Shot
|
Time
|
Operator
|
Iplasma(kA)
|
n(1018m-3)
|
Duration (ms)
|
Pre/post shot comments
|
| 52251 | 2025-04-10 18:24:29.533 | rhenriques | -1.38 | 3.8 | 17 | Repeat at higher prefill pressure ~1e-4 mBar | OK |
| 52250 | 2025-04-10 18:20:31.448 | rhenriques | -1.465 | 3.89 | 17 | Repeat | OK |
| 52249 | 2025-04-10 18:16:17.876 | rhenriques | -1.475 | 3.81 | 17 | Repeat | OK |
| 52248 | 2025-04-10 18:12:11.92 | rhenriques | -1.446 | 3.84 | 17 | Repeat | OK |
| 52247 | 2025-04-10 18:07:35.291 | rhenriques | -1.496 | 3.93 | 17 | Repeat with signals back to their original position | OK, signals are OK |
| 52246 | 2025-04-10 17:59:19.611 | rhenriques | -1.446 | 3.8 | 17 | Repeat, swap fiber_optic_with_filter with photodiode_visible signal at acquisition channels to check the fiber one which suddenly lost a lot of amplitude | Both signals have the correct amplitude |
| 52245 | 2025-04-10 17:46:04.207 | rhenriques | -1.41 | 3.6 | 17 | Repeat | OK |
| 52244 | 2025-04-10 17:41:33.97 | rhenriques | -1.488 | 3.86 | 17 | Repeat | OK |
| 52243 | 2025-04-10 17:33:07.354 | rhenriques | -1.464 | 3.9 | 17 | Repeat with lower prefill (as in reference pulse) | OK |
| 52242 | 2025-04-10 17:26:58.671 | rhenriques | -1.304 | 3.62 | 17 | Repeat | OK |
| 52241 | 2025-04-10 17:18:45.439 | rhenriques | -1.28 | 3.7 | 17 | Plasma pulse, repat 52232 with normal prefill pressure ~1e-4 mBar | OK, signal from fiber_optic_with_filter (O I line) is significantly lower than reference pulse |
| 52240 | 2025-04-10 17:10:47.934 | rhenriques | 0 | 0 | 0 | Repeat with cables back to normal position and after having fiddled with the module | Looks better but it is still more noisy than the other ones |
| 52239 | 2025-04-10 16:49:36.712 | rhenriques | 0 | 0 | 0 | Repeat, connecting back to 2nd ATCA and swaping cable in MARTe 1 ATCA: coil no. 1-8 to RT3_9-17 and 9-12 to RT3_25-28 | Noise comes from the integrator module |
| 52238 | 2025-04-10 16:41:03.663 | rhenriques | 0 | 0 | 0 | Repeat with connection to 2nd ATCA (MARTe 2) crate module removed | Did not improve |
| 52237 | 2025-04-10 16:32:57.218 | rhenriques | 0 | 0 | 0 | Repeat to check if coil no. 2 signal is less noisy after cable checking. Request of 300 A | Better but coil no. 2 is still noisy |
| 52236 | 2025-04-10 16:21:22.336 | rhenriques | 0 | 0 | 0 | Repeat with lower request (280 A) | Good, signal of coil no. 2 is noisy |
| 52235 | 2025-04-10 16:14:22.559 | rhenriques | 0 | 0 | 0 | Special dryrun with long Vertical PF current only, for Magnetics diagnostics calibrations | OK, but current never reaches the request and keeps decreasing throughout the pulse |
| 52234 | 2025-04-10 16:08:04.364 | rhenriques | 0 | 0 | 0 | Repeat with lower request (100 A) | Good |
| 52233 | 2025-04-10 15:58:31.629 | rhenriques | 0 | 0 | 0 | Special dryrun with long Horizontal PF current only, for Magnetics diagnostics calibrations | Good, did not reach the request (200) but was quite stable |