Session aimRFA tests. Ga deviation.
Session day2010-03-22Operatorpduarte
Session IDISTTOK_2010322_1Coordinatorpduarte

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
255872010-03-22 15:28:16.858pduarte11.73040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.
255862010-03-22 15:22:48.354pduarte11.73040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.
255852010-03-22 15:17:22.966pduarte11.83040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.
255842010-03-22 15:08:14.579pduarte11.73040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.
255832010-03-22 14:59:01.056pduarte0.923040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.
255822010-03-22 14:52:36.536pduarte0.823040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.
255812010-03-22 14:46:57.04pduarte00840 turns primary. R = 0,4ohm. ELCO = 190V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.
255802010-03-22 14:41:20.963pduarte11.73040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.
255792010-03-22 14:35:39.217pduarte11.72040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.
255782010-03-22 14:29:41.325pduarte123040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.
255772010-03-22 14:24:05.048pduarte123040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.
255762010-03-22 14:12:33.258pduarte0.621540 turns primary. R = 0,4ohm. ELCO = 190V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.
255752010-03-22 14:06:12.892pduarte00540 turns primary. R = 0,4ohm. ELCO = 190V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.
255742010-03-22 14:00:41.814pduarte001ELCO circuit breaker failure.