|
Shot
|
Time
|
Operator
|
Iplasma(kA)
|
n(1018m-3)
|
Duration (ms)
|
Pre/post shot comments
|
| 51895 | 2025-03-06 20:42:38.166 | rhenriques | 0.834 | 0 | 0 | Repeat | OK |
| 51894 | 2025-03-06 20:38:08.906 | rhenriques | 0.818 | 0 | 0 | Repeat | OK |
| 51893 | 2025-03-06 20:34:06.718 | rhenriques | -0.81 | 0 | 0 | Repeat | OK |
| 51892 | 2025-03-06 20:27:41.444 | rhenriques | 0.782 | 0 | 0 | Repeat for comparison | OK |
| 51891 | 2025-03-06 20:22:27.768 | rhenriques | 0.769 | 0 | 0 | Repeat previous | OK |
| 51890 | 2025-03-06 20:18:27.932 | rhenriques | 0 | 0 | 0 | Repeat with reduced spectrometer gain (80) and longer integration time (500, instead of typical 200 ms) | MARTe failed |
| 51889 | 2025-03-06 20:14:29.808 | rhenriques | 0.75 | 0 | 0 | Repeat with reduced spectrometer gain (20) and longer integration time (500, instead of typical 200 ms) | OK, with longer integration time we see more lines (which may appear towards end of pulse) |
| 51888 | 2025-03-06 20:09:56.011 | rhenriques | 0.748 | 0 | 0 | Repeat with reduced spectrometer gain (40) and longer integration time (500, instead of typical 200 ms) | OK |
| 51887 | 2025-03-06 20:05:48.992 | rhenriques | 0.736 | 0 | 0 | Repeat with reduced spectrometer gain (50) and longer integration time (500, instead of typical 200 ms) | OK, interesting data on spectrometer |
| 51886 | 2025-03-06 19:59:05.295 | rhenriques | 0.736 | 0 | 0 | Repeat with reduced spectrometer gain (1) and integration time (40, insteado of typical 200 ms) | OK |
| 51885 | 2025-03-06 19:54:13.995 | rhenriques | 0 | 0 | 0 | Repeat with reduced spectrometer gain (1) | OK |
| 51884 | 2025-03-06 19:50:09.302 | rhenriques | 0 | 0 | 0 | Repeat with reduced spectrometer gain (10) | OK |
| 51883 | 2025-03-06 19:45:35.226 | rhenriques | 0.687 | 0 | 0 | Repeat with reduced spectrometer gain (50) | OK, but Halpha line still saturates |
| 51882 | 2025-03-06 19:40:45.71 | rhenriques | 0.672 | 0 | 0 | Repeat | OK, spectrometer data different than previous |
| 51881 | 2025-03-06 19:35:26.475 | rhenriques | 0.82 | 0 | 0 | Repeat | prefill was much lower |
| 51880 | 2025-03-06 19:30:41.296 | rhenriques | 0.665 | 0 | 0 | Repeat | OK |
| 51879 | 2025-03-06 19:26:18.357 | rhenriques | 0.647 | 0 | 0 | Repeat | No clear conclusions but some evolution is obsereved on spectrometer data |
| 51878 | 2025-03-06 19:21:35.804 | rhenriques | 0.638 | 0 | 0 | Repeat | Mostly the same but data from spectrometer looks different |
| 51877 | 2025-03-06 19:17:14.705 | rhenriques | 0.645 | 0 | 0 | Repeat with 20 semi-cycles to assess conditioning improvements | OK |
| 51876 | 2025-03-06 18:46:33.648 | rhenriques | 0.614 | 0 | 0 | Repeat with adjustment on horizontal field for Ip>0 | Different but not necessary better |
| 51875 | 2025-03-06 18:37:22.378 | rhenriques | 0 | 0 | 0 | Repeat with changes on Bv for Ip>0 | better flatop |
| 51874 | 2025-03-06 18:23:35.934 | rhenriques | 784 | 0 | 0 | Repeat with further adjustments on Bh for Ip > 0 | Slightly better |
| 51873 | 2025-03-06 18:18:19.741 | rhenriques | 0.724 | 0 | 0 | Repeat with correction on Bh for Ip > 0 only | Better but still far from centered position |
| 51872 | 2025-03-06 18:11:50.677 | rhenriques | -0.529 | 0 | 0 | Repeat with adjustment on horizontal field for both Ip (+ and -) | negative cycle better and positive cycle worst |
| 51871 | 2025-03-06 17:59:50.12 | rhenriques | -0.523 | 0 | 0 | Repeat with ajustments to waveforms for Ip>0 | Got all cycles but at rather lower current |
| 51870 | 2025-03-06 17:48:21.627 | rhenriques | -0.724 | 0 | 0 | Repeat 51868 | Better than reference, prefill slightly lower |
| 51869 | 2025-03-06 17:32:57.15 | rhenriques | 0 | 0 | 0 | Dryrun to check magnetic diagnostics and time base delay of MARTe signals | MARTe timebase delay is now back to normal value (-1 ms), no signals on Magnetics |
| 51868 | 2025-03-06 14:33:32.902 | rhenriques | -0.7 | 0 | 0 | Repeat | Higher prefill than previous pulses |
| 51867 | 2025-03-06 14:28:47.419 | rhenriques | -0.774 | 0 | 0 | Repeat aiming prefill level closer to reference | Much better, almost as reference |
| 51866 | 2025-03-06 14:20:17.083 | rhenriques | -0.34 | 0 | 0 | Repeat 51855 to assess plasma condition | Only got 2 negetive semi-cycles, prefill was significantly lower than in reference pulse |
| 51865 | 2025-03-06 14:07:53.418 | rhenriques | 0 | 0 | 0 | Dryrun (file: dryrun_standard_2025_03_03_51819.cfg) | PF and TF currents OK |