Session aimMachine conditioning. RFA tests. Ga deviation.
Session day2010-03-23Operatorpduarte
Session IDISTTOK_2010323_1Coordinatorpduarte

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
256162010-03-23 16:51:40.866pduarte43.53040 turns primary. R = 0,4ohm. ELCO = 200V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.
256152010-03-23 16:45:35.811pduarte43.53040 turns primary. R = 0,4ohm. ELCO = 200V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.
256142010-03-23 16:39:16.202pduarte43.63040 turns primary. R = 0,4ohm. ELCO = 200V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.
256132010-03-23 16:33:04.54pduarte43.63040 turns primary. R = 0,4ohm. ELCO = 200V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.
256122010-03-23 16:26:35.424pduarte43.63040 turns primary. R = 0,4ohm. ELCO = 200V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.
256112010-03-23 16:20:50.911pduarte43.63040 turns primary. R = 0,4ohm. ELCO = 200V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.
256102010-03-23 16:14:57.226pduarte3.93.53040 turns primary. R = 0,4ohm. ELCO = 200V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.
256092010-03-23 16:07:31.058pduarte3.93.73040 turns primary. R = 0,4ohm. ELCO = 200V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.
256082010-03-23 16:01:43.72pduarte3.73.23040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.
256072010-03-23 15:55:15.846pduarte3.53.13040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.
256062010-03-23 15:49:04.418pduarte001ELCO circuit breaker failure
256052010-03-23 15:43:34.153pduarte3.93.33040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.
256042010-03-23 15:37:48.347pduarte3.93.33040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.
256032010-03-23 15:32:12.463pduarte3.93.43040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.
256022010-03-23 15:26:00.798pduarte3.93.53040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.
256012010-03-23 15:20:30.531pduarte3.93.23040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.
256002010-03-23 15:14:31.91pduarte3.93.33040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.
255992010-03-23 15:08:38.936pduarte3.73.33040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.
255982010-03-23 15:02:24.455pduarte3.633040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.
255972010-03-23 14:55:33.941pduarte3.33.13040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.
255962010-03-23 14:49:42.776pduarte001ELCO circuit breaker failure
255952010-03-23 14:43:24.503pduarte3.733040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.
255942010-03-23 14:36:40.349pduarte3.533040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.
255932010-03-23 14:31:06.461pduarte3.12.63040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,10x10^(-4)mbar. Pre-Programmed V and H field.
255922010-03-23 14:25:11.571pduarte2.82.230Primary and Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,10x10^(-4)mbar. Pre-Programmed V and H field.
255912010-03-23 14:18:47.925pduarte2.72.13040 turns primary. R = 0,4ohm. ELCO = 190V. P=1,10x10^(-4)mbar. Pre-Programmed V and H field.
255902010-03-23 14:12:49.942pduarte000PRECO failure
255892010-03-23 14:06:44.916pduarte21.72840 turns primary. R = 0,4ohm. ELCO = 190V. P=1,10x10^(-4)mbar. Pre-Programmed V and H field.
255882010-03-23 13:58:36.042pduarte1.522240 turns primary. R = 0,4ohm. ELCO = 190V. P=1,10x10^(-4)mbar. Pre-Programmed V and H field.