| Session aim | Dry runs for PF coil I-V characterization tests | | Session day | 2024-12-02 | Operator | fernando | | Session ID | ISTTOK_2024122_1 | Coordinator | rhenriques |
|
Shot
|
Time
|
Operator
|
Iplasma(kA)
|
n(1018m-3)
|
Duration (ms)
|
Pre/post shot comments
|
| 51584 | 2024-12-02 19:18:29.311 | rhenriques | 0 | 0 | 0 | Repeat previous with longer pulse (6 ms) hoping to get Ih flat and with vertcial PF coil open (disconnected from power supply) | OK, Ih still not reaching constant value (flat top) | | 51583 | 2024-12-02 18:55:02.86 | rhenriques | 0 | 0 | 0 | Repeat 51580 with battery charger disconnected; ADC converstion factors corrected | OK, Ih never gets flat (may be due to LEM acq. circuit filtering?) | | 51582 | 2024-12-02 18:46:20.885 | fernando | 0 | 0 | 0 | Repeat 51580 with battery charger disconnected; ADC converstion factors corrected | MARTe crashed, no current in PF coil | | 51581 | 2024-12-02 18:21:17.618 | fernando | 0 | 0 | 0 | Test acquisition channels of B3 to check which ones are +/-5V and which are +/-10V | ch. 1, 7, 8 are +/-10V; ch. 2, 3, 4 are +/-5V | | 51580 | 2024-12-02 17:58:01.55 | fernando | 0 | 0 | 0 | Horizontal only; Vv, Vh, Iv, Ih, Vp, Ip acquired in 2MS/s B3 chs. 1, 2, 3, 4, 7 and 8, respectively | Ih with very slow ramp, too slow to be real. Wrong ADC conversion factors in 3, 4, 7 and 8. |
|