Session aimGa jet deviation, IR temperatura sensor
Session day2010-02-09Operatorpduarte
Session IDISTTOK_201029_1Coordinatorpduarte

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
250212010-02-09 17:05:46.564pduarte3.43.33040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed V and H field. IR on atcaB2.ch14-15. Ga injector=60. plasma out
250202010-02-09 16:59:33.006pduarte3.43.23040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed V and H field. IR on atcaB2.ch14-15. Ga injector=60. plasma out
250192010-02-09 16:50:49.077pduarte3.63.53040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed V and H field. IR on atcaB2.ch14-15. Ga injector=60.
250182010-02-09 16:29:21.787pduarte3.53.53040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed V and H field. IR on atcaB2.ch14-15. Ga injector=60.
250172010-02-09 16:20:10.624pduarte3.93.63040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed V and H field. IR on atcaB2.ch14-15. Ga injector=60.
250162010-02-09 16:11:06.658pduarte3.93.83040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed V and H field. IR on atcaB2.ch14-15. Ga injector=60.
250152010-02-09 16:00:02.65pduarte43.93040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed V and H field. IR on atcaB2.ch14-15. Ga injector=60.
250142010-02-09 15:51:22.648pduarte3.93.93040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed V and H field. IR on atcaB2.ch14-15. Ga injector=60.
250132010-02-09 15:41:20.222pduarte3.83.53040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed V and H field. IR on atcaB2.ch14-15. Ga injector=60.
250122010-02-09 15:35:30.625pduarte001ELCO circuit breaker failure
250112010-02-09 15:29:36.398pduarte4.54.33040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed V and H field. IR on atcaB2.ch14-15. Ga injector=60.
250102010-02-09 15:24:07.476pduarte4.64.13040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed V and H field.
250092010-02-09 15:18:11.65pduarte4.84.33040 turns primary. R = 0,4ohm. ELCO = 200V. P=1,40x10^(-4)mbar. Pre-Programmed V and H field.
250082010-02-09 15:11:49.493pduarte4.64.53040 turns primary. R = 0,4ohm. ELCO = 200V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.
250072010-02-09 15:06:23.539pduarte4.23.63040 turns primary. R = 0,4ohm. ELCO = 200V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.
250062010-02-09 15:00:54.154pduarte3.73.43040 turns primary. R = 0,4ohm. ELCO = 200V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.
250052010-02-09 14:54:41.439pduarte2.82.53040 turns primary. R = 0,4ohm. ELCO = 200V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.
250042010-02-09 14:48:39.294pduarte2.52.63040 turns primary. R = 0,4ohm. ELCO = 200V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.
250032010-02-09 14:43:02.208pduarte1.32.33040 turns primary. R = 0,4ohm. ELCO = 200V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.
250022010-02-09 14:33:22.168pduarte00240 turns primary. R = 0,4ohm. ELCO = 180V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.