Session aimMachine conditioning. Ga deviation. RFA tests.
Session day2010-02-23Operatorpduarte
Session IDISTTOK_2010223_1Coordinatorpduarte

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
251602010-02-23 17:04:22.161pduarte000ELCO failure
251592010-02-23 16:57:19.21pduarte001ELCO failure. Ga
251582010-02-23 16:50:49.787pduarte3.53.53040 turns primary. R = 0,4ohm. ELCO = 210V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field. Ga
251572010-02-23 16:44:57.485pduarte3.843040 turns primary. R = 0,4ohm. ELCO = 210V. P=1,30x10^(-4)mbar. Pre-Programmed V and H field. Ga
251562010-02-23 16:37:17.323pduarte3.843040 turns primary. R = 0,4ohm. ELCO = 210V. P=1,30x10^(-4)mbar. Pre-Programmed V and H field. Ga
251552010-02-23 16:30:09.149pduarte3.93.93040 turns primary. R = 0,4ohm. ELCO = 210V. P=1,30x10^(-4)mbar. Pre-Programmed V and H field. Ga
251542010-02-23 16:23:20.02pduarte43.63040 turns primary. R = 0,4ohm. ELCO = 210V. P=1,30x10^(-4)mbar. Pre-Programmed V and H field.
251532010-02-23 16:16:52.294pduarte3.73.73040 turns primary. R = 0,4ohm. ELCO = 210V. P=1,30x10^(-4)mbar. Pre-Programmed V and H field. Ga
251522010-02-23 16:08:29.044pduarte3.83.83040 turns primary. R = 0,4ohm. ELCO = 210V. P=1,30x10^(-4)mbar. Pre-Programmed V and H field. Ga
251512010-02-23 16:02:24.522pduarte3.73.73040 turns primary. R = 0,4ohm. ELCO = 210V. P=1,30x10^(-4)mbar. Pre-Programmed V and H field. Ga
251502010-02-23 15:50:51.822pduarte3.73.53040 turns primary. R = 0,4ohm. ELCO = 210V. P=1,30x10^(-4)mbar. Pre-Programmed V and H field. Ga
251492010-02-23 15:45:17.165pduarte3.73.33040 turns primary. R = 0,4ohm. ELCO = 210V. P=1,30x10^(-4)mbar. Pre-Programmed V and H field.
251482010-02-23 15:39:19.106pduarte3.433040 turns primary. R = 0,4ohm. ELCO = 210V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.
251472010-02-23 15:33:29.792pduarte3.12.83040 turns primary. R = 0,4ohm. ELCO = 210V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.
251462010-02-23 15:27:14pduarte2.22.22740 turns primary. R = 0,4ohm. ELCO = 210V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.
251452010-02-23 15:21:24.676pduarte1.92.43040 turns primary. R = 0,4ohm. ELCO = 210V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.
251442010-02-23 15:14:15.713pduarte1.22.53040 turns primary. R = 0,4ohm. ELCO = 210V. P=1,10x10^(-4)mbar. Pre-Programmed V and H field.