Session aimPulses for HIBD and plasma optimization
Session day2025-03-28Operatorrhenriques
Session IDISTTOK_20250328_1Coordinatorrhenriques

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
520732025-03-28 15:22:36.792rhenriques000Repeat | OK
520722025-03-28 15:18:41.364rhenriques000Repeat | OK
520712025-03-28 15:14:46.911rhenriques000Repeat | OK
520702025-03-28 15:10:43.951rhenriques000Repeat | OK
520692025-03-28 15:06:12.375rhenriques000Repeat | OK
520682025-03-28 15:02:16.275rhenriques000Repeat | Data not acquired and no plasma
520672025-03-28 14:58:13.166rhenriques000Repeat | OK
520662025-03-28 14:54:06.202rhenriques000Repeat | OK
520652025-03-28 14:42:27.717rhenriques000Repeat | OK
520642025-03-28 14:37:46.316rhenriques-0.9553.5517Repeat with fewer semi-cycles (back to 20) | OK
520632025-03-28 14:01:43.174rhenriques-0.943.5317Repeat | OK
520622025-03-28 13:56:43.405rhenriques-0.8633.617Repeat | OK
520612025-03-28 13:46:01.583rhenriques-1.023.617Repeat | OK
520602025-03-28 13:41:54.244rhenriques-1.073.5617Repeat after lunch time which allowed for longer pumping and lower background pressure before the pulse | OK, slightly higher Ip than previous
520592025-03-28 11:04:45.163rhenriques-0.9723.517Repeat | OK
520582025-03-28 10:59:04.424rhenriques-0.9933.4617Repeat | OK
520572025-03-28 10:51:53.718rhenriques-1.0143.3917Repeat | OK
520562025-03-28 10:42:10.495rhenriques-13.3317Repeat | Mostly the same as in previous
520552025-03-28 10:36:54.098rhenriques-13.3817Straight repeat for comparison with previous | very similar to previous
520542025-03-28 10:22:50.025rhenriques-1.0123.4417Repeat with 50 semi-cycles | OK
520532025-03-28 10:09:44.077rhenriques-1.0253.4617Repeat with 45 semi-cycles and Spectrometer SARSPEC integration time of 1000 ms | OK
520522025-03-28 10:02:41.18rhenriques-1.0923.5217Repeat with 40 semy-cycles | All cycles successfull
520512025-03-28 09:47:48.465rhenriques-1.1363.6517Repeat 52027 with normal gas pressure for prefill approx. 1e-4 mBar | OK, better pulse than reference, there are signs of improvements
520502025-03-28 09:38:28.485rhenriques000Dryrun (file: dryrun_standard_2025_03_26_52008.cfg) | PF and TF currents OK