Session aimStudy effect of polarization just before current inversion
Session day2016-06-29Operatorrhenriques
Session IDISTTOK_2016629_1Coordinatorrhenriques

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
402462016-06-29 14:37:54.472rhenriques43.7575EB ON / cycles: 1,4,6
402452016-06-29 14:32:29.629rhenriques43.975Ip = 4kA; EB OFF / cycles: 1,3,5
402442016-06-29 14:12:15.722rhenriques4.54.6125repeat previous / cycles: 1,3,5,7,9
402432016-06-29 13:39:39.225rhenriques4.54.7575EB ON, V=+175V / cycles: 1,4,6; FRAEP stopped earlier than usual (during discharge)
402422016-06-29 13:25:30.573rhenriques4.54.6125repeat previous (HIBD beam OFF) / cycles: 1,3,5,7,9
402412016-06-29 13:20:06.062rhenriques4.54.5125EB OFF / cycles: 1,3,5,7,9
402402016-06-29 13:12:27.584rhenriques4.54.6125EB ON, V=+200V / cycles: 1,3,5,7,9
402392016-06-29 12:58:52.792rhenriques4.55125EB ON, V=+175V / cycles: 1,2,4,6,8
402382016-06-29 12:52:07.989rhenriques4.55125repeat previous / cycles: 1,2,4,6,8
402372016-06-29 11:36:03.175rhenriques4.54.5100EB ON, V=+150V, Ton=[23.5 to 25]ms / cycles: 1,4,7,9
402362016-06-29 11:29:59.417rhenriques4.54.5125repeat previous; reference shot; EB OFF / cycles:
402352016-06-29 11:24:36.721rhenriques000repeat previous; 10 semi-cycles / GetData: h(=0) different from master h (=-5619712)
402342016-06-29 11:19:00.314rhenriques4.54.575EB OFF; reference shot / cycles: 1,3,5
402332016-06-29 11:10:32.073rhenriques4.54.575EB ON / cycles:1,3,5; OK
402322016-06-29 11:03:51.534rhenriques4.54.675EB OFF; HIBD ON; reference shot / cycles: 1,3,5; OK
402312016-06-29 10:47:07.434rhenriques4.54.775repeat previous with corrections / cycles: 1,3,5; HIBD modulation was OFF in all previous shots (trigger amplitude was too low for switching)
402302016-06-29 10:41:47.563rhenriques4.54.575repeat 40228 because 50Hz modulation on HIBD was ON / cycles: 1,3,5; HIBD amplifiers were OFF
402292016-06-29 10:36:08.405rhenriques4.54.675EB ON, HIBD ON, E=23.5keV, Vx=235V, Vy=493V, fmod=180kHz /
402282016-06-29 10:27:39.319rhenriques4.54.675repeat previous with corrections / cycles: 1,3,5
402272016-06-29 10:21:15.277rhenriques4.54.625EB OFF for reference / cycles: 2; HIBD was OFF; EB was ON
402262016-06-29 10:10:40.795rhenriques4.54.575EB ON, V=-150V / cycles: 1,3,5
402252016-06-29 09:57:55.686rhenriques4.54.7550rake @ r=65mm; EB ON, V=-100V / cycles: 2,6
402242016-06-29 09:50:09.268rhenriques4.54.7575EB ON, V=-50V / cycles: 1,3,5
402232016-06-29 09:43:04.929rhenriques4.5575EB ON, V=-20V / cycles: 2,4,6
402222016-06-29 09:25:53.411rhenriques4.54.875conditioning; EB ON, V=+100V, Ton=[18.5 to 19.5]ms / cycles: 1,3,5
402212016-06-29 09:20:01.193rhenriques4.5575conditioning; rake probe (Vf) @r=60mm (B1.ch32,31,30,29,27,26,25,16,15); 2D @85mm (3Vf+1Isat for turbulent transport: B1.ch14,12,11 + B1.ch13); EB(OFF) @r=70mm; HIBD(OFF) / cycles: 1,3,6
402202016-06-29 09:05:50.723rhenriques4.54.575conditioning discharge (repeat of 40219 without diagnostics inside) / cycles: 1,3,5; everything OK