Session aimContinue with plasma pulses for conditioning
Session day2025-04-16Operatorrhenriques
Session IDISTTOK_20250416_1Coordinatorrhenriques

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
523492025-04-16 16:29:20.044rhenriques000Repeat with positive polarization again | stopped early again
523482025-04-16 16:25:13.568rhenriques000Repeat with negative polarization | stopped early again
523472025-04-16 16:19:54.621rhenriques000Repeat with 0.5 long waveform | stopped very early, not sure why
523462025-04-16 16:13:53.411rhenriques000Same repeat to check iron core magnetization | OK
523452025-04-16 16:00:44.623rhenriques000Repeat with increased limit thresholds | OK, but current did not reach target as waveform ended before
523442025-04-16 15:49:01.962rhenriques000Repeat with iron core saturation limits increased | Changed on limits was not loaded properly
523432025-04-16 15:41:40.283rhenriques000Repeat with 100 ms long waveform | stopped due to iron core saturation limit, the previous also did
523422025-04-16 15:34:16.036rhenriques000Special dryrun with Primary current only for calibration and test of Magnetic pickup coils, short waveform for initial testing (10 ms only) | OK, Iprim reached 27.5 A but it was still rising
523412025-04-16 13:57:45.469rhenriques1.33.720Repeat with 20 semi-cycles | Better, but still not good there were still failed cycle
523402025-04-16 13:50:01.628rhenriques1.3320Repeat with expected changes | OK, but severla cycles failed, mostly positive ones
523392025-04-16 13:14:41.402rhenriques1.34.3517Repeat with fewer cycles until all cycles are back. Start increasing the length of the discharge (20 ms) | Forgot to load changes, so configuration was the same as in previous pulse. 2 semi-cyc failed
523382025-04-16 13:04:32.899rhenriques1.33.117Repeat | Almost all positive cycles failed
523372025-04-16 12:36:21.617rhenriques1.34.517Plasma pulse, repeat 52332 | Many semi-cycle failed
523362025-04-16 12:25:50.539rhenriques000Repeat with some of the Magnetic pickup coils also connected to B3: coil no. 3,6,9 and 12 to chs. 25, 26, 27 and 28 | OK, only WO seems to be affected
523352025-04-16 12:09:19.638rhenriques000Dryrun (file: dryrun_standard_2025_04_04_52149.cfg), no TF, only PF currents | PF currents OK, forgot to arm spectrometer