Shot
|
Time
|
Operator
|
Iplasma(kA)
|
n(1018m-3)
|
Duration (ms)
|
Pre/post shot comments
|
| 51621 | 2024-12-19 20:02:52.223 | rhenriques | 0 | 0 | 0 | Repeat (Iprim on B3ch2 and Vprim on B3ch1) with longer ON time of 13 ms | OK, current shoots up after iron core saturation |
| 51620 | 2024-12-19 19:47:48.981 | fernando | 0 | 0 | 0 | Repeat with capacitor bank voltage at 200 V, with 10 ms long | OK, iron core almost started to saturate |
| 51619 | 2024-12-19 19:35:14.713 | rhenriques | 0 | 0 | 0 | Repeat (primary bank voltage programmed for 60 V) | OK, but current in primary very low as expected... |
| 51618 | 2024-12-19 19:06:10.616 | rhenriques | 0 | 0 | 0 | Primary PF coil with 10 ms always ON | no current in Primary, probably MARTe was not loaded with new config |
| 51617 | 2024-12-19 18:38:49.272 | rhenriques | 0 | 0 | 0 | Repeat previous (Iv on B3ch3 and Vv on B3ch7) | OK, satuaration reached at 113 A |
| 51616 | 2024-12-19 18:34:34.18 | fernando | 0 | 0 | 0 | Repeat previous with 13 ms flatopt | MARTe problem, no currents on the coils |
| 51615 | 2024-12-19 18:24:48.369 | rhenriques | 0 | 0 | 0 | Repeat with lower power supply voltage (12 V) to aim a saturation a avoid switching | OK, but never saturates |
| 51614 | 2024-12-19 17:44:52.303 | fernando | 0 | 0 | 0 | Repeat previous | OK, reach 200 A quite early starts switching |
| 51613 | 2024-12-19 17:37:22.485 | rhenriques | 0 | 0 | 0 | Vertical PF coil with 5 ms always ON | MARTe failed |
| 51612 | 2024-12-19 17:15:50.605 | rhenriques | 0 | 0 | 0 | Horizontal PF coil (Ih on B3ch4 and Vh on B3ch8) with 13 ms always ON | OK, almost constant at the end |
| 51611 | 2024-12-19 16:55:54.92 | rhenriques | 0 | 0 | 0 | calibration of B3 ch4 and ch8 with +/-2V, no current on PF coils | |
| 51610 | 2024-12-19 16:30:37.616 | rhenriques | 0 | 0 | 0 | chopper modules MARTe1 ATCA connected to pickup coils, B3 ch1 and ch3 with +/-2V reference waveform for calibration | OK |
| 51609 | 2024-12-19 15:43:52.866 | rhenriques | 0 | 0 | 0 | Chopper modules of MARTe 1 ATCA crate with +/- 2V square signal (30ms period) and same signal in B3 ch2 and ch7 for calibration, magnetic signals acquires by ATCA2 chopper modules | |