Session aimE-probes
Session day2010-04-06Operatorpduarte
Session IDISTTOK_201046_1Coordinatorpduarte

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
258002010-04-06 15:51:51.191pduarte-3.52.930Inverted Primary. 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.
257992010-04-06 15:45:53.703pduarte-2.8230Inverted Primary. 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.
257982010-04-06 15:36:06.216pduarte-21.628Inverted Primary. 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.
257972010-04-06 15:24:12.788pduarte002Inverted Primary. 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.
257962010-04-06 15:17:24.436pduarte002Inverted Primary. 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.
257952010-04-06 15:09:55.102pduarte002Inverted Primary. 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.
257942010-04-06 15:03:11.64pduarte001ELCO circuit breaker failure. Inverted Primary. 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.
257932010-04-06 14:36:19.673pduarte000PRECO failure, MARTe acquisition failure. Inverted Primary. 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.
257922010-04-06 14:19:45.499pduarte001MARTe failure. Inverted Primary. 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.
257912010-04-06 14:14:02.431pduarte001MARTe failure. Inverted Primary. 40 turns primary. R = 0,4ohm. ELCO = 190V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field.