduarte | 0 | 0 | 0 | Software shots - New vertical field power supply tests. |
| 24773 | 2010-01-25 14:20:31.038 | pduarte | 0 | 0 | 0 | Software shots - New vertical field power supply tests. |
| 24772 | 2010-01-25 14:11:11.155 | pduarte | 0 | 0 | 0 | Software shots - New vertical field power supply tests. |
| 24771 | 2010-01-25 13:54:46.574 | pduarte | 0 | 0 | 0 | Software shots - New vertical field power supply tests. |
| 24770 | 2010-01-25 13:49:52.745 | pduarte | 0 | 0 | 0 | Software shots - New vertical field power supply tests. |
| 24769 | 2010-01-25 13:44:56.86 | pduarte | 0 | 0 | 0 | Software shots - New vertical field power supply tests. |
| 24768 | 2010-01-25 13:39:22.517 | pduarte | 0 | 0 | 0 | Software shots - New vertical field power supply tests. |
| 24767 | 2010-01-25 13:33:50.188 | pduarte | 0 | 0 | 0 | Software shots - New vertical field power supply tests. |
| 24766 | 2010-01-25 12:32:48.294 | pduarte | 0 | 0 | 0 | Software shots - New vertical field power supply tests. |
| 24765 | 2010-01-25 12:28:30.379 | pduarte | 0 | 0 | 0 | Software shots - New vertical field power supply tests. |
| 24764 | 2010-01-22 17:05:17.663 | pduarte | 0 | 0 | 0 | 40 turns primary. R = 0,4ohm. ELCO = 190V. without gas. Pre-Programmed V and H field. photodiode on atcaB1.ch27. e-probes r~65 |
| 24763 | 2010-01-22 16:59:52.887 | pduarte | 4.1 | 2.9 | 30 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,5x10^(-4)mbar. Pre-Programmed V and H field. photodiode on atcaB1.ch27. e-probes r~65 |
| 24762 | 2010-01-22 16:52:49.537 | pduarte | 4.1 | 2.9 | 30 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,5x10^(-4)mbar. Pre-Programmed V and H field. photodiode on atcaB1.ch27. e-probes r~70 |
| 24761 | 2010-01-22 16:46:08.524 | pduarte | 4.2 | 3 | 30 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,5x10^(-4)mbar. Pre-Programmed V and H field. photodiode on atcaB1.ch27. e-probes r~75 |
| 24760 | 2010-01-22 16:39:30.581 | pduarte | 4.4 | 3.1 | 30 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,5x10^(-4)mbar. Pre-Programmed V and H field. photodiode on atcaB1.ch27. e-probes r~75 |
| 24759 | 2010-01-22 16:20:50.09 | pduarte | 4.1 | 3 | 30 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,4x10^(-4)mbar. Pre-Programmed V and H field. photodiode on atcaB1.ch27. e-probes r~86 |
| 24758 | 2010-01-22 16:14:09.748 | pduarte | 3.6 | 2.7 | 30 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,4x10^(-4)mbar. Pre-Programmed V and H field. photodiode on atcaB1.ch27. e-probes r~86 |
| 24757 | 2010-01-22 16:04:02.673 | pduarte | 3.6 | 3 | 30 | 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,2x10^(-4)mbar. Pre-Programmed V and H field. photodiode on atcaB1.ch27. e-probes r~75 |
| 24756 | 2010-01-22 15:29:08.975 | pduarte | 0 | 0 | 0 | Software shots - New vertical field power supply tests. |
| 24755 | 2010-01-22 15:22:43.268 | pduarte | 0 | 0 | 0 | Software shots - New vertical field power supply tests. |
| 24754 | 2010-01-22 15:11:04.498 | pduarte | 0 | 0 | 0 | Software shots - New vertical field power supply tests. |