Shot
|
Time
|
Operator
|
Iplasma(kA)
|
n(1018m-3)
|
Duration (ms)
|
Pre/post shot comments
|
| 52007 | 2025-03-25 19:15:38.746 | rhenriques | -0.89 | 3.28 | 17 | Repeat with reduced spectrometer gain (40->20) and changes in Bv of Ip<0 transition | Better transition, spectrometer still saturates oxigen line |
| 52006 | 2025-03-25 18:59:05.441 | rhenriques | -0.923 | 3.24 | 17 | Repeat with 20 semi-cycles | OK, oxigen line on spectrometer saturated |
| 52005 | 2025-03-25 18:52:45.959 | rhenriques | -0.89 | 3.24 | 17 | Repeat with further adjustments on Bv for Ip>0 | better position |
| 52004 | 2025-03-25 18:47:02.596 | rhenriques | 0.761 | 3.59 | 17 | Repeat with changes on Ip>0 vertical field current to improve position | Better |
| 52003 | 2025-03-25 18:42:03.668 | rhenriques | 0.807 | 3.5 | 17 | Straight repeat | OK |
| 52002 | 2025-03-25 18:36:31.183 | rhenriques | 0.729 | 3.44 | 17 | Straight repeat | OK |
| 52001 | 2025-03-25 18:32:28.378 | rhenriques | 0.783 | 3.56 | 17 | Repeat with changes in the opposite direction | better transition |
| 52000 | 2025-03-25 18:26:58.823 | rhenriques | 0.751 | 3.39 | 17 | Repeat with changes in transtion to Ip > 0 | transition is worse |
| 51999 | 2025-03-25 18:20:50.461 | rhenriques | 0.734 | 3.38 | 17 | Repeat | OK |
| 51998 | 2025-03-25 18:15:21.65 | rhenriques | 0.744 | 3.28 | 17 | Repeat with 10 semicycles (+ 2) | OK |
| 51997 | 2025-03-25 18:04:52.82 | rhenriques | 0.743 | 3.27 | 17 | Repeat with further reduction of flattop duration (17 ms) | OK |
| 51996 | 2025-03-25 17:58:49.778 | rhenriques | 0.691 | 3.24 | 23 | Repeat with shorter flattop (20 ms maximum) | OK |
| 51995 | 2025-03-25 17:52:17.008 | rhenriques | 0 | 0 | 0 | Trying again | OK |
| 51994 | 2025-03-25 17:46:28.189 | rhenriques | 0 | 0 | 0 | Plasma pulse, repeat 51983 | MARTe did not received trigger/message to change state |
| 51993 | 2025-03-25 17:40:12.50 | rhenriques | 0 | 0 | 0 | Repeat with correct SARSPEC sprectrometer settings | OK |
| 51992 | 2025-03-25 17:32:38.219 | rhenriques | 0 | 0 | 0 | Dryrun (file: dryrun_standard_2025_03_18_51971.cfg) | Unusual settings for SARSPEC, PF and TF currents OK |
| 51991 | 2025-03-25 16:09:29.648 | rhenriques | 0 | 0 | 0 | Repeat with filament ON with 8.9 V, 0.59 A (strange that it gives the same current as in previous pulse) | OK |
| 51990 | 2025-03-25 16:00:59.895 | rhenriques | 0 | 0 | 0 | Repeat with filament ON with 11.36 V, 0.59 A | OK |
| 51989 | 2025-03-25 15:56:28.675 | rhenriques | 0 | 0 | 0 | Informatic pulse to acquire spectrum with SARSPEC spectrometer (POST.PROCESSED.TEST) of filament. Filamente is OFF, black frame for reference | OK |