Shot
|
Time
|
Operator
|
Iplasma(kA)
|
n(1018m-3)
|
Duration (ms)
|
Pre/post shot comments
|
| 52160 | 2025-04-08 09:55:14.22 | rhenriques | 0 | 0 | 0 | Dryrun (file: dryrun_standard_2025_04_04_52149.cfg) no PF/TF | OK, sound alert during countdown did not worked |
| 52159 | 2025-04-04 16:05:22.299 | rhenriques | 0 | 3.91 | 17 | Repeat | Still the same... |
| 52158 | 2025-04-04 16:01:18.439 | rhenriques | 0 | 0 | 0 | Repeat to check if there are improvements | Failure, pulse aborted |
| 52157 | 2025-04-04 15:54:32.133 | rhenriques | -1.28 | 3.88 | 17 | Plasma pulse, repeat 52132 | Not good, some semi-cycles failed towards the end |
| 52156 | 2025-04-04 15:40:07.37 | rhenriques | 0 | 0 | 0 | Repeat after tightening all coil contacts | OK |
| 52155 | 2025-04-04 12:35:32.724 | rhenriques | 0 | 0 | 0 | Repeat without TF | OK |
| 52154 | 2025-04-04 12:11:13.818 | rhenriques | 0 | 0 | 0 | Repeat dryrun with PF and TF ON | Something strange happened with the vertical field current, needs investigation |
| 52153 | 2025-04-04 11:00:16.261 | rhenriques | 0 | 0 | 0 | Repeat with cable to tokamak connected for EO calculations | OK but coil no. 10 seems to be noisy |
| 52152 | 2025-04-04 10:46:55.181 | rhenriques | 0 | 0 | 0 | Repeat after swaping module 11 with 13 | All OK |
| 52151 | 2025-04-04 10:25:43.897 | rhenriques | 0 | 0 | 0 | Repeat, this time to check Magnetics acquistion channel directly (without cable to tokamak) with same signal | ch.11 still not working |
| 52150 | 2025-04-04 10:12:28.43 | rhenriques | 0 | 0 | 0 | Repeat to double check PS voltage measurements, Magnetics cable with square wave 8.5 Hz 530 mVpp for acquisition channel testing | OK, ch.11 not receiving signal |
| 52149 | 2025-04-04 09:42:17.371 | rhenriques | 0 | 0 | 0 | Dryrun NEW (file: dryrun_standard_2025_04_04_52149.cfg) with modified waveforms to check Vhorz and Vvert power supply performance, Vhorz and Vvert now acquired in MARTe as well, no PF/TF | OK |