Session aimGallium exposition and IR sensor tests
Session day2010-01-07Operatorpduarte
Session IDISTTOK_201017_2Coordinatorpduarte

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
244502010-01-07 17:20:33.824pduarte3.52.93040 turns primary. R = 0,4ohm. ELCO = 180V. P=1,6x10^(-4)mbar. Pre-Programmed V and H field. Ga injector r=60. IR1 & IR2 acquisition on atcaB2.ch14 & ch15. Plasma out
244492010-01-07 17:10:05.622pduarte3.833040 turns primary. R = 0,4ohm. ELCO = 180V. P=1,6x10^(-4)mbar. Pre-Programmed V and H field. Ga injector r=60. IR1 & IR2 acquisition on atcaB2.ch14 & ch15.
244482010-01-07 16:54:19.967pduarte3.733040 turns primary. R = 0,4ohm. ELCO = 180V. P=1,6x10^(-4)mbar. Pre-Programmed V and H field. Ga injector r=60. IR1 & IR2 acquisition on atcaB2.ch14 & ch15.
244472010-01-07 16:28:40.154pduarte3.93.23040 turns primary. R = 0,4ohm. ELCO = 180V. P=1,6x10^(-4)mbar. Pre-Programmed V and H field. Ga injector r=60. IR1 & IR2 acquisition on atcaB2.ch14 & ch15.
244462010-01-07 16:07:59.569pduarte43.23040 turns primary. R = 0,4ohm. ELCO = 180V. P=1,6x10^(-4)mbar. Pre-Programmed V and H field. Ga injector r=66. IR1 & IR2 acquisition on atcaB2.ch14 & ch15.
244452010-01-07 15:56:17.557pduarte43.23040 turns primary. R = 0,4ohm. ELCO = 180V. P=1,6x10^(-4)mbar. Pre-Programmed V and H field. Ga injector r=64. IR1 & IR2 acquisition on atcaB2.ch14 & ch15.
244442010-01-07 15:44:03.211pduarte43.33040 turns primary. R = 0,4ohm. ELCO = 180V. P=1,6x10^(-4)mbar. Pre-Programmed V and H field. Ga injector r=62. IR1 & IR2 acquisition on atcaB2.ch14 & ch15.
244432010-01-07 15:33:29.396pduarte3.93.23040 turns primary. R = 0,4ohm. ELCO = 180V. P=1,6x10^(-4)mbar. Pre-Programmed V and H field. Ga injector r=60. IR1 & IR2 acquisition on atcaB2.ch14 & ch15.
244422010-01-07 15:25:33.736pduarte433040 turns primary. R = 0,4ohm. ELCO = 180V. P=1,6x10^(-4)mbar. Pre-Programmed V and H field. Ga injector r=60. IR1 & IR2 acquisition on atcaB2.ch14 & ch15. without Ga
244412010-01-07 15:10:52.47pduarte3.93.23040 turns primary. R = 0,4ohm. ELCO = 180V. P=1,6x10^(-4)mbar. Pre-Programmed V and H field. Ga injector r=60. IR1 & IR2 acquisition on atcaB2.ch14 & ch15
244402010-01-07 15:04:13.27pduarte433040 turns primary. R = 0,4ohm. ELCO = 180V. P=1,6x10^(-4)mbar. Pre-Programmed V and H field.
244392010-01-07 14:58:43.572pduarte3.933040 turns primary. R = 0,4ohm. ELCO = 180V. P=1,6x10^(-4)mbar. Pre-Programmed V and H field.
244382010-01-07 14:53:16.504pduarte3.42.83040 turns primary. R = 0,4ohm. ELCO = 180V. P=1,6x10^(-4)mbar. Pre-Programmed V and H field.
244372010-01-07 14:45:10.10pduarte000PRECO failures. 40 turns primary. R = 0,4ohm. ELCO = 180V. P=1,6x10^(-4)mbar. Pre-Programmed V and H field.