Session aimPrimary and Toroidal field Inverted. E-Probes
Session day2010-03-16Operatorpduarte
Session IDISTTOK_2010316_1Coordinatorpduarte

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
254942010-03-16 17:46:50.651pduarte5.54.530Primary and Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 190V. P=0,90x10^(-4)mbar. Pre-Programmed V and H field. e-probes=70, e-probes on atcaB1.ch29,31
254932010-03-16 17:40:22.411pduarte-5.34.330Primary and Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 190V. P=0,90x10^(-4)mbar. Pre-Programmed V and H field. e-probes=70, e-probes on atcaB1.ch29,31
254922010-03-16 17:34:33.619pduarte000ELCO circuit breaker failure
254912010-03-16 17:28:11.645pduarte5.84.530Primary and Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 190V. P=0,90x10^(-4)mbar. Pre-Programmed V and H field. PD on atcaB2.ch16, e-probes=70, e-probes on atcaB1.ch29,31
254902010-03-16 17:22:32.328pduarte5.74.530Primary and Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 190V. P=0,90x10^(-4)mbar. Pre-Programmed V and H field. PD on atcaB2.ch16, e-probes=70, e-probes on atcaB1.ch29,31
254892010-03-16 17:14:06.263pduarte5.34.530Primary and Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 190V. P=0,90x10^(-4)mbar. Pre-Programmed V and H field. PD on atcaB2.ch16, e-probes=70, e-probes on atcaB1.ch29,31
254882010-03-16 17:07:44.662pduarte001ELCO circuit breaker failure
254862010-03-16 16:47:50.187pduarte5.84.630Primary and Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 190V. P=0,90x10^(-4)mbar. Pre-Programmed V and H field. PD on atcaB2.ch16, e-probes=70, e-probes on atcaB1.ch29,31
254852010-03-16 16:39:04.287pduarte5.74.530Primary and Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 190V. P=0,90x10^(-4)mbar. Pre-Programmed V and H field. PD on atcaB2.ch16, e-probes=70, e-probes on atcaB1.ch29,31
254842010-03-16 16:32:22.616pduarte5.44.730Primary and Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 190V. P=0,90x10^(-4)mbar. Pre-Programmed V and H field. PD on atcaB2.ch16, e-probes=70, e-probes on atcaB1.ch29
254832010-03-16 16:12:49.738pduarte001Primary and Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 190V. P=0,90x10^(-4)mbar. Pre-Programmed V and H field.
254822010-03-16 16:04:42.819pduarte5.74.730Primary and Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 190V. P=0,90x10^(-4)mbar. Pre-Programmed V and H field.
254812010-03-16 15:57:30.92pduarte5.5430Primary and Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 190V. P=0,90x10^(-4)mbar. Pre-Programmed V and H field.
254802010-03-16 15:42:59.016pduarte-5.5430Primary and Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 190V. P=0,90x10^(-4)mbar. Pre-Programmed V and H field.
254792010-03-16 15:24:08.409pduarte53.630Primary and Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 190V. P=0,90x10^(-4)mbar. Pre-Programmed V and H field.
254782010-03-16 15:12:29.078pduarte4.5330Primary and Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 190V. P=0,90x10^(-4)mbar. Pre-Programmed V and H field.
254772010-03-16 14:59:53.242pduarte42.630Primary and Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 190V. P=0,90x10^(-4)mbar. Pre-Programmed V and H field.
254762010-03-16 14:54:05.449pduarte004Primary and Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=0,90x10^(-4)mbar. Pre-Programmed V and H field.
254752010-03-16 14:44:00.032pduarte004Primary and Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=1,00x10^(-4)mbar. Pre-Programmed V and H field.
254742010-03-16 14:21:49.17pduarte001ELCO circuit breaker failure
254732010-03-16 14:15:00.987pduarte-31.511IVERT failure. Primary and Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=1,00x10^(-4)mbar. Pre-Programmed V and H field.
254722010-03-16 12:31:20.033pduarte001ELCO circuit breaker failure
254712010-03-16 12:25:52.994pduarte7.33.930Primary and Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=1,00x10^(-4)mbar. Pre-Programmed V and H field.
254702010-03-16 12:20:21.004pduarte-73.930Primary and Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=1,00x10^(-4)mbar. Pre-Programmed V and H field.
254692010-03-16 12:14:55.667pduarte6.9430Primary and Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=1,00x10^(-4)mbar. Pre-Programmed V and H field.
254682010-03-16 12:08:49.723pduarte6.74.330Primary and Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=0,90x10^(-4)mbar. Pre-Programmed V and H field.
254672010-03-16 12:03:15.069pduarte001ELCO circuit breaker failure
254662010-03-16 11:56:06.012pduarte-7430Primary and Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=0,90x10^(-4)mbar. Pre-Programmed V and H field.
254652010-03-16 11:50:20.333pduarte-6.6430Primary and Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=0,90x10^(-4)mbar. Pre-Programmed V and H field.
254642010-03-16 11:42:33.871pduarte-6430Primary and Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=0,90x10^(-4)mbar. Pre-Programmed V and H field.
254632010-03-16 11:36:20.155pduarte-5.44.630Primary and Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=0,90x10^(-4)mbar. Pre-Programmed V and H field.
254622010-03-16 11:30:12.399pduarte-4.94.830Primary and Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=0,90x10^(-4)mbar. Pre-Programmed V and H field.
254612010-03-16 11:24:13.222pduarte-4330Primary and Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=0,90x10^(-4)mbar. Pre-Programmed V and H field.
254602010-03-16 11:05:46.437pduarte-3.52.730Primary and Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=0,90x10^(-4)mbar. Pre-Programmed V and H field.