|
Shot
|
Time
|
Operator
|
Iplasma(kA)
|
n(1018m-3)
|
Duration (ms)
|
Pre/post shot comments
|
| 40200 | 2016-06-27 17:59:22.265 | rhenriques | 4.5 | 4 | 75 | EB two pulses before inversion, (ms) Tstart1=1 to Tstop1=2.5, Tstart2=23.5 to Tstop2=25 / cycles:1,3,5 |
| 40199 | 2016-06-27 17:49:05.341 | rhenriques | 4.5 | 4 | 75 | repeat previous / cycles: 1,3,5; density OK |
| 40198 | 2016-06-27 17:40:31.212 | rhenriques | 0 | 0 | 0 | repeat previous / ERROR: GetData: h(=0) different from MARTe h(=-5586944) |
| 40197 | 2016-06-27 17:34:37.928 | rhenriques | 4.5 | 0 | 75 | EB(ms) Tstart=23.5, Tstop=25.5 / cycles: 1,3,5; No density |
| 40196 | 2016-06-27 17:22:41.177 | rhenriques | 4.5 | 4 | 75 | decreasing inversion to 0ms / cycles:1,3,5 |
| 40195 | 2016-06-27 17:03:50.676 | rhenriques | 4.5 | 4 | 75 | decreasing inversion to 0.1ms / cycles:1,3.5 |
| 40194 | 2016-06-27 16:24:06.153 | rhenriques | 4.5 | 4 | 75 | decreasing inversion to 0.2ms; EB(ms) Tstart=23.5, Tstop=25; / cycles:1,3.5 |
| 40193 | 2016-06-27 15:47:36.006 | rhenriques | 4.5 | 4 | 75 | change inversion function to quicker inversions (0.5ms) / cycles:1,4,6 |
| 40192 | 2016-06-27 15:20:09.398 | rhenriques | 4.5 | 4 | 75 | repeat previous because no density signal; EB(ms) Tstart=23, Tstop=24.5; / cycles:1,3,5 |
| 40191 | 2016-06-27 15:11:22.11 | rhenriques | 4.5 | 0 | 75 | EB with V=+120V / cycles: 1,4,6 |
| 40190 | 2016-06-27 14:51:52.013 | rhenriques | 4.5 | 4 | 75 | EB @r=65mm / stil not so big effect from EB; increase EB voltage |
| 40189 | 2016-06-27 14:40:45.456 | rhenriques | 4.5 | 4 | 75 | rake, 2D, EB and HIBD (all) ON with same parameters as when shot # 40185 / cycles: 1,3,6 |
| 40188 | 2016-06-27 14:28:29.911 | rhenriques | 4.5 | 4.5 | 75 | repeat 40186 / cycles:1,4,6 |
| 40187 | 2016-06-27 14:23:05.258 | rhenriques | 0 | 0 | 0 | repeat previous / forgot to start RTscript |
| 40186 | 2016-06-27 14:15:41.455 | rhenriques | 4.5 | 5 | 50 | first shot after glow discharges; all previous diagnostics OFF / only 2 cycles |
| 40185 | 2016-06-27 11:12:53.44 | rhenriques | 4.5 | 4.75 | 75 | repeat previous; HIBD(ON) / HIBD data OK; going to glow discharges |
| 40184 | 2016-06-27 10:58:40.572 | rhenriques | 4.5 | 4.8 | 75 | same as previous with EB(ON) +80V 1ms pulse at 23.5ms; / EB OK; only positive cycles |
| 40183 | 2016-06-27 10:26:39.828 | rhenriques | 4.5 | 5 | 75 | repeat previous; 6 semi-cycles only (due to probes inside plasma); apparently cfg from # 40048 was not loaded, now it is / only positive cycles |
| 40182 | 2016-06-27 10:12:39.218 | rhenriques | 4 | 4 | 100 | starting experiments; rake probe @65mm (B1.ch32,31,30,29,27,26,25,16,15); 2D @85mm (3Vf+1Isat for turbulent transport: B1.ch14,12,11 + B1.ch13); EB(OFF) @70mm / |
| 40181 | 2016-06-27 09:46:49.945 | rhenriques | 4 | 4 | 100 | repeat previous; / same as previous, too much gas when puffing (~1300); |
| 40180 | 2016-06-27 09:39:46.28 | rhenriques | 4 | 4 | 100 | repeat previous / not good yet |
| 40179 | 2016-06-27 09:33:02.501 | rhenriques | 3.75 | 4 | 100 | conditioning discharge; same config as shot # 40048; 10 semi-cycles / |