Session aimToroidal field inverted. E-probes
Session day2010-02-04Operatorpduarte
Session IDISTTOK_201024_2Coordinatorpduarte

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
249522010-02-04 17:17:00.046pduarte001ELCO failure. TACSP failure in previous shot.
249512010-02-04 17:07:24.625pduarte5.5332TACSP failure. Toroidal field inverted. 40 turns primary. R = 0,4ohm. ELCO = 170V. P=1,10x10^(-4)mbar. Pre-Programmed V and H field.
249502010-02-04 17:01:48.789pduarte5330Toroidal field inverted. 40 turns primary. R = 0,4ohm. ELCO = 170V. P=1,10x10^(-4)mbar. Pre-Programmed V and H field. plasma up
249492010-02-04 16:56:24.311pduarte6.12.930Toroidal field inverted. 40 turns primary. R = 0,4ohm. ELCO = 170V. P=1,10x10^(-4)mbar. Pre-Programmed V and H field.
249482010-02-04 16:49:26.509pduarte6.22.930Toroidal field inverted. 40 turns primary. R = 0,4ohm. ELCO = 170V. P=1,10x10^(-4)mbar. Pre-Programmed V and H field.
249472010-02-04 16:43:21.317pduarte6.1330Toroidal field inverted. 40 turns primary. R = 0,4ohm. ELCO = 170V. P=1,10x10^(-4)mbar. Pre-Programmed V and H field.
249462010-02-04 16:37:52.189pduarte63.530Toroidal field inverted. 40 turns primary. R = 0,4ohm. ELCO = 170V. P=1,10x10^(-4)mbar. Pre-Programmed V and H field.
249452010-02-04 16:31:49.134pduarte001ELCO circuit breaker failure
249442010-02-04 16:25:54.845pduarte6.2330Toroidal field inverted. 40 turns primary. R = 0,4ohm. ELCO = 170V. P=1,10x10^(-4)mbar. Pre-Programmed V and H field.
249432010-02-04 16:19:36.887pduarte6.1330Toroidal field inverted. 40 turns primary. R = 0,4ohm. ELCO = 170V. P=1,10x10^(-4)mbar. Pre-Programmed V and H field.
249422010-02-04 16:12:39.459pduarte6.3330Toroidal field inverted. 40 turns primary. R = 0,4ohm. ELCO = 170V. P=1,10x10^(-4)mbar. Pre-Programmed V and H field.
249412010-02-04 16:07:11.971pduarte6.2330Toroidal field inverted. 40 turns primary. R = 0,4ohm. ELCO = 170V. P=1,10x10^(-4)mbar. Pre-Programmed V and H field.
249402010-02-04 16:00:18.018pduarte6.2330Toroidal field inverted. 40 turns primary. R = 0,4ohm. ELCO = 170V. P=1,00x10^(-4)mbar. Pre-Programmed V and H field.
249392010-02-04 15:52:09.912pduarte6.13.130Toroidal field inverted. 40 turns primary. R = 0,4ohm. ELCO = 170V. P=1,00x10^(-4)mbar. Pre-Programmed V and H field.
249382010-02-04 15:34:03.601pduarte6.23.130Toroidal field inverted. 40 turns primary. R = 0,4ohm. ELCO = 170V. P=1,00x10^(-4)mbar. Pre-Programmed V and H field.
249372010-02-04 15:11:19.858pduarte6.23.230Toroidal field inverted. 40 turns primary. R = 0,4ohm. ELCO = 170V. P=1,00x10^(-4)mbar. Pre-Programmed V and H field.
249362010-02-04 15:04:45.153pduarte001ELCO circuit breaker failure
249352010-02-04 14:57:46.771pduarte6.32.730Toroidal field inverted. 40 turns primary. R = 0,4ohm. ELCO = 170V. P=1,00x10^(-4)mbar. Pre-Programmed V and H field.
249342010-02-04 14:51:35.907pduarte6.32.930Toroidal field inverted. 40 turns primary. R = 0,4ohm. ELCO = 170V. P=1,00x10^(-4)mbar. Pre-Programmed V and H field.
249332010-02-04 14:43:46.003pduarte6.32.830Toroidal field inverted. 40 turns primary. R = 0,4ohm. ELCO = 170V. P=1,00x10^(-4)mbar. Pre-Programmed V and H field.
249322010-02-04 14:38:13.429pduarte6.3330Toroidal field inverted. 40 turns primary. R = 0,4ohm. ELCO = 170V. P=1,00x10^(-4)mbar. Pre-Programmed V and H field.
249312010-02-04 14:29:06.789pduarte6.23.130Toroidal field inverted. 40 turns primary. R = 0,4ohm. ELCO = 170V. P=1,00x10^(-4)mbar. Pre-Programmed V and H field.
249302010-02-04 14:22:18.699pduarte63.830Toroidal field inverted. 40 turns primary. R = 0,4ohm. ELCO = 170V. P=1,00x10^(-4)mbar. Pre-Programmed V and H field.
249292010-02-04 14:11:24.32pduarte63.530Toroidal field inverted. 40 turns primary. R = 0,4ohm. ELCO = 170V. P=1,00x10^(-4)mbar. Pre-Programmed V and H field.
249282010-02-04 14:04:59.939pduarte5.63.130Toroidal field inverted. 40 turns primary. R = 0,4ohm. ELCO = 170V. P=1,00x10^(-4)mbar. Pre-Programmed V and H field.
249272010-02-04 13:56:29.925pduarte5.63.730Toroidal field inverted. 40 turns primary. R = 0,4ohm. ELCO = 180V. P=1,00x10^(-4)mbar. Pre-Programmed V and H field.
249262010-02-04 13:49:07.943pduarte53.430Toroidal field inverted. 40 turns primary. R = 0,4ohm. ELCO = 180V. P=0,90x10^(-4)mbar. Pre-Programmed V and H field.