Session aimToroidal field inverted. E-probes
Session day2010-02-03Operatorpduarte
Session IDISTTOK_201023_1Coordinatorpduarte

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
249192010-02-03 17:26:13.442pduarte6.33.330Toroidal field inverted. 40 turns primary. R = 0,4ohm. ELCO = 180V. P=1,30x10^(-4)mbar. Pre-Programmed V and H field.
249182010-02-03 17:14:04.171pduarte6.33.430Toroidal field inverted. 40 turns primary. R = 0,4ohm. ELCO = 180V. P=1,30x10^(-4)mbar. Pre-Programmed V and H field.
249172010-02-03 17:05:58.345pduarte6.33.430Toroidal field inverted. 40 turns primary. R = 0,4ohm. ELCO = 180V. P=1,00x10^(-4)mbar. Pre-Programmed V and H field.
249162010-02-03 16:59:48.44pduarte5.53.630Toroidal field inverted. 40 turns primary. R = 0,4ohm. ELCO = 180V. P=1,00x10^(-4)mbar. Pre-Programmed V and H field.
249152010-02-03 16:52:16.321pduarte002Toroidal field inverted. 40 turns primary. R = 0,4ohm. ELCO = 180V. P=1,50x10^(-4)mbar. Pre-Programmed V and H field.
249142010-02-03 16:25:11.838pduarte003Toroidal field inverted. 40 turns primary. R = 0,4ohm. ELCO = 180V. P=1,70x10^(-4)mbar. Pre-Programmed V and H field.
249132010-02-03 16:17:05.145pduarte6.43.330Toroidal field inverted. 40 turns primary. R = 0,4ohm. ELCO = 180V. P=1,40x10^(-4)mbar. Pre-Programmed V and H field.
249122010-02-03 16:07:58.124pduarte6.63.130Toroidal field inverted. 40 turns primary. R = 0,4ohm. ELCO = 180V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.
249112010-02-03 16:01:52.408pduarte6.43.230Toroidal field inverted. 40 turns primary. R = 0,4ohm. ELCO = 180V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.
249102010-02-03 15:54:05.743pduarte6.23.630Toroidal field inverted. 40 turns primary. R = 0,4ohm. ELCO = 180V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.
249092010-02-03 15:47:16.867pduarte002IHORIZ failure. Toroidal field inverted. 40 turns primary. R = 0,4ohm. ELCO = 180V. P=1,20x10^(-4)mbar. Pre-Programmed V field.
249082010-02-03 15:40:53.313pduarte6.63.230Toroidal field inverted. 40 turns primary. R = 0,4ohm. ELCO = 180V. P=1,00x10^(-4)mbar. Pre-Programmed V and H field.
249072010-02-03 15:35:00.798pduarte6.23.430Toroidal field inverted. 40 turns primary. R = 0,4ohm. ELCO = 180V. P=1,00x10^(-4)mbar. Pre-Programmed V and H field.
249062010-02-03 15:27:52.307pduarte001ELCO circuit breaker failure
249052010-02-03 15:18:26.006pduarte6.33.530Toroidal field inverted. 40 turns primary. R = 0,4ohm. ELCO = 180V. P=1,00x10^(-4)mbar. Pre-Programmed V and H field.
249042010-02-03 14:52:35.738pduarte6.33.530Toroidal field inverted. 40 turns primary. R = 0,4ohm. ELCO = 180V. P=1,00x10^(-4)mbar. Pre-Programmed V and H field.
249032010-02-03 14:37:29.212pduarte5.73.430Toroidal field inverted. 40 turns primary. R = 0,4ohm. ELCO = 180V. P=1,00x10^(-4)mbar. Pre-Programmed V and H field.
249022010-02-03 14:31:33.881pduarte4.93.730Toroidal field inverted. 40 turns primary. R = 0,4ohm. ELCO = 180V. P=1,00x10^(-4)mbar. Pre-Programmed V and H field.
249012010-02-03 14:24:42.273pduarte3.72.530Toroidal field inverted. 40 turns primary. R = 0,4ohm. ELCO = 180V. P=0,90x10^(-4)mbar. Pre-Programmed V and H field.