Shot
|
Time
|
Operator
|
Iplasma(kA)
|
n(1018m-3)
|
Duration (ms)
|
Pre/post shot comments
|
| 52487 | 2025-04-23 18:03:56.025 | rhenriques | 1.2 | 2.1 | 17 | Repeat with more negative Bv for BD | BD happens earlier but prefill pressure was also lower, not conclusive result |
| 52486 | 2025-04-23 17:59:37.173 | rhenriques | 1.2 | 2.3 | 17 | Repeat with same prefill pressure | back to the same as without premag |
| 52485 | 2025-04-23 17:53:35.136 | rhenriques | 1.2 | 2.4 | 17 | Repeat with different approach for BD Bv waveform | happens later but prefill pressure was much higher than references |
| 52484 | 2025-04-23 17:47:36.047 | rhenriques | 1.2 | 2.1 | 17 | Repeat with Bv tweaks for BD | No improvements |
| 52483 | 2025-04-23 17:38:41.837 | rhenriques | 1.2 | 2.1 | 17 | Try pulse without premag | BD happens later than previous ones |
| 52482 | 2025-04-23 17:28:57.887 | rhenriques | 1.2 | 2 | 17 | Repeat with changes on Bv for flattop | Worse than before |
| 52481 | 2025-04-23 17:20:53.767 | rhenriques | 1.2 | 3 | 17 | Repeat with Bv for Ip>0 flattop changes | Still not much better |
| 52480 | 2025-04-23 17:15:13.804 | rhenriques | 1.2 | 3 | 17 | Straight repeat to get similar premas as in previous pulses | Position drifts off to wrong side |
| 52479 | 2025-04-23 17:08:17.202 | rhenriques | 1.2 | 2.86 | 17 | Reverting changes for inversion, adjusting Bv during flattop of Ip>0 | premag state was different than previous pulses, harder to interpret |
| 52478 | 2025-04-23 16:59:46.131 | rhenriques | 1.2 | 2.8 | 17 | Further changes to see if it improves, trying also to get 1st inversion to Ip<0 | BD better but flattop worse, inversion to Ip<0 worse |
| 52477 | 2025-04-23 16:46:53.414 | rhenriques | 1.2 | 2.9 | 17 | Correction to Bv for BD and changes on Bv for early phase of cycle | Much better 1st cycle |
| 52476 | 2025-04-23 16:37:41.189 | rhenriques | 1.2 | 2.1 | 17 | Repeat with changes on Bv for BD | changes affectec Ip ramp up, no clear changes during flattop |
| 52475 | 2025-04-23 16:27:40.983 | rhenriques | 1.2 | 2.5 | 17 | Repeat with further adjustments on Bv Ip>0 | Better |
| 52474 | 2025-04-23 16:22:29.315 | rhenriques | 1.2 | 2.8 | 17 | Reverting Bv for Ip<0 changes, and changing Bv for Ip>0 with -20 A to get at least the 1st cycle reasonably centered | begining seems worse but ending seems slightly better |
| 52473 | 2025-04-23 16:16:18.238 | rhenriques | 1.2 | 3 | 17 | Repeat with Bv for Ip<0 with -10 A | Negative cycles are shorter |
| 52472 | 2025-04-23 16:08:00.496 | rhenriques | 1.2 | 3.37 | 17 | Repeat with further changes on Bv for Ip<0 (-10A) and Bv for Ip>0 (+10A) | Negative cycles are longer, no changes in position |
| 52471 | 2025-04-23 15:59:20.895 | rhenriques | 1.2 | 2.8 | 17 | Repeat changing Bv (-10 A in all waveform points) | negative cycles are slightly longer |
| 52470 | 2025-04-23 15:50:17.759 | rhenriques | 1.2 | 2.8 | 17 | Repeat trying to improve negative cycles first, Bh for flattop more negative | No clear changes observed |
