| Session aim | Study effect of polarization just before current inversion | | Session day | 2016-06-29 | Operator | rhenriques | | Session ID | ISTTOK_2016629_1 | Coordinator | rhenriques |
|
Shot
|
Time
|
Operator
|
Iplasma(kA)
|
n(1018m-3)
|
Duration (ms)
|
Pre/post shot comments
|
| 40246 | 2016-06-29 14:37:54.472 | rhenriques | 4 | 3.75 | 75 | EB ON / cycles: 1,4,6 | | 40245 | 2016-06-29 14:32:29.629 | rhenriques | 4 | 3.9 | 75 | Ip = 4kA; EB OFF / cycles: 1,3,5 | | 40244 | 2016-06-29 14:12:15.722 | rhenriques | 4.5 | 4.6 | 125 | repeat previous / cycles: 1,3,5,7,9 | | 40243 | 2016-06-29 13:39:39.225 | rhenriques | 4.5 | 4.75 | 75 | EB ON, V=+175V / cycles: 1,4,6; FRAEP stopped earlier than usual (during discharge) | | 40242 | 2016-06-29 13:25:30.573 | rhenriques | 4.5 | 4.6 | 125 | repeat previous (HIBD beam OFF) / cycles: 1,3,5,7,9 | | 40241 | 2016-06-29 13:20:06.062 | rhenriques | 4.5 | 4.5 | 125 | EB OFF / cycles: 1,3,5,7,9 | | 40240 | 2016-06-29 13:12:27.584 | rhenriques | 4.5 | 4.6 | 125 | EB ON, V=+200V / cycles: 1,3,5,7,9 | | 40239 | 2016-06-29 12:58:52.792 | rhenriques | 4.5 | 5 | 125 | EB ON, V=+175V / cycles: 1,2,4,6,8 | | 40238 | 2016-06-29 12:52:07.989 | rhenriques | 4.5 | 5 | 125 | repeat previous / cycles: 1,2,4,6,8 | | 40237 | 2016-06-29 11:36:03.175 | rhenriques | 4.5 | 4.5 | 100 | EB ON, V=+150V, Ton=[23.5 to 25]ms / cycles: 1,4,7,9 | | 40236 | 2016-06-29 11:29:59.417 | rhenriques | 4.5 | 4.5 | 125 | repeat previous; reference shot; EB OFF / cycles: | | 40235 | 2016-06-29 11:24:36.721 | rhenriques | 0 | 0 | 0 | repeat previous; 10 semi-cycles / GetData: h(=0) different from master h (=-5619712) | | 40234 | 2016-06-29 11:19:00.314 | rhenriques | 4.5 | 4.5 | 75 | EB OFF; reference shot / cycles: 1,3,5 | | 40233 | 2016-06-29 11:10:32.073 | rhenriques | 4.5 | 4.5 | 75 | EB ON / cycles:1,3,5; OK | | 40232 | 2016-06-29 11:03:51.534 | rhenriques | 4.5 | 4.6 | 75 | EB OFF; HIBD ON; reference shot / cycles: 1,3,5; OK | | 40231 | 2016-06-29 10:47:07.434 | rhenriques | 4.5 | 4.7 | 75 | repeat previous with corrections / cycles: 1,3,5; HIBD modulation was OFF in all previous shots (trigger amplitude was too low for switching) | | 40230 | 2016-06-29 10:41:47.563 | rhenriques | 4.5 | 4.5 | 75 | repeat 40228 because 50Hz modulation on HIBD was ON / cycles: 1,3,5; HIBD amplifiers were OFF | | 40229 | 2016-06-29 10:36:08.405 | rhenriques | 4.5 | 4.6 | 75 | EB ON, HIBD ON, E=23.5keV, Vx=235V, Vy=493V, fmod=180kHz / | | 40228 | 2016-06-29 10:27:39.319 | rhenriques | 4.5 | 4.6 | 75 | repeat previous with corrections / cycles: 1,3,5 | | 40227 | 2016-06-29 10:21:15.277 | rhenriques | 4.5 | 4.6 | 25 | EB OFF for reference / cycles: 2; HIBD was OFF; EB was ON | | 40226 | 2016-06-29 10:10:40.795 | rhenriques | 4.5 | 4.5 | 75 | EB ON, V=-150V / cycles: 1,3,5 | | 40225 | 2016-06-29 09:57:55.686 | rhenriques | 4.5 | 4.75 | 50 | rake @ r=65mm; EB ON, V=-100V / cycles: 2,6 | | 40224 | 2016-06-29 09:50:09.268 | rhenriques | 4.5 | 4.75 | 75 | EB ON, V=-50V / cycles: 1,3,5 | | 40223 | 2016-06-29 09:43:04.929 | rhenriques | 4.5 | 5 | 75 | EB ON, V=-20V / cycles: 2,4,6 | | 40222 | 2016-06-29 09:25:53.411 | rhenriques | 4.5 | 4.8 | 75 | conditioning; EB ON, V=+100V, Ton=[18.5 to 19.5]ms / cycles: 1,3,5 | | 40221 | 2016-06-29 09:20:01.193 | rhenriques | 4.5 | 5 | 75 | conditioning; rake probe (Vf) @r=60mm (B1.ch32,31,30,29,27,26,25,16,15); 2D @85mm (3Vf+1Isat for turbulent transport: B1.ch14,12,11 + B1.ch13); EB(OFF) @r=70mm; HIBD(OFF) / cycles: 1,3,6 | | 40220 | 2016-06-29 09:05:50.723 | rhenriques | 4.5 | 4.5 | 75 | conditioning discharge (repeat of 40219 without diagnostics inside) / cycles: 1,3,5; everything OK |
|