Shot
|
Time
|
Operator
|
Iplasma(kA)
|
n(1018m-3)
|
Duration (ms)
|
Pre/post shot comments
|
| 52375 | 2025-04-17 14:19:01.102 | rhenriques | 0 | 0 | 0 | Repeat 50 A (with 60 V) | Good |
| 52374 | 2025-04-17 14:13:31.128 | rhenriques | 0 | 0 | 0 | Repeat requesting 200 A (still with 100 V) | Good |
| 52373 | 2025-04-17 14:09:05.347 | rhenriques | 0 | 0 | 0 | Repeat requesting 100 A (still with 80 V) | Good |
| 52372 | 2025-04-17 13:56:36.742 | rhenriques | 0 | 0 | 0 | Repeat (150 A) with increased capacitor bank voltage to 80 V (was 60 V) | Good |
| 52371 | 2025-04-17 13:44:27.274 | rhenriques | 0 | 0 | 0 | Repeat with 500 ms long | OK, good but Primary voltage not enought to guarantee full length of waveform |
| 52370 | 2025-04-17 13:34:27.511 | rhenriques | 0 | 0 | 0 | Repeat with lower resistance at the secondary circuit | Good, current raises much faster |
| 52369 | 2025-04-17 13:24:10.513 | rhenriques | 0 | 0 | 0 | Special dryrun with Primary current only for calibration and test of Magnetic pickup coils, short waveform for initial testing (100 ms only), repeat 52344 | Never reach requested current |
| 52368 | 2025-04-17 11:17:06.008 | rhenriques | 1.3 | 3.4 | 26 | Repeat with 14 cycles instead of 10 | 1 cycle failed and transition to Ip>0 is still not good |
| 52367 | 2025-04-17 11:11:28.901 | rhenriques | 1.3 | 3.1 | 26 | Repeat extending to 26 ms and tweaking Bv of Ip<0 back to improve transitions | one cycle failed |
| 52366 | 2025-04-17 10:28:01.378 | rhenriques | 1.3 | 3.4 | 24 | Repeat with adjustments on Bv of Ip<0 for better plasma position | some cycles still failed, position is a bit better |
| 52365 | 2025-04-17 10:09:44.88 | rhenriques | 1.3 | 3 | 24 | Repeat with adjustments on Bv of Ip<0 and extending cycle length to 24 ms | better, primary current does not saturate |
| 52364 | 2025-04-17 09:55:18.878 | rhenriques | 1.3 | 3.2 | 22 | Straight repeat | different results than previous |
| 52363 | 2025-04-17 09:48:33.045 | rhenriques | 1.3 | 3.45 | 22 | Repeat with changes on Bv for Ip<0, trying to improve transition to Ip>0 | slightly better but still nees improvements |
| 52362 | 2025-04-17 09:37:57.358 | rhenriques | 1.3 | 3.3 | 22 | Repeat with changes on Bv for Ip>0, to impove transitions to Ip<0 | Beter transition to Ip<0 just after 1st semi-cycle, transition to Ip>0 not so successful |
| 52361 | 2025-04-17 09:27:01.156 | rhenriques | 1.3 | 3.7 | 22 | Repeat with small change on Bv for Ip<0 aiming to improve transitions to Ip>0 | All positive and only the 2 last negative |
| 52360 | 2025-04-17 09:15:54.062 | rhenriques | 1.3 | 3.2 | 22 | Straight repeat | Same result |
| 52359 | 2025-04-17 08:59:33.55 | rhenriques | 1.3 | 2.87 | 22 | Repeat extending cycle length to 22 ms and correcting position for negeative cycles | Iron core did not saturate, 1st positive and then only negative semi-cycles |
| 52358 | 2025-04-17 08:42:41.821 | rhenriques | 1.3 | 3.9 | 20 | Going back to low current and long pulses for conditioning, repeat 52340 aiming on getting cycles longer (20 ms) | Iron core does not saturate, negative cycles seems to be quite off centered |
| 52357 | 2025-04-17 08:30:01.824 | rhenriques | -4.3 | 6.4 | 25 | Repeat just for comparison | Similar results as in previous pulse |
| 52356 | 2025-04-17 08:19:15.482 | rhenriques | -4.5 | 7.3 | 25 | Repeat | Not too bad, iron core saturates on the positive cycles and the negative ones are short-lived |
| 52355 | 2025-04-17 08:11:48.833 | rhenriques | 0 | 0 | 0 | Repeat 46241 (but with fewer cycles 40 -> 10), plasma is now full feedback controlled with magnetic pickup coils | Error on the configuration (PS TTY addresses were not loaded correctly), no plasma |
| 52354 | 2025-04-17 08:01:00.259 | rhenriques | 1.3 | 3 | 17 | Repeat | 9 semi-cycles failed (all the positive ones) |
| 52353 | 2025-04-17 07:54:57.162 | rhenriques | 1.3 | 4 | 17 | Straight repeat | 8 semi-cycles failed all positive |
| 52352 | 2025-04-17 07:49:27.038 | rhenriques | 1.3 | 4 | 17 | Repeat 52332 as starting point and for reference comparison | 5 semi-cycles failed (all negative) |
| 52351 | 2025-04-17 07:39:08.668 | rhenriques | 0 | 0 | 0 | Repeat with primary voltage (capacitor bank) back to nominal values ~260 V | Good |
| 52350 | 2025-04-17 07:31:15.497 | rhenriques | 0 | 0 | 0 | Dryrun (file: dryrun_standard_2025_04_04_52149.cfg) no TF, PF only, Primary with lower voltage ~60 V | OK, primary current lower than usual, as expected |