Shot
|
Time
|
Operator
|
Iplasma(kA)
|
n(1018m-3)
|
Duration (ms)
|
Pre/post shot comments
|
| 51925 | 2025-03-10 19:26:56.466 | rhenriques | -0.93 | 0 | 0 | Repeat with further changes | transition to Ip>0 are slightly better |
| 51924 | 2025-03-10 19:19:32.693 | rhenriques | -0.89 | 0 | 0 | Repeat with further changes | still not as good as reference |
| 51923 | 2025-03-10 19:12:55.604 | rhenriques | 0.88 | 0 | 0 | Repeat with changes in opposite direction | stil worse than 51921 |
| 51922 | 2025-03-10 19:04:14.16 | rhenriques | -0.9 | 0 | 0 | Repeat previous with changes to improve transition to Ip>0 | Made it worse |
| 51921 | 2025-03-10 18:47:39.208 | rhenriques | 0.864 | 0 | 0 | Repeat after checking interferometer PLL | It worked, density is back |
| 51920 | 2025-03-10 18:32:11.087 | rhenriques | -0.89 | 0 | 0 | Repeat to check density signal | Still not there |
| 51919 | 2025-03-10 18:19:38.323 | rhenriques | 0.83 | 0 | 0 | Repeat without changes | OK, density signal is wrong, sine and cosine have low signal |
| 51918 | 2025-03-10 17:48:20.905 | rhenriques | 0.84 | 0 | 0 | Repeat with different gain on channel B (clockwise rotation) to reduce elipticity | No clear changes |
| 51917 | 2025-03-10 17:37:25.955 | rhenriques | -0.82 | 0 | 0 | Repeat trying to centre channel A and offseting channel B downwards (on the oscilloscope) | Relatively well centred |
| 51916 | 2025-03-10 17:26:23.911 | rhenriques | -0.81 | 0 | 0 | Repeat with offset changed towards the left side (on oscilloscope) for channel A in interferometer | OK, central position changed |
| 51915 | 2025-03-10 16:49:59.809 | rhenriques | -0.89 | 0 | 0 | Repeat with different sine and cosine starting angles | Good, sine amplitude seems to be higher than cosine |
| 51914 | 2025-03-10 16:13:29.932 | rhenriques | -0.89 | 0 | 0 | Repeat with sine and cosine cables swapped | OK |
| 51913 | 2025-03-10 15:57:51.259 | rhenriques | -0.85 | 0 | 0 | Repeat plasma pulse 51908 to test interferometer | OK, but signal is negative |
| 51912 | 2025-03-10 11:24:41.817 | rhenriques | 0 | 0 | 0 | Repeat with gain=100 and integration_time=500 ms | OK |
| 51911 | 2025-03-10 11:20:43.077 | rhenriques | 0 | 0 | 0 | Repeat with gain=10 and integration_time=500 ms | OK |
| 51910 | 2025-03-10 11:15:32.642 | rhenriques | 0 | 0 | 0 | Repeat with Hg lamp ON (lamp is located at fiber optic end, near tokamak), gain=1, integration_time=200 ms | OK, saturated lines |
| 51909 | 2025-03-10 11:10:07.127 | rhenriques | 0 | 0 | 0 | Informatic pulse to acquire black frame (background) for SARSPEC spectrometer | OK |
| 51908 | 2025-03-10 10:45:29.367 | rhenriques | 0.843 | 0 | 0 | Repeat aiming higher prefill and to check optical signal (which was disconnected from 2MSps board, only in MARTe now) | Optical signal is now back to normal amplitude, prefill slightly higher |
| 51907 | 2025-03-10 10:31:36.937 | rhenriques | 0.85 | 0 | 0 | Repeat, prefill was a bit low in previous pulse | prefill still low, but pulse is now more similar to reference, signal fibre_optic_with_filter is quite low (there is some problem with the signal) |
| 51906 | 2025-03-10 10:18:19.571 | rhenriques | 0.84 | 0 | 0 | Repeat plasma pulse 51904 for comparison | Relatively similar to reference, slightly worse on the last semi-cycles, forgot to arm spectrometer |
| 51905 | 2025-03-10 10:07:07.74 | rhenriques | 0 | 0 | 0 | Dryrun (file: dryrun_standard_2025_03_03_51819.cfg) | PF and TF currents OK |