Session aimSoftware shots - New vertical field power supply tests.
Session day2010-01-22Operatorpduarte
Session IDISTTOK_2010122_1Coordinatorpduarte

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
247752010-01-25 14:52:13.358pduarte000Software shots - New vertical field power supply tests.
247742010-01-25 14:43:45.39pduarte000Software shots - New vertical field power supply tests.
247732010-01-25 14:20:31.038pduarte000Software shots - New vertical field power supply tests.
247722010-01-25 14:11:11.155pduarte000Software shots - New vertical field power supply tests.
247712010-01-25 13:54:46.574pduarte000Software shots - New vertical field power supply tests.
247702010-01-25 13:49:52.745pduarte000Software shots - New vertical field power supply tests.
247692010-01-25 13:44:56.86pduarte000Software shots - New vertical field power supply tests.
247682010-01-25 13:39:22.517pduarte000Software shots - New vertical field power supply tests.
247672010-01-25 13:33:50.188pduarte000Software shots - New vertical field power supply tests.
247662010-01-25 12:32:48.294pduarte000Software shots - New vertical field power supply tests.
247652010-01-25 12:28:30.379pduarte000Software shots - New vertical field power supply tests.
247642010-01-22 17:05:17.663pduarte00040 turns primary. R = 0,4ohm. ELCO = 190V. without gas. Pre-Programmed V and H field. photodiode on atcaB1.ch27. e-probes r~65
247632010-01-22 16:59:52.887pduarte4.12.93040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,5x10^(-4)mbar. Pre-Programmed V and H field. photodiode on atcaB1.ch27. e-probes r~65
247622010-01-22 16:52:49.537pduarte4.12.93040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,5x10^(-4)mbar. Pre-Programmed V and H field. photodiode on atcaB1.ch27. e-probes r~70
247612010-01-22 16:46:08.524pduarte4.233040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,5x10^(-4)mbar. Pre-Programmed V and H field. photodiode on atcaB1.ch27. e-probes r~75
247602010-01-22 16:39:30.581pduarte4.43.13040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,5x10^(-4)mbar. Pre-Programmed V and H field. photodiode on atcaB1.ch27. e-probes r~75
247592010-01-22 16:20:50.09pduarte4.133040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,4x10^(-4)mbar. Pre-Programmed V and H field. photodiode on atcaB1.ch27. e-probes r~86
247582010-01-22 16:14:09.748pduarte3.62.73040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,4x10^(-4)mbar. Pre-Programmed V and H field. photodiode on atcaB1.ch27. e-probes r~86
247572010-01-22 16:04:02.673pduarte3.633040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,2x10^(-4)mbar. Pre-Programmed V and H field. photodiode on atcaB1.ch27. e-probes r~75
247562010-01-22 15:29:08.975pduarte000Software shots - New vertical field power supply tests.
247552010-01-22 15:22:43.268pduarte000Software shots - New vertical field power supply tests.
247542010-01-22 15:11:04.498pduarte000Software shots - New vertical field power supply tests.