Session aimTest new standard dryrun, check Magnetics and then plasma
Session day2025-04-04Operatorrhenriques
Session IDISTTOK_20250404_1Coordinatorrhenriques

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
521602025-04-08 09:55:14.22rhenriques000Dryrun (file: dryrun_standard_2025_04_04_52149.cfg) no PF/TF | OK, sound alert during countdown did not worked
521592025-04-04 16:05:22.299rhenriques03.9117Repeat | Still the same...
521582025-04-04 16:01:18.439rhenriques000Repeat to check if there are improvements | Failure, pulse aborted
521572025-04-04 15:54:32.133rhenriques-1.283.8817Plasma pulse, repeat 52132 | Not good, some semi-cycles failed towards the end
521562025-04-04 15:40:07.37rhenriques000Repeat after tightening all coil contacts | OK
521552025-04-04 12:35:32.724rhenriques000Repeat without TF | OK
521542025-04-04 12:11:13.818rhenriques000Repeat dryrun with PF and TF ON | Something strange happened with the vertical field current, needs investigation
521532025-04-04 11:00:16.261rhenriques000Repeat with cable to tokamak connected for EO calculations | OK but coil no. 10 seems to be noisy
521522025-04-04 10:46:55.181rhenriques000Repeat after swaping module 11 with 13 | All OK
521512025-04-04 10:25:43.897rhenriques000Repeat, this time to check Magnetics acquistion channel directly (without cable to tokamak) with same signal | ch.11 still not working
521502025-04-04 10:12:28.43rhenriques000Repeat to double check PS voltage measurements, Magnetics cable with square wave 8.5 Hz 530 mVpp for acquisition channel testing | OK, ch.11 not receiving signal
521492025-04-04 09:42:17.371rhenriques000Dryrun NEW (file: dryrun_standard_2025_04_04_52149.cfg) with modified waveforms to check Vhorz and Vvert power supply performance, Vhorz and Vvert now acquired in MARTe as well, no PF/TF | OK