Session aimMachine conditioning. E-probes tests
Session day2011-03-22Operatorpduarte
Session IDISTTOK_2011322_1Coordinatorpduarte

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
288682011-03-22 17:16:29.525pduarte3.63.33240 turns primary. R = 0,4ohm. ELCO = 220V. P=1,40x10^(-4)mbar. E-probe m-par=65. GUND=60.
288672011-03-22 17:09:22.238pduarte3.73.33240 turns primary. R = 0,4ohm. ELCO = 220V. P=1,40x10^(-4)mbar. E-probe m-par=65. GUND=60.
288662011-03-22 17:02:13.216pduarte3.63.33240 turns primary. R = 0,4ohm. ELCO = 220V. P=1,40x10^(-4)mbar. E-probe m-par=65. GUND=60.
288652011-03-22 16:56:19.01pduarte3.63.43240 turns primary. R = 0,4ohm. ELCO = 220V. P=1,40x10^(-4)mbar. E-probe m-par=65. GUND=60.
288642011-03-22 16:49:00.422pduarte3.53.43240 turns primary. R = 0,4ohm. ELCO = 220V. P=1,40x10^(-4)mbar. E-probe m-par=65. GUND=60.
288632011-03-22 16:42:21.655pduarte2.5210MARTe failure. 40 turns primary. R = 0,4ohm. ELCO = 220V. P=1,40x10^(-4)mbar. E-probe m-par=65. GUND=60.
288622011-03-22 16:33:50.544pduarte3.73.43240 turns primary. R = 0,4ohm. ELCO = 220V. P=1,40x10^(-4)mbar. E-probe m-par=65. GUND=65.
288612011-03-22 16:25:22.462pduarte3.32.83240 turns primary. R = 0,4ohm. ELCO = 220V. P=1,40x10^(-4)mbar. E-probe m-par=65. GUND=65.
288602011-03-22 16:10:53.752pduarte3.83.63240 turns primary. R = 0,4ohm. ELCO = 220V. P=1,40x10^(-4)mbar. E-probe m-par=65. GUND=65.
288592011-03-22 16:02:24.301pduarte3.83.43240 turns primary. R = 0,4ohm. ELCO = 220V. P=1,40x10^(-4)mbar. E-probe m-par=70. GUND=70.
288582011-03-22 15:54:40.352pduarte3.73.53240 turns primary. R = 0,4ohm. ELCO = 220V. P=1,40x10^(-4)mbar. E-probe m-par=70. GUND=70.
288572011-03-22 15:48:05.355pduarte3.83.33240 turns primary. R = 0,4ohm. ELCO = 220V. P=1,40x10^(-4)mbar. E-probe m-par=75.
288562011-03-22 15:39:42.846pduarte3.73.13240 turns primary. R = 0,4ohm. ELCO = 220V. P=1,40x10^(-4)mbar. E-probe m-par=75.
288552011-03-22 15:32:25.952pduarte3.53.23240 turns primary. R = 0,4ohm. ELCO = 220V. P=1,40x10^(-4)mbar. E-probe m-par=75.
288542011-03-22 15:25:34.616pduarte3.13.13240 turns primary. R = 0,4ohm. ELCO = 220V. P=1,40x10^(-4)mbar. E-probe m-par=75.
288532011-03-22 15:19:39.133pduarte002MARTe failure. 40 turns primary. R = 0,4ohm. ELCO = 220V. P=1,40x10^(-4)mbar. E-probe m-par=75.
288522011-03-22 15:11:47.222pduarte3.23.13240 turns primary. R = 0,4ohm. ELCO = 220V. P=1,40x10^(-4)mbar. E-probe m-par=85.
288512011-03-22 15:01:46.629pduarte3.13.13240 turns primary. R = 0,4ohm. ELCO = 220V. P=1,40x10^(-4)mbar.
288502011-03-22 14:56:03.892pduarte2.32.63240 turns primary. R = 0,4ohm. ELCO = 220V. P=1,40x10^(-4)mbar.
288492011-03-22 14:43:59.276pduarte22.43240 turns primary. R = 0,4ohm. ELCO = 220V. P=1,20x10^(-4)mbar.