| 52469 | 2025-04-23 12:13:11.018 | rhenriques | 1.2 | 0 | 17 | Repeat with Bv change into opposite direction | Still mostly the same, it needs a new equilibrium as previous one does not seem to be valid anymore |
| 52468 | 2025-04-23 12:07:52.427 | rhenriques | 1.2 | 0 | 17 | Repeat with adjusted primary current to get a more constant plasma current and increased Bv in inversion to Ip>0 | Bv change seems to have made it worse |
| 52467 | 2025-04-23 12:00:24.986 | rhenriques | 1.3 | 0 | 17 | Repeat with changes for improved BD | Much better BD, but the rest is mostly the same |
| 52466 | 2025-04-23 11:49:47.894 | rhenriques | 1.2 | 0 | 17 | Plasma for cleaning/conditioning repeat 52251 with limited Primary current and 20 cycles only | 1st cycle OK, then only negative short cycles |
| 52465 | 2025-04-23 11:26:10.761 | rhenriques | 4.3 | 0 | 26 | Repeat with Bv at -134.77 A | Mostly the same as in previous |
| 52464 | 2025-04-23 11:20:45.73 | rhenriques | 4.3 | 0 | 26 | Repeat with Bv at -137.7 A | prefill 1.05e-5 mBar, BD slightly earlier than previous |
| 52463 | 2025-04-23 11:13:48.972 | rhenriques | 4.3 | 0 | 26 | Going back to 52455 recipe and perform small tweaks, Bv for BD with -140.63 | prefill during pulse at MC was 1.06e-5 mBar |
| 52462 | 2025-04-23 11:04:30.332 | rhenriques | 4.3 | 0 | 26 | Repeat with Bv for BD changed to -100 A | BD happens significantly later |
| 52461 | 2025-04-23 10:59:54.955 | rhenriques | 4.2 | 0 | 26 | Repeat with Bv for BD changed to -125 A | BD happens earlier than previous but later than 52459 |
| 52460 | 2025-04-23 10:55:28.773 | rhenriques | 4.1 | 0 | 26 | Repeat aiming again at 9.5e-5 mBar at MC before pulse and changes on Bv for BD to improve | BD starts later |
| 52459 | 2025-04-23 10:49:15.347 | rhenriques | 4.3 | 0 | 26 | Repeat with prefill at 9.5e-5 mBar at MC before pulse to prevent HXRs | prefill befor pulse was 9.1e-5 mBar and measured one was 9.75 mBar, there is still tiny bit of HXR |
| 52458 | 2025-04-23 10:44:07.847 | rhenriques | 4.3 | 0 | 26 | Repeat with a bit less prefill pressure | Prefill on screen before pulse 8.7e-5 mBar at MC, measured during pulse 9.24e-5 mBar at MC |
| 52457 | 2025-04-23 10:39:08.425 | rhenriques | 4.35 | 0 | 26 | Repeat | No HXR observed, prefill measured at 9.7e-5 mBar while in display before pulse was 9.2e-5 mBar |
| 52456 | 2025-04-23 10:29:35.74 | rhenriques | 0 | 0 | 26 | Repeat with higher prefill pressure to prevent runaway electrons (HXRs) | Controller failed, no plasma |
| 52455 | 2025-04-23 09:25:21.679 | rhenriques | 4.7 | 0 | 26 | Repeat aiming same prefill as in 52448 (previous was a bit high) | Maximum current still lower than reference pulse but overall behaviour is similar |
| 52454 | 2025-04-23 09:15:12.141 | rhenriques | 4 | 0 | 26 | Repeat 52448 to assess conditioning changes (using prefill pressure as in reference ~6.5e-5 mBar) | Density signal not working, some plasma observed before BD, premag did not reach requested current |
| 52453 | 2025-04-23 09:02:30.851 | rhenriques | 0 | 0 | 0 | Dryrun (file: dryrun_standard_2025_04_04_52149.cfg) no TF | PF currents OK |