Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
250752010-02-11 17:22:18.711pduarte000Software shot. Gallium IR sensor callibration
250742010-02-11 17:13:45.537pduarte4.33.53040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed V and H field.
250732010-02-11 17:08:09.552pduarte000ELCO circuit breaker failure
250722010-02-11 17:02:18.773pduarte4.73.53040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed V and H field.
250712010-02-11 16:56:39.037pduarte4.73.53040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed V and H field.
250702010-02-11 16:51:04.998pduarte4.93.23040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed V and H field.
250692010-02-11 16:45:26.762pduarte4.83.53040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed V and H field.
250682010-02-11 16:40:00.919pduarte53.33040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed V and H field.
250672010-02-11 16:34:26.331pduarte4.83.53040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed V and H field.
250662010-02-11 16:28:42.435pduarte53.23040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed V and H field.
250652010-02-11 16:22:58.099pduarte4.83.33040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed V and H field.
250642010-02-11 16:16:14.659pduarte000Software shot. Gallium IR sensor callibration
250632010-02-11 16:11:52.955pduarte000Software shot. Gallium IR sensor callibration
250622010-02-11 16:02:28.575pduarte53.43040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed V and H field.
250612010-02-11 15:56:34.617pduarte53.43040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed V and H field.
250602010-02-11 15:50:19.129pduarte53.33040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed V and H field.
250592010-02-11 15:44:47.389pduarte53.33040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed V and H field.
250582010-02-11 15:39:09.531pduarte53.43040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed V and H field.
250572010-02-11 15:32:21.571pduarte53.53040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed V and H field.
250562010-02-11 15:25:55.374pduarte53.43040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed V and H field.
250552010-02-11 15:18:36.46pduarte53.53040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed V and H field.
250542010-02-11 15:12:30.224pduarte4.93.53040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed V and H field.
250532010-02-11 15:06:56.129pduarte4.93.43040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed V and H field.
250522010-02-11 15:01:07.158pduarte4.73.73040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed V and H field.
250512010-02-11 14:55:01.603pduarte4.23.33040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.
250502010-02-11 14:45:53.739pduarte3.73.23040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.
250492010-02-11 14:39:54.952pduarte2.42.53040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.
250482010-02-11 14:31:26.404pduarte000Software shot. Gallium IR sensor callibration
250472010-02-11 12:31:35.646pduarte000Software shot. Gallium IR sensor callibration