Shot
|
Time
|
Operator
|
Iplasma(kA)
|
n(1018m-3)
|
Duration (ms)
|
Pre/post shot comments
|
| 52027 | 2025-03-26 18:57:23.402 | rhenriques | 1.26 | 3.28 | 17 | Repeat | OK |
| 52026 | 2025-03-26 18:52:08.839 | rhenriques | 1.4 | 3.34 | 17 | Repeat | lower prefill pressure and much higher current at first semi-cycle, then mostly the same |
| 52025 | 2025-03-26 18:43:54.735 | rhenriques | -1.05 | 3.2 | 17 | Repeat with lower prefill aiming at higher plasma current | OK, large Ip in first cycle, then almost no difference |
| 52024 | 2025-03-26 18:30:49.059 | rhenriques | -1 | 3.2 | 17 | Repeat with lower prefill aiming at higher plasma current | OK, a bit more Ip |
| 52023 | 2025-03-26 18:14:48.338 | rhenriques | -0.93 | 3.26 | 17 | Repeat with filament voltage back to standard value approx. 11.5 V | OK, but prefill was already a bit lower than the other pulses |
| 52022 | 2025-03-26 18:02:08.134 | rhenriques | -0.93 | 3.25 | 17 | Straight repeat | OK |
| 52021 | 2025-03-26 17:57:59.721 | rhenriques | -0.91 | 3.19 | 17 | Straight repeat | OK, 1st semi-cycle is back |
| 52020 | 2025-03-26 17:53:56.829 | rhenriques | 0.8 | 3.36 | 17 | Repeat with filament voltage at approx. 7.5 V | No breakdown for 1st positive semicycle |
| 52019 | 2025-03-26 17:48:37.274 | rhenriques | -0.952 | 3.1 | 17 | Repeat with filament voltage at approx. 2.5 V | OK |
| 52018 | 2025-03-26 17:39:19.083 | rhenriques | -0.91 | 3.07 | 17 | Repeat to adjust prefill pressure | OK |
| 52017 | 2025-03-26 17:31:12.795 | rhenriques | -0.87 | 3.12 | 17 | Straight repeat | OK, but prefill gas was much higher, breakdown for 1st semi-cycle is back |
| 52016 | 2025-03-26 17:26:00.33 | rhenriques | -0.903 | 3.4 | 17 | Repeat with filament voltage at approx. 5.5 V | Breakdown of 1st positive cycle did not happened, started with negative cycle |
| 52015 | 2025-03-26 17:17:59.847 | rhenriques | -0.91 | 3.14 | 17 | Repeat for filament test: filament voltage at 0 V. Filamente voltage acquire in RT2_24 channel | OK, breakdown started later |
| 52014 | 2025-03-26 17:08:48.475 | rhenriques | -0.868 | 3.13 | 17 | Repeat for repeatability | Good |
| 52013 | 2025-03-26 17:04:15.087 | rhenriques | -0.907 | 3.08 | 17 | Repeat to check repeatability | OK |
| 52012 | 2025-03-26 16:49:38.032 | rhenriques | -0.935 | 3.1 | 17 | Repeat plasma pulse #52007 (20 semi-cycles) | OK |
| 52011 | 2025-03-26 14:35:26.859 | rhenriques | 0 | 0 | 0 | Repeat | OK |
| 52010 | 2025-03-26 14:09:52.402 | rhenriques | 0 | 0 | 0 | Repeat with TF and PF currents ON and all channels normally connected to the diagnostics (short removed) | OK |
| 52009 | 2025-03-26 13:34:20.996 | rhenriques | 0 | 0 | 0 | Repeat with new calibrations for all calibrated channels: RT1_25-32, RT2_9_16_17-28. All channels have input shorted (0 V) to test offset calibration | All seem OK |
| 52008 | 2025-03-26 11:56:01.567 | rhenriques | 0 | 0 | 0 | Dryrun (file: dryrun_standard_2025_03_26_52008.cfg), no TF or PF currents, test acquisition system (RT1_ch25-32) with new calibration | Forgot to update offset for RT1_26, other than that OK |